Attachment 1 - Proposal Plans · 51995.1645.01
Attached to the e-mail Lodgement of Development Application - 51995.1645.01.
Plans and drawings: the text below has words only, no drawings.
1. 2 3 4 5 6
TENDER
NOT FOR CONSTRUCTION
GENERAL NOTES:
(these notes apply to all drawings)
A • These designs, drawings and specifications are copyright
and the property of Cayas + Ward and must not be used,
reproduced or copied wholly or in part without the
permission of Cayas + Ward.
• Do not scale - use figured dimensions in preference to
scaled dimensions.
• All dimensions must be checked on site prior to the
commencement of construction and/or manufacture of any
item.
DASH INDICATES ROOF BELOW • Where demolition work is included, allow to make good all
affected surfaces.
• Ensure that all conditions of the building certification are
B complied with.
• Where ambiguities or discrepancies exist, Cayas + Ward
shall be contacted for clarification, or it will be deemed that
EXISTING ROOF the more expensive option has been allowed.
• All work is to comply with all relevant sections of NCC
and/or Australian Standards.
• These drawings are to be read in conjunction with all other
ROOF OVERHEAD documentation, schedules & consultant documentation.
A100.05 • The contractor is to allow for all necessary floor preparation
works.
12
• Provide all warranties as per the manufacturers & suppliers
standard warranties.
• All materials, equipment, fixtures, fittings, etc. Shall be new
EXISTING ROOF BALCONY EXISTING ROOF first quality without exception. Supply, delivery, storage,
installation, etc. Is to be as per the manufacturers most
EXISTING LEVEL 1, NO NEW WORK recent written recommendations.
• Supply & install fire extinguishers to comply with Australian
Standards to the area of the proposed work.
• Termite protection is to be provided to comply with AS
3660.1-2000 and clarification to be provided on completion.
• The construction and fit out of commercial kitchens and
C bars are to comply with AS 4674-2004.
• Builder to inspect existing walls that are proposed to have
R
new finishes and ensure that a suitable substrate is present
or is provided to achieve the specified finish. Builder to
D
inspect existing walls that are proposed to conceal services
and ensure that an adequate cavity is present or provide
SA
furring channels.
BEDROOM EXISTING ROOF
O
LIVING ROOM
O
N
D
SUBJECT AREA OF PROPOSED
WORKS SHOWN SHADED
BATHROOM
NEW ENTRY AWNING BELOW TO KITCHEN
EXISTING ROOF BEDROOM EXISTING ROOF
GAMING. REFER TO ELEVATION
FALL
NEW WINDOW AWNING BELOW
E
STAIR
UP
EXISTING ROOF BELOW
RY
DA
N
OU
EB
SIT
20
0
EXISTING ROOF
F
EXISTING ROOF
G
SUBJECT AREA OF PROPOSED
WORKS SHOWN SHADED
EXISTING SIGNAGE PYLON TO REMAIN
FALL
NEW ENTRY AWNING
STRUCTURE EXISTING ROOF
D General Updates RH 16.05.25
C General updates DV 29.04.25
H B Consultant Issue RH 12.02.25
A Consultant Issue RH 24.01.25
issue revision initials date
Cayas
+ Ward
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
client ALH Group
project Noosa Reef Hotel
19 Noosa Dr, Noosa Heads
QLD 4567
drawing title Proposed Level 1 Floor Plan
ADJOINING BWS TENNANCY
drawn RH
date MAY 2025
scale 1 : 100@A1
project no. drawing number issue
Existing Level 1 - Floor Plan
1 1 : 100 2395 A100.03 D
OUT OF SCOPE
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 1 - Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.