                                                                                                       Including amendments to 3 July 2017
                  Specific Outcomes                                   Probable solutions




                                                                                           The Noosa Plan
Site cover & gross floor area & plot ratio
O7 The site cover, gross floor area and plot              No solution provided
ratio of buildings and other roofed structures—
a)     results in a building scale that is compatible
       with surrounding development;
b)     does not present an appearance of bulk to
       adjacent properties, roads or other areas in
       the vicinity of the site;
c)     maximises the retention of existing
       vegetation and allows for soft landscaping
       between buildings;
d)     allows for adequate area at ground level for
       outdoor recreation, entertainment, clothes
       drying and other site facilities; and
e)     facilitates onsite stormwater management
       and vehicular access.

O8 Site cover does not exceed—
a) for a class 1 or class 10a building within the
   Detached Housing Zone, —
    i    for a single storey building - 50%; or
    ii   for a building of 2 or more storeys -
         50% on the ground floor and 30% for
         the upper storey(s), or 40% for all
         storeys for a building of 2 or more
         storeys;
b) for other classes within the Detached House
   Zone - 40%; or
c) for the Semi-Attached Housing Zone–40%.

O9 For Multiple housing Type 2 buildings
have a maximum plot ratio of 0.45:1.

O10 For Multiple housing Type 3, Visitor
accommodation Type 4 and the
accommodation unit component of an
Entertainment and dining business Type 3—
the maximum gross floor area is equivalent to the
maximum allowable population in persons
multiplied by 40m2.

O11 For the Village Mix Zone, plot ratio does not
exceed 1.0:1.




                                                   8-37
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.