Original source · versioned page text
Approved Plans - MCU20/0154
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn CONSTRUCTION NOTES : 20,890 GENERAL NOTES
1. EXTERNAL WALLS = 220mm (110mm BRICK, 8,270 3,600 6,150 2,870 1. PROVIDE COLD WATER CONNECTION & G.P.O.
40mm CAVITY, 70mm FRAME) TO DISHWASHER SPACE.
2. N3 WIND DESIGN SPEED NOMINATED. 2. VENTILATION TO WC TO BE AN EXHAUST FAN
3. WC DOOR TO HAVE EXTERNAL REMOVABLE 220 3,470 70 4,290 220 220 3,520 90 2,100 220 IN ACCORDANCE WITH BCA-F4.5 & AS-1668.2
HINGES IN ACCORDANCE WITH BCA-3.8.3.3. 3. THE NUMBER OF DOORS AND WIDTH OF DOORS
220 7,830 220 WILL BE DETERMINED BY THE CABINETMAKER TO
ARTICULATION JOINTS OPTIMIZE THE FUNCTIONALITY OF THE CABINETRY.
AJ = Articulation joint location nominated on drawings.
Builder to provide extra Articuation joints over & above 220 2,700 70 10,240 90 1,480 70 5,800 220 EXPANSION JOINTS
EJ = Expansion joint location for ceiling & floor
what is nominated on drawings where necessary to tiles.
comply with the Building Code of Australia, Engineers
structural design requirements, soil report
recomendations and site classification requirements
X
slab edge
HC
D.P D.P
18-18SW 09-06SW OBS
D.P
lintel
450
04-06 NICHE
220
70 1,930 220
220
220
220
220
220
roll
holder
1,800 sliders
fixed glass
shr
clothesline
wc
AL FRESCO
robe
820 CSD
2100
2,400
12-18SW
plaster lined ceiling
4,530
towel
BED. 2 vanity rail
3,140
4,080
4,080
21-24 SD
21-30 STACKER
FAMILY RM MASTER BED
4,080
carpet
4,010
4,010
tiled carpet
1,140
4,840
D.P
1,540 70
820 1,140
WIR
04-06 NICHE
70
70
720
09-06SW D.P 12-15SW OBS
21-30 STACKER
1525 bath
800 shr 820
1,630
2,000
820 CSD
vanity 820
530
220
220
70
70 70
70
220
brm linen
8,580
G.HWS
1,000
800
10,520
10,520
620 620 MH
720 CSD
towel
70
720
720
3,800
rail
70
4,500
WIP
900
900
200 wide b"bar ohang
roll
1,700
holder
tub
OBS
930
ohs
720
wc
2,100
sink wm
4,500
gas bottles by owner
range with canopy RH
900mm freestanding
ohs
2,700
DINING DOUBLE GARAGE
4,500
820
530
70
70
robe 880
70
STUDY NOOK dw tiled
1,110 200
6,440
hamper
1,600 sliders
6,000
6,000
70
820 ENTRY
70
70
mw
2,130
tiled
1,000
bulkhead over
ohc
140
ref
3,800
800
220
220
BED. 3 BED. 4 ohc's fg 820
3,200
3,000
3,000
carpet carpet
1,430 70
1,200 sliders 18-12SW 18-18SW
750
HC
1,500 220
1,500 220
1,000
fc sheet ceiling VERANDAH
850
robe
D.P M. BOX
lintel tiled lintel
150
D.P
D.P
D.P
18-18SW 18-18SW 2148 panel lift door - remote
220
220
220
220
220
500
500
220
220
150sq.timber
X
post - 2
smoke detectors to be hard
220 1,730 70 4,270 70 wired with battery backup
4 & interconnected with one another
1 3 220 1,730 70 1,200 70 3,000 70 2,600 4,270 140 1,430 70 5,800 220
2
220 3,000 70 3,000 70 6,870 70 1,500 70 5,800 220 AREAS: SQ METRES:
LIVING 143.6
530
220 3,000 70 3,000 70 220 1,990 150 3,260 150 1,990 220 5,800 220 GARAGE 38.4
PORCH 7.5
ALFRESCO 14.7
FLOOR PLAN 7,110 7,540 6,240
TOTAL = 204.2 m2
SCALE 1:100 20,890
-
APPROVED PLAN
MCU20/0154
NOTES PLAN LEGEND PLEASE READ CAREFULLY NOOSACLIENT:
COUNCIL
1. Written dimensions take precedence over scale.
10. Protection against subterranean termites shall be in accordance with AS
3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE 22COUTTS
D. FEBRUARY
& A.2021
BRETT
CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL -
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry Lot 31 Butcherbird Lande
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. RIDGEWOOD
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S 20L031BU
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Springleigh 204 Classic No.
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2017 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
PRELIM ISSUE 1 : 03/11/20 4 OF 08
GSPublisherVersion 0.0.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.