Council archive · source document
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Probable solutions (if code assessment)
The Noosa Plan
Mechanical plant and equipment and storage
areas
O17 Mechanical plant and equipment S17.1 Mechanical plant and equipment are—
(including air conditioning equipment) and a) located more than 2m from any property
storage areas are designed and located to— boundary;
a) avoid adverse visual impacts when viewed b) where located at ground level, screened
from the street and adjoining properties; by fencing 1.5m in height or dense
and vegetation of at least 1.5m in width
b) be visually integrated with the building incorporating grouped trees and shrubs
design. with maximum separation distance of 1m
measured from the centre of the tree or
scrub; and
c) visually integrated into the line and plane
of the building and roof design and do not
project beyond the height or width of the
building when viewed from the street and
adjoining properties.
Transport and access
O18 Premises have accessibility to public S18.1 Safe and convenient pathway access is
transport and cycling and walking is promoted. provided from the site to link to existing pathway
networks that services public transport facilities;
OR
S18.2 Direct pathway access is provided to the
public transport facility if the facility is contained
on site or within 50m from the property
boundary.
O19 Community Uses are designed and S19.1 Safe and convenient cycle access to and
constructed to encourage users of the from the site from the existing road and bicycle
development to access the site by means of foot network, and safe pathway movement within the
or bicycle through provision of appropriate end- site is provided;
of-trip facilities including bicycle parking and AND
shower/change rooms S19.2 Secure and convenient parking space for
bicycles is provided on site in accordance
Figure 14-2 Minimum Bicycle Parking
Figure 14-2 Minimum Bicycle Parking
Requirements and AS2890.3 Bicycle Parking
Requirements
Facilities;
Use Minimum bicycle parking AND
Education 1 bicycle parking space per S19.3 Where at least 5 bicycle parking spaces
Types 2, 3 or 30m2 or part thereof of are required in accordance with Figure 14-2
4 gross floor area. Minimum Bicycle Parking Requirements, end-of-
Open Space 1 bicycle parking space per trip cycle facilities are provided at the following
200m2 or part thereof of site rate:
Type 1
area a) 1 locker per 2 bicycle parking spaces; and
b) 1 shower cubicle with ancillary change
Wellbeing 1 bicycle parking space per
rooms per 10 bicycle spaces or part
Types 1, 2 or 30m2 or part thereof of
thereof;
3 gross floor area.
AND
S19.4 Bicycle parking spaces and cyclist
facilities are designed in accordance with
AUSTROADS Guide to Traffic Engineering
Practice, Part 14 – Bicycles, Section 10;
AND
S19.5 On-site pedestrian facilities such as
seating and shade structures are provided in
developments for the convenience of persons
walking to the site.
14-37
Community Uses Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.