     bushland are retained and protected           gullies, waterways, wetlands, vegetation and
     from the impacts of development. Any          bushland.
     unavoidable impacts are minimised
     through location, design, operation and
     management requirements.

 o) Native vegetation between buildings and        Complies: There is no vegetation of significance
    in the public realm enhances the amenity       located on the site. The proposal will provide for
    and supports local wildlife.                   a generous landscaped setting that is capable of
                                                   accommodating large trees.

Basements

AO16
Basements:

a)    are limited to one access a maximum of 6 metres wide; and
b)    do not encroach into building setback areas.

PO16
Basements:

a)    visually integrate with the building;
b)    do not dominate the street or building design;
c)    are screened through landscaping; and
d)    do not present as a storey to the street.

The proposed building includes a basement that has an outermost projection of 0.19m from the
southeast side boundary and consequently encroaches into the side setback area. Despite the non-
compliance with Acceptable Outcome AO16 of the Medium Density Residential Zone Code, the
proposed basement complies with the corresponding Performance Outcome PO16 for the following
reasons:
a) it visually integrates with the building as it is situated beneath the envelope of the building and
    limited to a 4.5m wide opening facing the street;
b) it will not dominate the street or the building design as it is setback 6m from the road boundary
    and the ground level will be retained around the structure;
c) the basement will be screened through tiered landscaping opportunities within a 6m setback that
    will generally be uncompromised by infrastructure;
d) while the basement would have a maximum floor to ceiling height of 1.256m above the natural
    ground level for a small portion at the northern corner of the building, this minor exceedance
    would not be visually perceivable from the street for the following reasons:-
        i.   it is a minor 256mm exceedance above the natural ground level;
       ii.   the land surrounding the basement will be filled so that it is level with the finished ceiling
             height of the basement and will become the new ground level (refer to Figure 4 below);
             and
      iii.   the front setback area will be landscaped with a tiered plantings comprising of ground
             covers, shrubs and trees and will further visually conceal the extent of the basement.




                                                                                               Page 15 of 17

Used in these records

About this file

File size
4.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Assessment Report.pdf · 4.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.