Council archive · source document
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions (if code assessment)
Including amendments to 3 July 2017
The Noosa Plan
Figure 14-38
AND
S12.8 Walkways serving jetties have at least
one rigid handrail fitted and the walkway is a
minimum width of 750mm and a maximum width
of 1.5m where—;
a) the walking surface of the jetty is
constructed level with the top of the
revetment wall;
b) water reticulation systems are fitted with a
mechanical backflow prevention device;
and
c) electrical reticulation systems carrying
electricity in excess of 24 volts are not to
extend beyond the revetment wall;
AND
S12.9 Any lower-level platform, or siding, along
the jetty walkway has a maximum width of
500mm and does not exceed 2m2 and does not
interfere with the prolongation of boundaries as
indicated by Probable solutions 11.1-11.3;
O13 Pontoons and boat ramps are not
constructed in Noosa Waters Estate. S13.1 No solution provided
14.169 Boat lifting devices
O14 Boat lifting devices are only constructed in S14.1 Boat lifting devices are only located in
the absence of a boat ramp and are designed conjunction with an approved jetty where
and located to— a) the boat lifting device does not extend into
a) ensure that unacceptable risks to personal the watercourse beyond the end of the
and public safety are unlikely to be approved jetty;
caused; b) the boat lifting device is no greater than 4m
b) avoid cluttering of the watercourse; in width or for a jetty hoist 2m in width;
c) ensure that visual amenity of the c) the boat lifting device is located adjacent to
foreshore and watercourse is maintained; walkway to the jetty and is generally
and perpendicular to the revetment wall;
d) ensure the structure integrity of the works d) the boat lifting device is not located on the
are maintained and not compromised. jetty head; and
e) the outermost projection of the boatlifting
device of jetty hoist is setback a minimum
of 1m from the prolongation of the
boundaries;
AND
S14.2 Only one boat lifting device and a jetty
hoist per jetty;
14-173
Watercourses Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections.pdfRelated documentPublic source context ↗
2017-11-07-p-e-committee-attachment-1-to-item-1-amendments-for-multiple-housing-type-2-duplex-minor-corrections-pdfRelated documentPublic source context ↗
About this file
- File size
- 9.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.