                                                  Table 14-24 — For All Residential Uses
            Including amendments to 3 July 2017
The Noosa Plan



                                                                          column 1                                                    column 2
                                                                      Specific Outcomes                                Probable solutions (if code assessment)

                                                  14.46         Effects of use
                                                  Electricity supply infrastructure
                                                  O1 The development does not adversely                             S1.1 No solution provided
                                                  impact on existing or future electricity supply
                                                  infrastructure;
                                                  AND
                                                  O2 All uses and works maintain an adequate                        S2.1 Development for uses adjacent to or
                                                  safe distance from electrical infrastructure                      within 50m of an existing electricity substation
                                                  including substations, overhead powerlines,                       incorporates noise attenuation measures to
                                                  power poles and transformers.                                     mitigate noise impacts;
                                                                                                                    AND
                                                                                                                    S2.2 Buildings and structures (including
                                                                                                                    swimming pools, sheds, tennis courts or
                                                                                                                    outbuildings) are not constructed under
                                                                                                                    overhead electricity transmission lines, or
                                                                                                                    within electricity easements;
                                                                                                                    AND
                                                                                                                    S2.3 A minimum separation distance is
                                                                                                                    maintained from the electricity transmission
                                                                                                                    line to the closest boundary of habitable
                                                                                                                    buildings and child activity areas, as follows—
                                                                                                                    a)     20m for transmission lines up to 132kV;
                                                                                                                    b)     30m for transmission lines between
                                                                                                                           133kV and 275kV; and
                                                                                                                    c)     40m for transmission lines greater than
                                                                                                                           275kV.
                                                  Water supply and conservation
                                                                                                                    S3.1 & S4.1 For a Class 1 building18 other than
                                                  O3 On-site water storage is designed and
                                                                                                                    a Detached house , outside a reticulated
                                                  operated to support the efficient use of water;
                                                                                                                    water service area, a rainwater tank is to be
                                                                                                                    installed with the following minimum storage
                                                  AND
                                                                                                                    capacities—
                                                  O4 On-site water storage is adequate for                                 a) Where no more than 3 bedrooms –
                                                  occupants every day use and fire fighting                                    45,000 litres; or
                                                  purposes.                                                                b) Where more than 3 bedrooms –
                                                                                                                               60,000 litres;
                                                                                                                    AND
                                                                                                                           c) There is to be on the lot a dam,
                                                                                                                               swimming pool or water tank
                                                                                                                               accessible for use by the fire brigade
                                                                                                                               that contains at least 5,000 litres of
                                                                                                                               water.

                                                                                                                    Editor’s note:
                                                                                                                    The 5,000 litres required can be included
                                                                                                                    within the water required in S3.1 or S4.1
                                                                                                                    providing it is accessible for the purpose of fire
                                                                                                                    fighting at all times and not used for other
                                                                                                                    domestic purposes.



                                                  18
                                                       Class 1 Buildings are defined under the Building Code of AustraliaNational Construction Code



                                                                                                             14-46
                                                                                                      Residential Uses Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.