Original source · versioned page text
6 Martin St Peregian - DA - REV E- 04.05.23
Very large file (10.4 MB): the original may take a few minutes to open or download. The page text below is quick to read.
2/6 MARTIN STREET, PEREGIAN BEACH, QLD. USE FIGURED DIMENSIONS. DO NOT SCALE FROM THE DRAWINGS. CONFIRM ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION OR FABRICATION. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ENSURE COMPLIANCE WITH ALL RELEVANT PROPOSED ALTERATIONS & ADDITIONS - DA ISSUE CODES AND REGULATIONS IS MAINTAINED AT ALL TIMES. DATE ISSUE / AMENDMENT 4/05/2023 2:50:35 PM 09.11.2021 A DD ISSUE 20.01.2022 B DA ISSUE 06.09.2022 C DA REV 13.02.2023 D DA REV DRAWING LIST - DESIGN DEVELOPMENT 04.05.2023 E DA ISSUE E SHEET # SHEET NAME CURRENT REV. DATE DESCRIPTION DD-01 COVER SHEET E 04.05.2023 DA ISSUE E DD-02 PROPOSED SITE & ROOF PLAN E 04.05.2023 DA ISSUE E DD-03 LANDSCAPING & AREAS PLAN E 04.05.2023 DA ISSUE E DD-04 PLOT RATIO PLAN E 04.05.2023 DA ISSUE E DD-05 UNIT 2 PROPOSED GROUND FLOOR PLAN E 04.05.2023 DA ISSUE E DD-06 UNIT 2 PROPOSED FIRST FLOOR E 04.05.2023 DA ISSUE E DD-07 UNITS 1 & 2 EXISTING + DEMOLITION - GROUND FLOOR E 04.05.2023 DA ISSUE E DD-08 UNITS 1 & 2 EXISTING + DEMOLITION - FIRST FLOOR E 04.05.2023 DA ISSUE E DD-09 UNITS 1 & 2 EXISTING + DEMOLITION + PROPOSED - GROUND FLOOR E 04.05.2023 DA ISSUE E DD-10 UNITS 1 & 2 EXISTING + DEMO + PROPOSED - FIRST FLOOR PLAN E 04.05.2023 DA ISSUE E DD-11 UNIT 1 EXISTING + DEMOLITION + PROPOSED E 04.05.2023 DA ISSUE E DD-12 3D ELEVATIONS 01 E 04.05.2023 DA ISSUE E DD-13 3D ELEVATIONS 02 E 04.05.2023 DA ISSUE E DD-15 ELEVATIONS 01 E 04.05.2023 DA ISSUE E DD-16 ELEVATIONS 02 E 04.05.2023 DA ISSUE E DD-17 ELEVATIONS 03 E 04.05.2023 DA ISSUE E DD-20 SITE 3D VIEW E 04.05.2023 DA ISSUE E DCM BUILDING DESIGN MOB: 0422 722 719 OR 0412 277 163 EMAIL: info@dcmbuilding design.com.au QBCC: 1286569 & 1302906 PROJECT UNIT 2 / 6 MARTIN STREET PEREGIAN BEACH, QLD CLIENT TITLE COVER SHEET DATE 04.05.2023 SCALE DRAWN CHECKED SA DC PROJ No 21-068 DRAWING No ISSUE DD-01 E
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.
Full text of the other 17 pages
Page 2
Real Property
N
USE FIGURED DIMENSIONS. DO NOT SCALE
Description NEIGHBOURING HOUSE FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
Lot: 2 on SP215946 CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
Local Council: NOOSA
Area : 882m² PROPOSED ALTERATIONS & PROPOSED NEW DECK & ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ADDITIONS TO EXISTING UNIT 2 ROOF TO EXISTING UNIT 1
ALL TIMES.
