Council archive · source document
06/0718 - MCU - Commercial Business Type 2 Medical & Type 1 Office [As Published] · 132006.718
” 241 David Low Way, Peregian Beach j interrupt the skyline; “Column 1 ~ Specific Outcomes C) is integrated with the natural site characteristics including vegetation; and Q) for Multiple housing, takes the form of small separate buildings. an Solutions (if Code Assessable). level design that step down. the slope or have suspended floor construction; AND $14.3 Cut or fill is less than 1.5m in depth; AND $14.4 The distance between the ground and the lowest part of the floor of the building does not exceed 3m to avoid large under- building areas; AND $14.5 Buildings present no more than— Q) if in the Visitor Mixed Use Zone — 3 storeys at any one point when viewed from the street; or b) if in any other Zone - 2 storeys at any one point when viewed from the street. ‘Column 2-Probable | Me tay uaa ee Entrance statement O15 A significant entrance statement is established at the southern entrance to Peregian Beach via the David Low Way to enhance and emphasises the sense of arrival to the coastal area of Noosa Shire from the south, No solution provided. The subject site is located north of Peregian Beach and therefore this Specific Outcome does not apply. 7.11 Environment, Conservation and Recreation Environment and cultural heritage values O16 There are no significant adverse effects on biodiversity, natural vegetation, native fauna habitat, landscape quality, water quality or cultural heritage values, including those related to— a) changes to natural drainage; b) changes to natural coastal processes: No solution provided Advisory note PSP24 - Effluent Disposal details requirements for the design and siting of effluent disposal systems where located outside a sewerage service area. Compliance with PSP24 will be considered as part of Council's The proposal does not have any significant effects on the biodiversity, native vegetation, native fauna, landscape quality, water quality or cultural heritage values in the locality. nh ken I ates IND AbSoE March 2006 Material Change of Use - Medical, Office and Ancillary Dwelling Unit Page 16 of 45
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - MCU - Commercial Business Type 2 Medical & Type 1 Office [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.