Table 13.10 Flood Hazard areas
                       column 1                                                    column 2




                                                                                                                                    Including amendments to 3 July 2017
                   Specific Outcomes                                           Probable solutions




                                                                                                                        The Noosa Plan
13.38      Flood Plain Protection, Immunity and Safety
Hazardous materials                                        S14.1 Materials manufactured or stored on-site
O14 Development avoids the release of                      are not hazardous or noxious, or comprise
hazardous materials into floodwaters and the               materials that may cause a detrimental effect on
environment.                                               the environment if discharged in a flood event; or

                                                           S14.2 Structures used for the manufacture or
                                                           storage of hazardous materials are—
                                                           a) located above the defined flood level; or
                                                           b) designed to prevent the intrusion of
                                                                floodwaters45.

Essential network infrastructure
O15 Essential network infrastructure (e.g.                 S15.1 Components of the essential network
electricity, water supply, sewerage and                    infrastructure that are likely to fail or may result in
telecommunications) maintains effective                    contamination when affected by flood water—
function during and immediately after flood                a) comply with Table 13.12; or
events.                                                    b) are designed and constructed to exclude
                                                                water inundation or infiltration and resist
                                                                hydrostatic and hydrodynamic forces as a
                                                                result of inundation.
O16 Community Uses and Infrastructure Uses                 S16.1 Community Uses and Infrastructure
are able to function effectively during and                Uses are sited and constructed to ensure that
immediately after flood events.                            floor levels comply with flood immunity
                                                           requirements specified in Table 13.12;

                                                           OR

                                                           S16.2 Essential community infrastructure which
                                                           is located below the specified flood immunity
                                                           requirements—
                                                           a)      is designed and constructed to function
                                                                   effectively during and immediately after the
                                                                   recommended flood level flood event; and

                                                           b)      has an emergency rescue area above the
                                                                   probable maximum flood if it is for
                                                                   emergency services (including emergency
                                                                   shelters, police facilities, hospitals and
                                                                   associated facilities).




45
  Refer to the Work Health and Safety Act 2011 and associated Regulation and Guidelines, the Environmental Protection
Act 1994 and the relevant building assessment provisions under the Building Act 1975 for requirements related to the
manufacture and storage of hazardous substances.


                                                       13-47
                                   Natural Hazards and Natural Resources Overlays
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.