Site Calculations DATE ISSUE / AMENDMENT
Site Cover m² Site Area Site Cover % 4/05/2023 2:50:41 PM
349 m² 882 m² 40% WATER 09.11.2021 A DD ISSUE
METER 20.01.2022 B DA ISSUE
06.09.2022 C DA REV
13.02.2023 D DA REV
9.0 4864 04.05.2023 E DA ISSUE E
WALL LEGEND 0
B WALL
1000
NEW BLOCK WALL RETAININ
G WALL
10 00
New Stud Wall (as dimensioned) FENCE 1.8h 13491
8.50
SB TO BT
Internal - 10mm Plasterboard - Paint Finish 950 0"
External - FC Sheet as noted on elevations
PROPOSED 1800h SLIDING GATE
Insulation to external walls to NCC requirements RETAININ TIMBER
G WALL FENCE
14045
1740 56"
Existing Wall - Retained
Varying construction types NEW PERGOLA
5100
5000
OVER GARAGE
4000
PROPOSED NEW DRIVEWAY
16759
& DROSSOVER IN
Existing Wall / Column - Demolished
Varying construction types
ACCORDANCE WITH NOOSA
ROOF DECK COURTYARD
TOWN PLAN GUIDELINES
10.00°
22128 4x DOWPIPES
9.
Floor Areas
00
3550 0"
PROPOSED
940
UNIT 1 GATEHOUSE
GROUND FLOOR UP
EXTERNAL
SEWER
SEWER
Alfresco 25.06 m² 7.50° 10.00° 19748
R.C. AWNING
Porch 12.00 m²
NEW BLOCK WALL FENCE 1.8h w/ BREEZEBLOCK
4500 1750 0"
INTERNAL
7.50°
SB to OMP
Garage 53.72 m²
Living 92.87 m²
YARD
GARDEN
183.65 m²
8.00 COLORBOND ROOF SHEET, EXISTING COLORBOND ROOF
FIRST FLOOR 1000 FASCIA & GUTTERS SHEET, FASCIA & GUTTERS
EXTERNAL
Deck 8.17 m²
1200
POOL FENCE 13325 2650 04' 15" 8.50
INTERNAL 10.00°
Living 96.44 m²
104.61 m² YARD
288.26 m² 8 .00
54
85 L1) NEW POOL OPEN PERGOLA DP
64
P(
27
1 .8 % T
O M
50
10.00°
31
m R AN
UNIT 2 TO
TIMBER FENCE
BA SP
DCM BUILDING DESIGN
8
SB
0 0
TTE A R
"
GROUND FLOOR MOB: 0422 722 719 OR 0412 277 163
N
FEN ENCY
EMAIL: info@dcmbuilding design.com.au
CE
EXTERNAL
w/
Alfresco 29.83 m²
NEW QBCC: 1286569 & 1302906
1.8h
EXISTI
NG DR IVEW PATH
AY (D
EMOL
Porch 9.63 m²
CE
OMP
ISHED
) EXISTING DRIVEWAY
LL FEN
NEW GARD (DEMOLISHED) PROJECT
EN
1000
Verandah 5.20 m² BLOC
K WA GA T E
UNIT 2 / 6 MARTIN STREET
B TO
LL FEN
5000
K WA
INTERNAL CE 1.8
h w/
BREE
ING S
8.00
EXISTING DRIVEWAY ALTERED
BLOC
ZE BLOC 8.00
Garage 45.21 m² WATE K
5947
R 1476
NEW
Living 119.71 m² 4
PEREGIAN BEACH, QLD
EXIST
9928
209.57 m² FH
1750 0'
FIRST FLOOR 8.00
EXTERNAL 1440
5
PROPO 101 0 CLIENT
Garage Roof Deck & Balcony 43.53 m² S 0"
MAILB ED
INTERNAL OX
Living 100.73 m² TITLE
PROPOSED SITE & ROOF PLAN
SEWER
144.26 m²
353.83 m²
Total 642.10 m²
DATE
04.05.2023
SCALE
As indicated
DRAWN CHECKED
SA DC
PROJ No
1 PROPOSED SITE & ROOF PLAN 21-068
0 2 4 6 8 10m
DRAWING No ISSUE
E
SCALE 1 : 200
DD-02
Page 3
USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
UNIT 1
PRIVATE OPEN SPACE
DATE ISSUE / AMENDMENT
126.4m² 4/05/2023 2:50:48 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
