Mechanical plant ‘and
Outcomes
equipment and storage
areas
O04 Mechanical plant and
equipment (including air
conditioning equipment)
and storage areas are
designed and located
to—
a) avoid adverse visual
impacts when viewed
from the street and
adjoining properties; and
b) visually integrate with
the building design.
“Column 2- Probable —
Solutions
(Ure wate ticle) (9)
$4.1 Mechanical plant and
equipment are—
a) located more than 2m
from any property
boundary;
b) where located at
ground level, screened by
fencing 1.5m in height or
dense
vegetation of at least 1.5m
in width incorporating
grouped trees and shrubs
with maximum separation
distance of Im measured
from the centre of the tree
or scrub; and
c) are visually integrated
into the line and plane of
the building and roof
design
and do not project
beyond the height or
width of the building when
viewed from the street
and adjoining properties;
AND
$4.2 For industrial business
and Retail business Type 3,
materials stored outside of
a building do not exceed
4m in height or half the
height of the on-site
buildings whichever is the
greater.
Ab
ken hicks
pap eaeottaTrs
Pore k tila
All Mechanical plant and
equipment will be visually
integrated with the building
and located to avoid adverse
visual impacts when viewed
from the street and adjoining
properties.
Safety and security
O5 All property boundaries
are clearly identifiable
with public and private
spaces clearly defined.
O6 All premises and
access routes are clearly
identifiable to all persons,
particularly emergency
services personnel.
$5.1 Boundaries are
identified by such means
as -
a) fencing: or
b) changes in surface
materials or levels;
or
c) landscape treatments.
$6.1 All premises are
identified by the provision
of the street number in a
prominent location,
preferably near the site
O5 Boundaries are identified
though fencing.
O06 The premises will be clearly
identified with the street
number in a prominent
location.
March 2006
Material Change of Use - Medical, Office and Ancillary Dwelling Unit
Page 25 of 45
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - MCU - Commercial Business Type 2 Medical & Type 1 Office [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.