                   column 1                                                     column 2
               Specific Outcomes                                          Probable solutions
                                                                  features such as varying materials,
                                                                  finishes, horizontal and vertical




                                                                                                                           Including amendments to 3 July 2017
                                                                  articulation, break up building bulk and




                                                                                                               The Noosa Plan
                                                                  create interest and shadow lines.
                                                                  Awnings create interest and the roof
                                                                  profile aims to reduce building bulk by
                                                                  sloping to perimeter gutters).

                                                            Figure 11.2—Use of design features to
                                                            break up building bulk




O35 Buildings give the physical appearance of               S35.1 No solution provided
being one Detached house.

O36 Buildings and structures are designed to                S36.1 No solution provided
address any waterfront aspect and to contribute
positively to the waterfront character.

Garages and carports
O37 Garages and carports are designed and                   S37.1 Garages and carports—
sited to visually integrate with the building and           a)    have a front boundary setback of at
avoid dominating the street.                                      least 6m; and
                                                            b)    adopt a roof form and building style
                                                                  similar to that of the building; and
                                                            c)    present a minimum width to the
                                                                  streetscape (the total width of garage
                                                                  doors is no more than 6m or 50% of the
                                                                  frontage width, whichever is the lesser,
                                                                  where the structure faces the street); or
                                                            d)    that are visible from, but do not face the
                                                                  street, include windows or other
                                                                  articulation and have a 6m landscaped
                                                                  buffer between the structure and the
                                                                  road frontage.
Setbacks to watercourses of Noosa Waters
Estate
O38 Buildings works, filling or excavation works            S38.1 For lots adjacent to the watercourses of
and improvements for lots adjacent to the                   Noosa Waters Estate, building works, filling or
watercourses of the Noosa Waters Estate are                 excavation works and improvements are
appropriately designed and sited to ensure that—            undertaken no closer than 4.5m from the
a)    the flood storage capacity of the                     centreline of the concrete revetment wall.
      watercourse is not affected;
b)    no additional load is placed on the
      revetment walls;
c)    the membrane adjoining the revetment wall



                                                    11-49
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.