UP PRIVATE OPEN SPACE AREAS 06.09.2022
13.02.2023
C
D
DA REV
DA REV
04.05.2023 E DA ISSUE E
UNIT NAME AREA
1 SOFT LANDSCAPING 145.0m²
1 PRIVATE OPEN SPACE 126.4m²
UP
271.4m²
2 SOFT LANDSCAPING 158.6m²
2 PRIVATE OPEN SPACE 199.6m²
UNIT 2 359.2m²
PRIVATE OPEN SPACE OPEN PERGOLA
190.1m² SOFT LANDSCAPING TOTAL UNIT 1 & 2 = 303.6m²
SITE AREA = 882m²
SOFT LANDSCAPING SITE COVER = 34%
1 PRIVATE OPEN SPACE AREA PLAN
SCALE 1 : 250
UNIT 1
SOFT LANDSCAPING
145.0m²
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
UNIT 1 SOFT LANDSCAPING = 145.0m² QBCC: 1286569 & 1302906
UP
UNIT 1 HARD LANDSCAPING = 109.2m²
TOTAL = 254.2m² PROJECT
UNIT 2 / 6 MARTIN STREET
UNIT 2 SOFT LANDSCAPING = 158.6m²
UNIT 2 HARD LANDSCAPING INC. POOL = 151.6m²
PEREGIAN BEACH, QLD
TOTAL = 310.2m²
UP
CLIENT
UNIT 2
SOFT LANDSCAPING
OPEN PERGOLA TITLE
149.3m² LANDSCAPING & AREAS PLAN
UNIT 2
HARD LANDSCAPING
154.7m² DATE
UNIT 1 04.05.2023
SCALE
HARD LANDSCAPING As indicated
109.20m² DRAWN
SR
CHECKED
DC
PROJ No
21-068
2 SOFT LANDSCAPING PLAN DRAWING No ISSUE
SCALE 1 : 250 DD-03 E
Page 4
USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
GROSS FLOOR AREAS
DATE ISSUE / AMENDMENT
LEVEL AREA 4/05/2023 2:50:54 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
UP
GROUND FLOOR 201.1m2 06.09.2022 C DA REV
13.02.2023 D DA REV
FIRST FLOOR 160.2m2 04.05.2023 E DA ISSUE E
361.3m2
SITE AREA = 882m2
PLOT RATIO = 361.3/882
UP = 0.409
OPEN PERGOLA
Site Calculations
Site Cover m² Site Area Site Cover %
349 m² 882 m² 40%
FIRST FLOOR - GROSS FLOOR AREA
AS DEFINED BY NOOSA SHIRE COUNCIL TABLE SC1.2.1
1 PROPOSED FIRST FLOOR - GROSS FLOOR AREA
SCALE 1 : 250
GROUND FLOOR - GROSS FLOOR AREA WALL BE
LOW
AS DEFINED BY NOOSA SHIRE COUNCIL TABLE SC1.2.1
WALL BELOW
WALL BELOW
GARAGE BELOW
430
OH
900
OPEN PERGOLA
WALL BELOW DCM BUILDING DESIGN
800
OH
OH
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
WALL BELOW
UP QBCC: 1286569 & 1302906
WALL BELOW
PROJECT
WALL BELOW UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
900
OH
UP
CLIENT
OPEN PERGOLA
TITLE
OPEN PERGOLA
PLOT RATIO PLAN
DATE
04.05.2023
SCALE
1 : 250
DRAWN CHECKED
SA DC
PROJ No
21-068
DRAWING No ISSUE
2 PROPOSED GROUND FLOOR - GROSS FLOOR AREA
SCALE 1 : 250
3 SITE COVER PLAN
SCALE 1 : 250
DD-04 E
Page 5
RETAININ
G WALL
BIN STORE
190 6620 190
N USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
10 00
CONSTRUCTION OR FABRICATION. IT REMAINS
RETAININ THE CONTRACTORS RESPONSIBILITY TO
G WALL
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
WORKBENCH
DRIVEWAY DATE ISSUE / AMENDMENT
4000
4/05/2023 2:50:58 PM
GARAGE
5000
5000
EXP. AGG.
