Skip to the record
Mmm.. taste the original NoosaWatch™

Council archive · source document

Minor Change Report 132001 210127 4 · 132001.210127.4

of 14

Text shows just the words. Original shows the document exactly as it was published.

               Existing Conditions 57 & 58
                      57.     A minimum of 44 car parking spaces must be provided and marked on the site and
                              made available and accessible at all times while the use is open for business. The
                              works must be generally in accordance with Proposed Overall Ground Floor Plan
                              (PD_A_003.1 E) dated 23 March 2023.
                      58.     Stormwater runoff from the development must be connected to a lawful point of
                              discharge without causing scour or damage to the subject site or any adjoining
                              properties. The works must be undertaken in accordance with an Operational Works
                              approval and be generally in accordance with STP Consultants’ Stormwater Layout
                              Plan (SKC01) dated 21 March 2023 and (SCK02) dated 20 March 2023. The works
                              must include, but not be limited to:
                              a.       All Causeways (both temporary and permanent) must be constructed to comply
                                       with all relevant sections of Queensland Urban Drainage Manual (QUDM);
                              b.       All Causeways (both temporary and permanent) must be constructed to comply
                                       with Section 10.3.5 of Sunshine Coast Council’s Open Space Landscape
                                       Infrastructure Manual 2022 (Type 5 Fire Access Trail); and
                              c.       Works must not adversely affect the existing water quality treatment capabilities
                                       of the development as to result in pollutants exiting the site.
               Applicant’s Request
               The applicant has not requested to amend Conditions 57 & 58.
               Assessment of Request
               Council’s Senior Development Engineer has reviewed the application material and provided an
               additional recommendation that conditions 57 and 58 are amended to the reflect that latest
               development layout and stormwater treatment devices (i.e., the additional infiltration trench). The
               amendments are considered necessary to ensure the development approval references the latest
               approved and referenced documents.



               Existing Conditions 65 & 69
                      65.     The development site must be landscaped. The works must be undertaken in
                              accordance with an Operational Works approval and the Noosa Plan for that specific
                              area and must include in particular:
                              a.       the works shown on the approved Landscape Concept plans shown in the
                                       Approved Plans
                              b.       Vegetation clearing within the site is to be offset through the rehabilitation of the
                                       area of vegetation adjacent to Cooyar Street. The area is to incorporate
                                       revegetation works that offset all native vegetation removal that is proposed on
                                       the site.
                              c.       control of all weeds species listed in the following standards and legislation:
                                       i.    declared plants under the Land Protection (Biodiversity Act 2014 and sub-
                                             ordinate Regulation 2016).
                                       ii.   Noosa Local Government Area Pest Management Plan 2015-2019.
                      69.     The existing Allocasurina littoralis in the south-eastern portion of the subject site must
                              be retained, except where required to be removed to accommodate the approved
                              building, in accordance with the recommendations of an Arborist Report (or part
                              thereof) prepared by a qualified person* and endorsed through an Operational Works
                              approval.
                              *(Refer to Advisory Note)

                                                                                                             Page 9 of 14

Document Set ID: 23161231
Version: 6, Version Date: 14/11/2024

Used in these records

About this file

File size
6.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Report 132001 210127 4.pdf · 6.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.