Attachment D - Waste Management Report
4. \\Waste Storage Details 4.1. Waste Storage Requirements The waste storage requirements for lower floor trade hubs and the ground floor warehouse and micro-warehouse are outlined in tables 4.1 and 4.2 below. Table 4.1: Lower Floor-Trade hubs Waste Storage Requirements Bin Size (L)/ Width Depth Waste Stream Equipment Quantity cnenm per bin per bin onli Type (mm) (mm) General Waste 1100 2 1330 1240 1070 2.65 Recycling 1100 1 1330 1240 1070 1.33 Paper & Cardboard 1100 1 1330 1240 1070 1.33 Bin tug 1 940 880 1930 1.70 Total Footprint Required Excluding Circulation (m?): 7.01 A bin tug shall be provided in a location accessible to the operator for assisting with the transfer of bins up/down the ramp for collection. Refer to Appendix B for the recommended bin tug. Table 4.2: Ground floor-Warehouse and Micro-warehouse Waste Storage Requirements Width Depth Waste Stream Bin Size (L) Quantity peo per per bin per bin pooreanl bin (mm) (m?) (mm) (mm) General Waste 1100 2 1330 1240 1070 2.65 Recycling 1100 2 1330 1240 1070 1.33 Paper & Cardboard 1100 1 1330 1240 1070 1.33 Total Footprint Required Excluding Circulation (m”): 6.63 20755W-ROIFO3 58 Rene Street, Noosaville QLD 12