09.11.2021 A DD ISSUE
6.6 x 5.7 20.01.2022 B DA ISSUE
CONCRETE 06.09.2022 C DA REV
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
COURTYARD
CD
LDRY
WM
190
PLANTER BED
190
190
2995
R.C. AWNING OVER
2060
2060
GATE GATE
EXP. AGG.
0618AW ENTRY 2436SGD
190
190
190
VO
ID UP
OV
E R
STORE
2500
0924 LV/FG/LG OFFICE BATH UP
3780
3590
3.5 x 3.0
LIVING
820
190 1000 90
4.5 x 4.0
MEDIA CABINET
B
820
DD-18
R.C. AWNING OVER
70 550
STORE
8250
PTRY
FRIDGE
UP
KITCHEN
4.6 x 3.1
4660
06/27FG
4470
4040
BUILDING OVER
DINING
4.7 x 3.5
VO
ID
OV
E
DCM BUILDING DESIGN
VINYL R
MOB: 0422 722 719 OR 0412 277 163
GATE EMAIL: info@dcmbuilding design.com.au
190
190
190
205
QBCC: 1286569 & 1302906
GLASS POOL FENCE 1509LV 2445SGD
GATE
CONC POOL SURROUND PROJECT
UNIT 2 / 6 MARTIN STREET
R.C. AWNING OVER
OPEN PERGOLA PEREGIAN BEACH, QLD
EXPOSED FRAMING OVER
GLASS POOL FENCE
ALFRESCO
5.5 x 5.2
CLIENT
POOL
5180
TIMBER DECK TITLE
UNIT 2 PROPOSED GROUND FLOOR
TIMBER BENCH SEAT w/ GLASS POOL FENCE OVER PLAN
POOL EQUIP.
DATE
250 190 90 600
WALL LEGEND 04.05.2023
3040 90 2270 1325 5525 190 SCALE
New Stud Wall (as dimensioned) As indicated
190 12940 190 Internal - 10mm Plasterboard - Paint Finish
DRAWN CHECKED
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
SA DC
3500 PROJ No
Existing Wall - Retained
21-068
1 PROPOSED GROUND FLOOR Varying construction types DRAWING No ISSUE
SCALE
0
1 : 100
1 2 3 4 5m
1
DD-19
A
DD-18 Existing Wall / Column - Demolished
DD-05 E
Varying construction types
Page 6
USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
N ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:02 PM
09.11.2021 A DD ISSUE
GARAGE ROOF DECK 20.01.2022 B DA ISSUE
06.09.2022 C DA REV
6.3 x 4.4
5920
13.02.2023 D DA REV
PERGOLA OVER COURTYARD BELOW 04.05.2023 E DA ISSUE E
SU
S
PE
ND
ED
CO
NC
RE
TE
SL
6285
AB
4x DOWPIPES
BALCONY ROOF LINE OVER
R.C. AWNING
OPEN BELOW
GATEHOUSE 2160
90 900
1506AW OBS 2431SGD 820
2145FG
90 790 90
90
90
STEP
UP
SUSPENDED CONCRETE SLAB
2/820 C/S
BED 1
2590
4360
WIR VO
ID
4.2 x 3.3
B
DD-18
90 800 90
8250
8340
820 C/S
90
ROBE
LINEN
0636 RAKED (HIGH LEVEL)
ENSUITE RA
BED 2
VO
KE
BATH DC
ID
TILES EI L
I NG
3.3 x 3.3 TILES
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
1000 90
QBCC: 1286569 & 1302906
0921 LV/FG/LV 0921 LV/FG/LV 0921 LV/FG/LV
R.C. AWNING PROJECT
ROOF LINE OVER
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
OPEN PERGOLA
CLIENT
TITLE
UNIT 2 PROPOSED FIRST FLOOR
90 2100 90 5550 90 WALL LEGEND
DATE
1500 90 3485 90 1000 5815 New Stud Wall (as dimensioned) 04.05.2023
Internal - 10mm Plasterboard - Paint Finish SCALE
90 7740 90 3960 190 External - FC Sheet as noted on elevations As indicated
Insulation to external walls to NCC requirements
DRAWN CHECKED
SA DC
Existing Wall - Retained
PROJ No
Varying construction types
21-068
1 PROPOSED FIRST FLOOR DRAWING No ISSUE
SCALE 1 : 100
DD-19
1
DD-18
A Existing Wall / Column - Demolished
Varying construction types DD-06 E
0 1 2 3 4 5m
Page 7
N USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:03 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
06.09.2022 C DA REV
WALL LEGEND
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
New Stud Wall (as dimensioned)
Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
Existing Wall - Retained
Varying construction types
Existing Wall / Column - Demolished
Varying construction types
UP
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
QBCC: 1286569 & 1302906
