Council archive · source document
Item 7 Appendix A - Architectural Plans-1.0 · MCU22/0094
Plans and drawings: the text below has words only, no drawings.
Very large file (15.1 MB): may take a few minutes to open.
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
Aluminium frame 10.0° 10,370
Easement Boundary
Boundary
Boundary
7.5°
CLD-2 CLD-3
7.5°
CLD-2
3,000
2,400
FEN-1 FEN-4 FEN-3 FEN-3
1 North Elevation (Side Playscape)
- Scale 1:150
Boundary
Aluminium frame 10,370
Boundary
RT-1
CLD-2 CLD-3 CLD-2 CLD-3
3,000
2,400
FEN-1
CLD-1
2 East Elevation (Rear Playscape)
- Scale 1:150
ELEVATION &
SECTION LEGEND
CLD-1 CLD-2 CLD-3 CLD-4 RN-1 RT-1
RT-1 Roof type 1
BC Barge Capping
CLD-01 Cladding type 1
CLD-02 Cladding type 2
CLD-03 Cladding type 3 CLADDING CLADDING CLADDING CLADDING RENDER METAL ROOF SHEET
Aluminium Timber Look James Hardie Axon Vertical Linea Weatherboard James Hardie Axon Vertical Rendered Masonry in Colorbond Roof Sheet in Shale
RN-1 Render type 1 Vertical Cladding or similar Paint Colour: White or similar Timeless Grey Grey
LOU Louvre Knot Wood or Similar F.C Cladding 400mm F.C Cladding 135mm
RB Roof Beam Paint Colour: Dulux Teahouse Paint Colour: Dulux Teahouse
RC Ridge Capping
TOW Top Of Wall
WH Window Hood
FEN-1 Non Combustible Fence
Revision Project Architect Stage Project No.
Elevations (Sheet 02)
H Preliminary Issue 5/17/2022 Sanctuary Noosa Childcare Centre SC Development Approval 1187-05
I Preliminary Issue 5/17/2022 Lot 4 Noosa
J
K
Preliminary Issue
Preliminary Issue
5/18/2022
5/18/2022
Client
Stockwell Development Group Pty Ltd
Drawn
BL. HZ
Status
Not For Construction (#Notes)
Scale
1:150 at A3
A-DA-09.02 K
(07) 3251 6900 [email protected] Elevation Architecture Pty Ltd ACN 606 170 807 © Copyright reserved this document is and shall remain the property of Elevation Architecture. Unauthorised use of this document in any form whatsoever is prohibited. All information to be printed in colour. Figured dimensions take precedence over scale dimensions. Contractors must verify all dimensions on site before commencing any work or making shop drawings. P:\Data 1\1187-05 Sanctuary Noosa Childcare Centre\5.2 Development Application\5.2.1 ArchiCAD\1187-05 Master DA 24.pln
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Item 7 Appendix A - Architectural Plans-1.0.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.