                                                                            column 1                                                         column 2
            Including amendments to 3 July 2017
The Noosa Plan



                                                                      Specific Outcomes                                  Probable solutions (if code assessment)
                                                  electricity, street lighting and telecommunication                provided underground;
                                                  services—
                                                                                                                    OR
                                                  a)        meets the needs of users;
                                                  b)        ensures health, safety and convenience of               S16.2 For lots elsewhere—power supply and
                                                            the community;                                          communications infrastructure are provided
                                                  c)        protects the natural environmental values               underground unless—
                                                            of the site and surrounds, including visual             a)     located in the Rural Zone or Rural
                                                            amenity and native vegetation;                                 Settlement Zone and where not in a
                                                  d)        are cost effective over their life cycle;                      Bushfire Hazard Area as defined on
                                                  e)        minimises adverse impacts to the                               Overlay Maps OM1.4-OM9.4;
                                                            environment (including the amenity of the               b)     new low voltage lines can be strung from
                                                            local area) in the short and long term; and                    poles carrying existing high voltage lines;
                                                  f)        ensures that the existing systems are                          or
                                                            upgraded or relocated to be capable of                  c)     no extensions to the existing reticulation
                                                            supporting the proposed development;                           network is necessary; or
                                                                                                                    d)     it is necessary to cross a body of water;
                                                                                                                    AND
                                                                                                                    S16.3 Street lighting is provided in accordance
                                                                                                                    with Section 3.19 of PSP5 Engineering Design
                                                                                                                    Standards – Roads, Drainage and Earthworks;
                                                                                                                    AND
                                                                                                                    S16.4 For lots not within a sewerage service
                                                                                                                    area—the lot has sufficient area and other
                                                                                                                    attributes to ensure sustainable on-site sewerage
                                                                                                                    disposal39;
                                                                                                                    Editor’s note:
                                                                                                                    PSP24 – Effluent Disposal details requirements for the
                                                                                                                    design and siting of effluent disposal systems where
                                                                                                                    located outside a sewerage service area. Compliance
                                                                                                                    with PSP24 will be considered as part of Council’s
                                                                                                                    assessment of the plumbing and drainage application.




                                                                                                                    S17.1 Components of the essential network
                                                                                                                    infrastructure that are likely to fail or may result in
                                                                                                                    contamination when inundated by flood water—
                                                  O17 Essential network infrastructure (e.g.                        a)    comply with Table 13.12; or
                                                  electricity, water supply, sewerage and                           b)    are designed and constructed to exclude
                                                  telecommunications) maintains effective                                 water inundation or infiltration and resist
                                                  function during and immediately after flood                             hydrostatic and hydrodynamic forces as a
                                                  events.                                                                 result of inundation.

                                                  39
                                                       PSP1 details information Council may request including an effluent disposal report.




                                                                                                              14-182
                                                                                                      Reconfiguring a Lot Code

Used in these records

About this file

File size
9.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.