PROJECT
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
CLIENT
TITLE
UNITS 1 & 2 EXISTING + DEMOLITION -
GROUND FLOOR
DATE
04.05.2023
SCALE
As indicated
DRAWN CHECKED
SA DC
PROJ No
1 EXISTING + DEMOLITION - GROUND FLOOR 21-068
DRAWING No ISSUE
E
SCALE 1 : 100
0 1 2 3 4 5m DD-07
Page 8
N USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:04 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
06.09.2022 C DA REV
WALL LEGEND
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
New Stud Wall (as dimensioned)
Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
Existing Wall - Retained
Varying construction types
Existing Wall / Column - Demolished
Varying construction types
UP
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
QBCC: 1286569 & 1302906
PROJECT
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
CLIENT
TITLE
UNITS 1 & 2 EXISTING + DEMOLITION -
FIRST FLOOR
DATE
04.05.2023
SCALE
As indicated
DRAWN CHECKED
SA DC
PROJ No
EXISTING + DEMOLITION FIRST FLOOR 21-068
1 DRAWING No ISSUE
SCALE 1 : 100
0 1 2 3 4 5m DD-08 E
Page 9
N USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:07 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
06.09.2022 C DA REV
WALL LEGEND
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
New Stud Wall (as dimensioned)
Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
Existing Wall - Retained
Varying construction types
Existing Wall / Column - Demolished
Varying construction types
UP
UP
UP
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
QBCC: 1286569 & 1302906
PROJECT
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
CLIENT
TITLE
UNITS 1 & 2 EXISTING + DEMOLITION
+ PROPOSED - GROUND FLOOR
DATE
04.05.2023
SCALE
As indicated
DRAWN CHECKED
SA DC
PROJ No
21-068
DRAWING No ISSUE
1 EXISTING + DEMOLITION + PROPOSED GROUND FLOOR
SCALE 1 : 100 0 1 2 3 4 5m
DD-09 E
Page 10
N USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:09 PM
09.11.2021 A DD ISSUE
20.01.2022 B DA ISSUE
06.09.2022 C DA REV
WALL LEGEND
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
New Stud Wall (as dimensioned)
Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
Existing Wall - Retained
Varying construction types
Existing Wall / Column - Demolished
Varying construction types
UP
UP
UP
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
QBCC: 1286569 & 1302906
PROJECT
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
CLIENT
TITLE
UNITS 1 & 2 EXISTING + DEMO +
PROPOSED - FIRST FLOOR PLAN
DATE
04.05.2023
SCALE
As indicated
DRAWN CHECKED
SA DC
PROJ No
21-068
1 EXISTING + DEMOLITION + PROPOSED - FIRST FLOOR DRAWING No ISSUE
SCALE 1 : 100 0 1 2 3 4 5m
DD-10 E
Page 11
1
UP UP
DN
UP
1
2
3
4
5
6
STIARS
7
3750
8
9
10
11
12
13
14
DP
70
15
DP
16
P P P
2418SGD
DECK OVER
ROOF OVER
2305
PORCH DECK
2620
DECK
P P
245
STAIRS
1000
2650 470
DECK
3120
1 U1 EXISTING + DEMOLITION + PROPOSED GROUND FLOOR 2 U1 EXISTING + DEMOLITION + PROPOSED - FIRST FLOOR
SCALE 1 : 100 SCALE 1 : 100
UNIT 1 EXISTING +
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021
20.01.2022
A
B
DD ISSUE
DA ISSUE
UNIT 2 / 6 MARTIN STREET DEMOLITION + PROPOSED
MOB: 0422 722 719 or
06.09.2022 C DA REV DATE
0412 277 163
13.02.2023 D DA REV 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
PEREGIAN BEACH, QLD SCALE
1 : 100
21-068
PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL Author Checker
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
CLIENT
DD-11 E
ALL TIMES.
