Original source · versioned page text
19630-STRUCTURAL Drawings 15.06.21
Attached to the e-mail Operational Works Application OPW21/0189 - DA Form 1 Application Driveway crossovers & Stormwater Discharge connection 13-15 Hilton Esplanade Tewantin.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
PROPOSED NEW RESIDENCE
for P & R TAYLOR
13-15 HILTON ESPLANADE, TEWANTIN
DRG NO REVISION DRAWING TITLE
19630-S01 D COVER SHEET AND DRAWING INDEX
19630-S02 D GENERAL NOTES SHEET
19630-S03 D FOOTING PLAN AND DETAILS
19630-S04 D GROUND FLOOR PLAN AND DETAILS
19630-S05 D GROUND FLOOR DETAILS
SITE
19630-S06 D POOL DETAILS
19630-S07 D UPPER FLOOR/LOWER ROOF PLAN AND DETAILS
19630-S08 D UPPER FLOOR REINFORCEMENT PLANS
19630-S09 D UPPER FLOOR/LOWER ROOF DETAILS
19630-S10 D MAIN ROOF PLAN AND DETAILS
19630-S11 D ROOF DETAILS SHEET 1
19630-S12 D ROOF DETAILS SHEET 2
SERVICE LOCATIONS
SITE LOCATION PLAN It is the responsibility of the Foreman to
NOT TO SCALE BEFORE YOU DIG
contact the relevant service authorities
to ascertain the exact location of
services prior to construction.
Personal Protective
ENERGY SERVICE PROVIDERS Equipment
AGL HEAD
ERGON. EYES
ENERGY
energex EARS
origin BODY
NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM HANDS
PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED
Manual of Uniform Traffic Control Devices TELECOMMUNICATIONS PRIOR TO START OF CONSTRUCTION. PHONE DBYD
SERVICE LOCATIONS ON 1100 FOR DETAILS. FEET
SERVICE PROVIDERS
AUSTRALIA
' yes' Telstra visionstream
NOTE: ALL SIGNS & LINE MARKING TO BE IN
WARNING: OPTIC FIBRE OPTUS
EXTREME CARE TO BE TAKEN WHILE EXCAVATING IN THE NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM
ACCORDANCE WITH THE MANUAL OF PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED
VICINITY OF OPTIC FIBRE CABLES. LOCATIONS ARE TO
UNIFORM TRAFFIC CONTROL DEVICES. BE CONFIRMED PRIOR TO START OF CONSTRUCTION. PRIOR TO START OF CONSTRUCTION. PHONE DBYD
SERVICE LOCATIONS ON 1100 FOR DETAILS.
NOTE :
REFER TO ARCHITECTS DRAWINGS FOR
ALL SET OUT DIMENSIONS AND LEVELS.
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to A VENESS H GRAY
copyright in accordance with the P & R TAYLOR Designed Verified
PROPOSED NEW RESIDENCE COVER SHEET AS SHOWN A1
agreement between Tod
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
S PRYSTUPA H GRAY 13-15 HILTON ESPLANADE TEWANTIN AND DRAWING INDEX Drawing Number
D 15.06.21 REVISED TO SUIT ARCH CHANGES AV
used for this specific project.
C 10.03.21 REVISED TO SUIT ARCH CHANGES AV
Approved
S PRYSTUPA
RPEQ No
1137
RDP 19630-S01
This drawing shall not be used
Noosa: 07 5449 9600 LOCAL AUTHORITY NOOSA
B 4.03.21 ISSUED FOR TENDER AV Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
Signed Date MCU APPROVAL HORIZ DATUM 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 11.02.21 PRELIMINARY ISSUE AV
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
15.06.21
ROL APPROVAL
OPW APPROVAL
VERT DATUM
RL MEASUREMENT BAR - INCREMENTS IN mm
1 of 12 D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.