Att 2 SWMP
PRELIMINARY
NOT FOR CONSTRUCTION
100mm GRATED BIORETENTION GARDEN
TRENCH DRAIN
EXISTING TRENCH DRAIN
PROVIDE 7,500L SLIMLINE DRIVEWAY
RAINWATER ATTENUATION
TANKS AS PER DETAIL B.
RAINWATER TANK
OVERLAND FLOW DIRECTION
PROPOSED NEW
DRIVEWAY DRAINAGE LINE
PROPOSED
CARETAKERS
BUILDING
EXISTING
COVERED
5m² BIORETENTION AREA. BUILDING
CARETAKERS
CAR PARK 600MM FILTER MEDIA
200MM EXTENDED DETENTION DEPTH
REFER TO DETAIL A.
TANDEM CAR
PARK
STORM WATER PIT
APPROX STORM WATER LINE
PROVIDE 600x600 GRATED INLET
SMH CLASS B GRATED LID
APPROX SEWER LINE
SMH
EXTENDED DETENTION
NOMINAL 200MM
PLANTING SPECIES TO PROVIDE EFFECTIVE
REMOVAL OF NUTRIENTS. PLANT VARIETIES
MAINTENANCE HATCH AND PLANTING DENSITIES TO ARCHITECTURAL
SECURE CAPPED END WITH
SCREWS
SPECIFICATIONS
LOW FLOW JUNCTION WITH SCREW CAP DETAIL DO NOT SCALE, IF IN DOUBT ASK!
NTS
600x600 RAISED GRATE ORIFICE PLATE DISK WITH 100Ø HIGH FLOW OUTLET ROOF DOWNPIPE CONNECTION TO HYDRAULIC
FIELD INLET PIT S.L. 25mm ORIFICE ENGINEERS SPECIFICATIONS
1 IN
4 MA
X MAX HIGH FLOW
1 IN 4 EXTEND GEOFABRIC 500MM TANK WALL
OUTLET
AND PIN UNDER TOPSOIL
RETENTION LEVEL 7,500L SLIMLINE RAINWATER TANK
SCREW ON
500MM SANDY LOAM FILTER MEDIA ACCESS CAP
(0.45MM AVERAGE PARTICLE SIZE) ATTENUATION
VOLUME 3.75KL 0 8/10/21 INITIAL PREPARATION BP MP
Rev Date Description By Chk
OUTLET TO
DRAINAGE
NETWORK
100MM COARSE SAND TRANSITION ORIFICE DISK TO BE GLUED INSIDE RAINWATER REUSE VOLUME
FILTER MEDIA JUNCTION. uPVC OUTLET FROM TANK 3.75KL
(NOMINAL SIZE 0.5 - 2MM) TO BUTT UP AGAINST ORIFICE DISK
PROVIDE PROVIDE SLOTTED SUBSOIL DRAIN AT
END CAP MIN 0.5% GRADE TO PIT NOMINAL 200MM GRAVEL DRAINAGE LAYER [email protected]
(FINE AGG., NOMINAL SIZE 2 - 5MM)
37 MARY ST NOOSAVILLE, QLD
BIDIM A34 GEOFABRIC OR SIMILAR 07 5211 1003
SUBSOIL DRAIN CLEANOUT TO BE WRAPPED AROUND
WALLS AND BASE OF FILTER MEDIA
DETAIL B - RAINWATER ATTENUATION TANK Client
(NON-SLOTTED PVC) AND 135° ELBOW NTS RG STRATEGIC
CONNECTOR
Project Name
SCOOTER STYLE
16 RENE ST
DETAIL A -BIORETENTION AREA DRAINAGE NOTES SUBJECT STRUCTURE TO BE CONSTRUCTED TO.
7. CONTRACTOR TO ENSURE ALL MANHOLE AND PIT STRUCTURES COMPLY WITH THE MAXIMUM DEPTH SPECIFIED NOOSAVILLE 4566 QLD
NTS BY THE LOCAL AUTHORITY FROM FINISHED SURFACE LEVEL TO UNDERSIDE OF SLAB. ANY NON CONFORMANCE
1. BUILDING DRAINAGE TO BE DESIGNED BY HYDRAULIC CONSULTANT. Title
IS TO BE RECTIFIED AT THE CONTRACTORS EXPENSE.
2. ALL STORMWATER PIPES ARE TO BE MANUFACTURED TO RELEVANT AUSTRALIAN STANDARDS INCLUDING BUT PRELIMINARY STORMWATER LAYOUT
NOT LIMITED TO AS4058 AND AS1992. 8. THE CONTRACTOR IS TO CONFIRM THE LOCATION OF SERVICE CONDUITS WITH THE SUPERINTENDENT PRIOR
TO LAYING STORMWATER DRAINAGE. ALL TRENCH EXCAVATION AND CONSTRUCTION SHALL COMPLY WITH THE
3. CONTRACTOR TO CONFIRM LOCATION AND LEVEL OF EXISTING STORMWATER DRAINAGE WHERE CONNECTING REQUIREMENTS OF THE QUEENSLAND WORKPLACE HEALTH AND SAFETY ACT 2011.
ON TO EXISTING AND NOTIFY ENGINEER OF ANY CONFLICTS.
9. REFER TO ARCHITECTURAL PLANS FOR ALL DIMENSIONS.
4. ALL STORMWATER GRATES/LIDS WITHIN TRAFFICABLE AREAS TO BE CLASS "D" IN ACCORDANCE WITH AS3996.
5. ALL GRATES AND LIDS SHALL SIT FLAT WITH ITS SURROUND AND NOT BE LOOSE OR MOVE UNDER WHEEL Project No. Discipline Status
LOADS. 20210121 CIVIL PRELIMINARY
6. ALL STORMWATER STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE WITH LOCAL AUTHORITY GUIDELINES Designed By Drawn By Scale
(at
AND SPECIFICATIONS. WHERE STRUCTURES EXCEED MAXIMUM DEPTH AS IDENTIFIED WITHIN STANDARD B.PARRY J.CARR 1:100 A1)
DRAWINGS THE CONTRACTOR WILL ENSURE AN ADEQUATE STRUCTURAL DESIGN IS UNDERTAKEN FOR THE