            Including amendments to 3 July 2017




                                                                 Specific Outcomes                              Acceptable solutions (if accepted
The Noosa Plan



                                                                                                              development subject to requirements)
                                                                                                             Probable solutions (if code assessment)
                                                                properties

                                                  AND

                                                  O3 Finished surface levels ensure land is free          S3.1 No solution provided
                                                  draining.

                                                  O4 Filling or excavation does not adversely             S4.1 Fill material placed over services does not
                                                  affect sewer, stormwater or water utility               impose any additional surcharge loading on the
                                                  infrastructure.                                         service.

                                                  Editor’s note                                           S4.2 Where excavation is carried out-
                                                  Council encourages building methods that avoid the      c)    a minimum cover of 600mm is maintained
                                                  use of fill, such as suspended floor construction and         around all utility infrastructure (to top,
                                                  stepping down slopes rather than cutting and filling.
                                                                                                                sides and base of services); or
                                                                                                          d)    a retaining wall is provided to support the
                                                                                                                soil surrounding the service;
                                                                                                          AND
                                                                                                          S4.3 Compaction with a vibrating roller is not
                                                                                                          carried out within 600mm of any utility
                                                                                                          infrastructure.
                                                  O5 Development does not adversely impact                S5.1 Buildings or other structures within the
                                                  on the Lake Macdonald water supply.                     Lake Macdonald catchment (indicated on Figure
                                                                                                          14-15) are located above the 98.5m AHD level.
                                                  Electricity supply infrastructure
                                                  O6 Uses and works maintain an adequate                  S6.1 Buildings and structures (including
                                                  safe distance from electrical infrastructure            swimming pools, sheds, tennis courts or
                                                  including substations, overhead powerlines,             outbuildings) are not constructed under
                                                  power poles and transformers.                           overhead electricity transmission lines, or within
                                                                                                          electricity easements.
                                                  Steep slopes and Landslide hazard areas
                                                  O7 Detached houses and associated uses                  S7.1 If on premises identified as a Landslide
                                                  are sited or constructed to maintain the safety of      Hazard Area on Overlay Maps OM1.3–9.3 or on
                                                  people and property from the risk of landslide.         steep slopes, the use does not—
                                                                                                          a)   involve the removal of vegetation other
                                                                                                               than grass from use areas;
                                                                                                          b)   involve excavating or filling of more than
                                                                                                               50m3 of material (other than placement of
                                                                                                               topsoil not exceeding 100mm in depth
                                                                                                               relative to natural ground level;
                                                                                                          c)   involve cut or fill with a vertical depth of
                                                                                                               more than 2m relative to natural ground
                                                                                                               level;
                                                                                                          d)   redirect or impede water flows in an
                                                                                                               existing watercourse or stormwater drain;
                                                                                                               or
                                                                                                          e) involve construction of an on-site effluent
                                                                                                               disposal system;
                                                                                                          OR

                                                                                                          S7.2 A site specific geo-technical report
                                                                                                          prepared by a registered professional engineer
                                                                                                          either—
                                                                                                          a)    certifies that the site is not at risk from


                                                                                                       14-102
                                                                                                Building Works Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.