Original source · versioned page text
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
Flooding and drainage 59
Including amendments 3 July 2017
The Noosa Plan
O7 Buildings and other works are designed and S7.1 For new buildings or structures or
sited to— additions of more than 50m2 gross floor area
a) provide flood free access to premises and to an existing building or structure, floor levels
flood free habitable areas; for habitable rooms are—
b) allow only minor, short term and infrequent a) for areas where minimum floor levels
flooding of non-habitable areas; are available—not less than the
c) ensure carparking areas can be adequately specified level;
drained; b) for areas where flood modelling is
d) ensure drainage does not adversely impact available—a minimum of 300mm
upon other premises; and above the modelled flood level; and
e) ensure filling or excavation does not c) for areas where flood modelling is not
adversely impact upon other premises by— available, a minimum of 300mm above
i. causing ponding of water on the site the highest known flood level;
or nearby land; AND
ii. increasing flooding, which adversely S7.2 Where Council infrastructure is
affects the safety or use of any land available—
upstream and downstream; and a) any drainage (from buildings and land)
iii. adversely affecting the flow of water flows to that infrastructure; and
in any overland flow path. b) the infrastructure has the capacity to
accept any additional loading;
AND
S7.3 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping; or
S7.4 Basements for residential uses have
flood immunity above the 1%AEP defined
flood event where alternative means to
mechanical pumping are used to achieve
such immunity; or
S7.5 Basements for non-residential uses
have flood immunity above the 1%AEP
defined flood event that may be achieved by
means of mechanical pumping where the
mechanical feature is installed with adequate
holding tanks and an alternative back up
power source.
59
Information on minimum floor levels and flood levels for some parts of the Shire is available from Council. These
provisions are not limited to areas shown as Flood Hazard Areas on overlay maps OM1.3-9.3.