2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections

of 862

Text shows just the words. Original shows the document exactly as it was published.

                                                                     column 1                                            column 2
            Including amendments to 3 July 2017




                                                                 Specific Outcomes                        Probable solutions (if code assessment)
The Noosa Plan




                                                  Site layout
                                                  O23 For caravan parks—                                S23.1 The entrance road width meets the
                                                  a)    the entrance and exit is of sufficient width    following minimum requirements—
                                                        to allow for 2 vehicles towing caravans to      a)    for a two-way entrance/exit road– 7m; or
                                                        safely pass one another;                        b)    for a one-way entrance road– 7m if
                                                  b)    a short term parking area is provided near            incorporating a standing bay, or
                                                        the office to allow for check-in and check-           otherwise– 4m; or
                                                        out; and                                        c)    for a one-way exit road– 4m;
                                                  c)    the internal road layout and design caters      AND
                                                        for all anticipated vehicle use enabling        S23.2 A short term standing area with
                                                        suitable manoeuvrability and safety and         minimum dimensions of 4m x 20m is provided
                                                        avoiding congestion;                            either as a separate bay or as part of a one-
                                                                                                        way entrance road;
                                                                                                        AND
                                                                                                        S23.3 For internal roads—
                                                                                                        a)    vehicular access is provided to each
                                                                                                              caravan, tent and cabin site;
                                                  AND                                                   b)    emergency vehicles can access all
                                                                                                              buildings and each caravan, tent and
                                                                                                              cabin site;
                                                                                                        c)    roads have a drained all weather surface;
                                                                                                              and
                                                                                                        d)    roads have a minimum width of 4m if
                                                                                                              one-way or 6m if two-way.

                                                  O24 The office is located near the entrance to        S24.1 No solution provided
                                                  the premises.
                                                  Parking and manoeuvring
                                                  O25 Sufficient carparking, wash-down and              No solution provided
                                                  manoeuvring areas are provided to meet the
                                                  needs of residents, visitors and other users.
                                                  Pedestrian access
                                                  O26 Safe and effective pedestrian access is           S26.1 Pedestrian pathways are not less than
                                                  provided to the office and any associated shop,       1m wide and provide convenient linkages to
                                                  common toilets, ablutions, laundry buildings and      park facilities;
                                                  clothes drying areas.                                 AND
                                                                                                        S26.2 Speed control devices are provided
                                                                                                        along internal access roads and comply with
                                                                                                        Section 2.13 of Queensland Streets.
                                                  Lighting
                                                  O27 All internal caravan park roads and areas of      No solution provided
                                                  pedestrian activity have safe and practical
                                                  lighting, which is designed to minimise light
                                                  nuisance to individual sites and to other areas
                                                  within and outside the park.




                                                                                                     14-82
                                                                                         Visitor Accommodation Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.