            Including amendments to 3 July 2017




                                                                Specific Outcomes                          Acceptable solutions (if accepted
The Noosa Plan



                                                                                                         development subject to requirements)
                                                                                                        Probable solutions (if code assessment)
                                                  14.96    Effects of use
                                                  Lighting
                                                  O19 Lighting associated with the use or works       S19.1 A 1.5m landscaped buffer separates any
                                                  does not have an adverse impact upon the            private tennis court or other sports court from
                                                  amenity enjoyed by users of adjoining or nearby     side property boundaries;
                                                  premises nor do it cause unreasonable               AND
                                                  disturbance to local fauna..
                                                                                                      S19.2 Tennis courts or half courts are fenced
                                                                                                      with fencing of 3.6m in height for a full sized
                                                                                                      court or 2.4m in height for a half court;
                                                                                                      AND
                                                                                                      S19.3 Any lit tennis court or other sports court is
                                                                                                      located at least 60m from the external wall of an
                                                                                                      existing or approved residential dwelling on an
                                                                                                      adjacent or nearby lot (as measured from the
                                                                                                      centre line of the court);
                                                                                                      AND
                                                                                                      S19.4 For lighting–
                                                                                                      a)     the vertical illumination resulting from
                                                                                                             direct, reflected or other incidental lighting
                                                                                                             emanating from the site does not exceed
                                                                                                             8 lux when measured at any point 1.5m
                                                                                                             outside the boundary and at any level
                                                                                                             from ground level upward;
                                                                                                      b)     all flood lighting is hooded or baffled to
                                                                                                             direct lighting downward or is of a type
                                                                                                             that gives no upward component of light
                                                                                                             when mounted horizontally;
                                                                                                      c)     all flood lighting is setback a minimum of–
                                                                                                               i)    6m from the boundary to any
                                                                                                                     frontage; and
                                                                                                               ii) 2m to any other boundary; and
                                                                                                      d)     lighting structures are not more than 8m in
                                                                                                             height.
                                                  Environmental Protection
                                                  O20 The design, siting and construction of          S20.1 Where there is an existing building
                                                  buildings and structures minimise the clearing of   envelope on the lot that contains vegetation
                                                  vegetation and where there is an existing           protection measures, clearing of native
                                                  preliminary approval for the property that          vegetation and building works do not extend
                                                  contains vegetation protection measures, the        beyond the building envelope, except for the
                                                  proposal is consistent with those measures.         purposes of a driveway access;
                                                                                                      OR

                                                                                                      S20.2 Where there is no building envelope
                                                                                                      existing on the lot, clearing of native vegetation,
                                                                                                      other than for a driveway access does not
                                                                                                      extend beyond—
                                                                                                      a) 30m of a building or 10m of a structure on
                                                                                                          lots greater than 10ha;
                                                                                                      b) 10m of a building or structure on lots 10ha
                                                                                                          or less but more than 0.3ha; or
                                                                                                      c) 3m of a building or structure on lots 0.3ha or

                                                                                                  14-108
                                                                                           Building Works Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.