4/05/2023 2:51:10 PM
Page 12
PERGOLA
PRIVACY SCREEN
LINE OF BOUNDARY FENCE
SHOWN DASHED
NEIGHBOURING HOUSE
COLORBOND SHEET ROOF,
FASCIA & GUTTERS
PERGOLA OVER BLOCK WORK WALL, RENDERED
GARAGE ROOF DECK
NORTHERN PERSPECTIVE
GLASS BALUSTRADE
EXISTING UNIT BEHIND
VERTICAL GROOVE SHEET CLADDING, PAINTED
NEW RENDERED BLOCK WALLS
1800h BLOCK WORK FENCE
1800h TIMBER FENCE
OPEN PERGOLA
NEW RETAINING WALL
WESTERN PERSPECTIVE
BATTEN SCREENING TO GARAGE
DOOR, MATCHED SURROUNDING VERTICAL GROOVE
WALL BATTENS & BALUSTRADES SHEET CLADDING,
PAINTED
P.C ALUMINIUM FRAMED
WINDOWS & DOORS
R.C. AWNING
NEW RENDERED BLOCK WALLS
1800h BLOCK WORK FENCE
w/ BREEZEBLOCKS SHOWN
TRANSPARENT
DATE ISSUE / AMENDMENT SOUTHERN PERSPECTIVE PROJECT TITLE
3D ELEVATIONS 01
DCM BUILDING DESIGN & DRAFTING
09.11.2021
20.01.2022
A
B
DD ISSUE
DA ISSUE
UNIT 2 / 6 MARTIN STREET
MOB: 0422 722 719 or
06.09.2022 C DA REV DATE
0412 277 163
13.02.2023 D DA REV 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
PEREGIAN BEACH, QLD SCALE
21-068
PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
CLIENT
DD-12 E
ALL TIMES.
4/05/2023 2:51:20 PM
Page 13
NEIGHBOURING HOUSE
COLOURBOND SHEET
ROOF, FASCIA& GUTTERS
TIMBER BALUSTRADES,
PAINTED
NEW TIMBER FRAMED
FLOOR & POSTS
EASTERN PERSPECTIVE
3D ELEVATIONS 02
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021
20.01.2022
A
B
DD ISSUE
DA ISSUE
UNIT 2 / 6 MARTIN STREET
MOB: 0422 722 719 or
06.09.2022 C DA REV DATE
0412 277 163
13.02.2023 D DA REV 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
PEREGIAN BEACH, QLD SCALE
21-068
PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
CLIENT
DD-13 E
ALL TIMES.
