                 column 1                                            column 2
             Specific Outcomes                          Acceptable solutions (if accepted




                                                                                                                    Including amendments to 3 July 2017
                                                     development subject to requirements)




                                                                                                        The Noosa Plan
                                                    Probable solutions (if code assessment)
                                                     horizontal centres, with a maximum height of
                                                     0.75m, to avoid clumping and to retain
                                                     sightlines.

O6 Street trees and plantings in towns and       S6.1 Street trees and trees in carparking areas
villages, carparks and other areas where         achieve a maximum of 900mm clear trunk height
potential conflicts with vehicles and            for a 2.0m high tree at planting and are able to
pedestrians are evident, are planted so as to    attain a clear trunk height of 1900mm on maturity;
maximise vehicle and pedestrian safety.          AND
                                                 S6.2 All scrub planting to be a maximum height of
                                                 700mm from the road pavement (not top of kerb).
Services and utilities
O7 All landscaping works maintain                S7.1 Plant species used in landscaping adjacent
adequate safe distance from services and         to substations, or adjacent to or on electricity
utilities including substations, overhead        transmission line easements, are less than 4m
powerlines, power poles and transformers,        high at maturity and do not encroach within 3m of
street lamps, stormwater catchment pits, and     a substation boundary;
underground services and utilities.              OR
                                                 S7.2 For trees higher than 4m, trees are planted
                                                 at a distance from any part of an electricity
Figure 14-17
                                                 transmission line at least equal to the expected
                                                 height of the tree at maturity (see Figure 14-17);
                                                 AND
                                                 S7.3 For power lines that connect to a premises,
                                                 the height of plant species at maturity provides for
                                                 a 2m clearance below the power line; (see Figure
                                                 14-18)
                                                 AND
                                                 S7.4 Trees and large scrubs are located a
                                                 minimum of—
                                                 a)    5m from electricity poles and pillars;
                                                 b)    4m from street lamps;
Figure 14-18                                     c)    2m from stormwater catchment pits; and
                                                 d)    2m from underground services and utilities;
                                                 AND
                                                 S7.5 Plants are located to enable tradespersons
                                                 to access, view and inspect service meters, such
                                                 as water and electricity meters;
                                                 AND
                                                 S7.6 Root barriers are installed around trees that
                                                 are located within 3m of any infrastructures or that
                                                 have potentially invasive roots.




                                               14-137
                                          Landscaping Code

Used in these records

About this file

File size
9.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.