                                                  Table 14-17 For all Community uses
            Including amendments to 3 July 2017
The Noosa Plan



                                                                          column 1                                                      column 2
                                                                      Specific Outcomes                                  Probable solutions (if code assessment)
                                                  14.450 Effects of use
                                                  Electricity supply infrastructure
                                                  O1 The development does not adversely                              S1.1 No solution provided
                                                  impact on existing or future electricity supply
                                                  infrastructure;
                                                  AND                                                                S2.1 Development for uses adjacent to or
                                                  O2 All uses and works maintain an adequate                         within 50m of an existing electricity substation
                                                  safe distance from electrical infrastructure                       incorporates noise attenuation measures to
                                                  including substations, overhead powerlines,                        mitigate noise impacts;
                                                  power poles and transformers.                                      AND
                                                                                                                     S2.2 Buildings and structures (including
                                                                                                                     swimming pools, sheds, tennis courts and
                                                                                                                     outbuildings) are not constructed under
                                                                                                                     overhead electricity transmission lines, or within
                                                                                                                     electricity easements;
                                                                                                                     AND
                                                                                                                     S2.3 A minimum separation distance is
                                                                                                                     maintained from the electricity transmission line
                                                                                                                     to the closest boundary of habitable buildings
                                                                                                                     and child activity areas, as follows—
                                                                                                                     a)     20m for transmission lines up to 132kV;
                                                                                                                     b)     30m for transmission lines between 133kV
                                                                                                                            and 275kV; and
                                                                                                                     c)     40m for transmission lines greater than
                                                                                                                            275kV.
                                                  Road network function
                                                  O3 The use does not have an adverse impact                         No solution provided
                                                  on the safety and efficiency of the road
                                                  network14;
                                                  AND
                                                  O4 The surrounding road system is capable
                                                  of accommodating additional traffic generated
                                                  by the proposal.
                                                  Noise and visual amenity
                                                  O5 The use does not have a significant                             S5.1 If the use involves outdoor courts
                                                  adverse impact on the amenity enjoyed by                           including tennis courts, half courts or netball
                                                  users of adjoining or nearby premises;                             courts—the use complies with the requirements
                                                                                                                     in Section 2 of PSP8 Tennis and Other Courts.
                                                  AND
                                                                                                                     S6.1 Noise sensitive Community Uses are not
                                                  O6 Development is designed and sited to                            located adjacent to the major road network;
                                                  avoid adverse noise impacts associated with                        OR
                                                  neighbouring noise sources by—                                     S6.2 Double glazed windows are used to
                                                  a)    locating the use away from major noise                       mitigate noise;
                                                        sources such as busy roads or rail                           OR
                                                        corridors; or                                                S6.3 Solid concrete articulated fences are
                                                  b)    applying appropriate noise attenuation                       constructed on-site to attenuate noise;
                                                        measures into the development.                               AND
                                                                                                                     S6.4 Where the site adjoins properties in a
                                                                                                                     residential zone—
                                                                                                                     a) any lit sports courts are located at least 60m
                                                                                                                         from the external wall of an existing or
                                                  14
                                                       PSP 1 details information Council may request including detailed traffic studies.




                                                                                                              14-34
                                                                                                        Community Uses Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.