4/05/2023 2:51:27 PM
Page 14
L1 CEILING
L1 JOINERY
2145FG
7655 BUILDING HEIGHT
2/820 C/S
2700
2400
OPEN PERGOLA
FIRST FLOOR
GF CEILING
GF JOINERY
820 C/S
2445SGD
2700
2400
1060
8300
GROUND FLOOR
1 UNIT 2 - EASTERN ELEVATION PRIVACY SCREEN
SCALE 1 : 100
L1 CEILING
L1 JOINERY
7655 BUILDING HEIGHT
2145FG
2700
2400
1000
FIRST FLOOR
GF CEILING
GF JOINERY EXISTING U2 CEILING
2070
EXISTING U2 JOINERY
2436SGD
2700
2400
2400
LINE OF RETAINING WALL
2100
NATURAL GROUND LINE AT
980
RETAINING WALL BOUNDARY SHOWN DASHED RETAINING WALL
8300
GROUND FLOOR
WALL SETBACK 1.0m
8300
GROUND FLOOR
2 UNIT 2 - NORTHERN ELEVATION
SCALE 1 : 100
0 1 2 3 4 5m
ELEVATIONS 01
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021 A DD ISSUE WALL LEGEND UNIT 2 / 6 MARTIN STREET
20.01.2022 B DA ISSUE MOB: 0422 722 719 or
06.09.2022 C DA REV New Stud Wall (as dimensioned) DATE
0412 277 163
13.02.2023 D DA REV Internal - 10mm Plasterboard - Paint Finish 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
External - FC Sheet as noted on elevations PEREGIAN BEACH, QLD SCALE
Insulation to external walls to NCC requirements
As indicated
21-068
Existing Wall - Retained PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL Varying construction types SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
Existing Wall / Column - Demolished
Varying construction types
CLIENT
DD-15 E
ALL TIMES.
4/05/2023 2:51:33 PM
Page 15
L1 CEILING
L1 JOINERY
0921 LV/FG/LV 0921 LV/FG/LV 0921 LV/FG/LV
2700
2400
OPEN PERGOLA
FIRST FLOOR
GF CEILING
EXISTING U2 CEILING GF JOINERY
2409LV
EXISTING U2 JOINERY 1509LV 2409LV 2429FG
2445SGD
2700
2400
2400
2100
8300 8300
GROUND FLOOR GROUND FLOOR
1 UNIT 2 - SOUTHERN ELEVATION
SCALE 1 : 100
0636 RAKED (HIGH LEVEL)
L1 CEILING
L1 JOINERY
2700
2400
FIRST FLOOR
GF CEILING
EXISTING U2 CEILING GF JOINERY
0924 LV/FG/LG
EXISTING U2 JOINERY
2700
2400
2400
06/27FG
2100
8300 8300
GROUND FLOOR GROUND FLOOR
2 UNIT 2 - WESTERN ELEVATION
SCALE 1 : 100
ELEVATIONS 02
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021 A DD ISSUE WALL LEGEND UNIT 2 / 6 MARTIN STREET
20.01.2022 B DA ISSUE MOB: 0422 722 719 or
06.09.2022 C DA REV New Stud Wall (as dimensioned) DATE
0412 277 163
13.02.2023 D DA REV Internal - 10mm Plasterboard - Paint Finish 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
External - FC Sheet as noted on elevations PEREGIAN BEACH, QLD SCALE
Insulation to external walls to NCC requirements
As indicated
21-068
Existing Wall - Retained PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL Varying construction types SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
Existing Wall / Column - Demolished
Varying construction types
CLIENT
DD-16 E
ALL TIMES.
4/05/2023 2:51:38 PM
Page 16
L1 CEILING
L1 JOINERY
7655 BUILDING HEIGHT
2700
2400
RAISE EXISTING
OPEN PERGOLA
WALLS BY 300mm
GF CEILING
FIRST FLOOR
300
GF CEILING
GF JOINERY EXISTING U2 CEILING
EXISTING U2 JOINERY
2700
2400
2400
2100
8300
GROUND FLOOR
A UNIT 2 - BUILDING SECTION A
SCALE 1 : 100
L1 CEILING
L1 JOINERY
2700
2400
FIRST FLOOR
GF CEILING
GF JOINERY EXISTING U2 CEILING
EXISTING U2 JOINERY
2700
2400
2400
2100
8300 8300
GROUND FLOOR GROUND FLOOR
B UNIT 2 - BUILDING SECTION B
SCALE 1 : 100
0 1 2 3 4 5m
SECTIONS 01
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021 A DD ISSUE WALL LEGEND UNIT 2 / 6 MARTIN STREET
20.01.2022 B DA ISSUE MOB: 0422 722 719 or
06.09.2022 C DA REV New Stud Wall (as dimensioned) DATE
0412 277 163
13.02.2023 D DA REV Internal - 10mm Plasterboard - Paint Finish 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
External - FC Sheet as noted on elevations PEREGIAN BEACH, QLD SCALE
Insulation to external walls to NCC requirements
As indicated
21-068
Existing Wall - Retained PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL Varying construction types SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
Existing Wall / Column - Demolished
Varying construction types
CLIENT
DD-18 E
ALL TIMES.
4/05/2023 2:51:42 PM
Page 17
2600 MEAS. BOUNDARY
PAR. TO B'DARY
L1 JOINERY
GARAGE ROOF DECK BALCONY STUDY
2700
2400
OPEN PERGOLA RAISE EXISTING
WALLS BY 300mm
FIRST FLOOR
GF CEILING
300
GF JOINERY
2050
GARAGE ENTRY DINING KITCHEN EXISTING U2 CEILING
2700
2400
2400
2100
EXISTING U2 JOINERY
8300
GROUND FLOOR
1 UNIT 2 - BUILDING SECTION C
SCALE 1 : 100
0 1 2 3 4 5m
SECTIONS 02
DATE ISSUE / AMENDMENT PROJECT TITLE
DCM BUILDING DESIGN & DRAFTING
09.11.2021 A DD ISSUE WALL LEGEND UNIT 2 / 6 MARTIN STREET
20.01.2022 B DA ISSUE MOB: 0422 722 719 or
06.09.2022 C DA REV New Stud Wall (as dimensioned) DATE
0412 277 163
13.02.2023 D DA REV Internal - 10mm Plasterboard - Paint Finish 04.05.2023
04.05.2023 E DA ISSUE E
EMAIL: [email protected]
QBCC: 1286569 & 1302906
External - FC Sheet as noted on elevations PEREGIAN BEACH, QLD SCALE
Insulation to external walls to NCC requirements
As indicated
21-068
Existing Wall - Retained PROJ No
USE FIGURED DIMENSIONS. DO NOT SCALE DRAWN CHECKED
FROM THE DRAWINGS. CONFIRM ALL Varying construction types SA DC
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS DRAWING No ISSUE
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
Existing Wall / Column - Demolished
Varying construction types
CLIENT
DD-19 E
ALL TIMES.
4/05/2023 2:51:44 PM
Page 18
USE FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
DIMENSIONS ON SITE PRIOR TO
CONSTRUCTION OR FABRICATION. IT REMAINS
THE CONTRACTORS RESPONSIBILITY TO
ENSURE COMPLIANCE WITH ALL RELEVANT
CODES AND REGULATIONS IS MAINTAINED AT
ALL TIMES.
DATE ISSUE / AMENDMENT
4/05/2023 2:51:48 PM
09.11.2021 A DD ISSUE
NEIGHBOURING HOUSE 20.01.2022 B DA ISSUE
06.09.2022 C DA REV
13.02.2023 D DA REV
04.05.2023 E DA ISSUE E
DCM BUILDING DESIGN
MOB: 0422 722 719 OR 0412 277 163
EMAIL: info@dcmbuilding design.com.au
QBCC: 1286569 & 1302906
PROJECT
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
CLIENT
TITLE
SITE 3D VIEW
NEIGHBOURING HOUSE
SHOWN TRANSPERANT DATE
04.05.2023
SCALE
DRAWN CHECKED
SA DC
PROJ No
21-068
DRAWING No ISSUE
DD-20 E