Council archive · source document
Att 2- Engineering · MCU23/0038.02
Compliance certificate for
Form 15 building design or specification
This form is to be used by an appointed competent person for the purposes of section 10 of the Building Act 1975 and sections 73
and 77 of the Building Regulation 2021 (Design-specification certificate) stating that an aspect of building work or specification will, if
installed or carried out as stated in this form, comply with the building assessment provisions.
Additional explanatory information is included in the Appendix at the end of this form.
1. Property description Street address (include number,street, suburb / locality and postcode)
This section need only be completed if
details of street address and property
description are applicable.
State: Postcode :
E.g. In the case of (standard/generic)
pool design/shell manufacture and/or
patio and carport systems this section
Lot and plan details (attach list if necessary)
may not be applicable.
Lot No: SP/RP :
The description must identify all land the
subject of the application Local government area the land is situated in?
.
The lot & plan details (eg. SP / RP) are
shown on the title documents or a rates notice.
If the plan is not registered by title, provide
previous lot and plan details.
2. Description of aspect/s
certified
Clearly describe the extent of work covered by
this certificate. e.g all structural aspects of the
steel roof beams.
3. Basis of certification
Australian Standards (list) AS/NZS 4600-2018, AS/NZS 1170.0,.1-2002, 1170.2-2021, 1170.3-2003,
Detail the basis for giving the certificate and the
extent to which tests, specifications, rules,
standards, codes of practice and other
1170.4-2007, AS2870-2011, AS3600-2018, AS5216-2021
publications were relied upon.
National Construction Code of Australia NCC Building Classification =
Region AS1170.2 = Annual Probability Exceedance wind =
NCC Importance Level = NCC Equivalent Wind class =
Factor for Region =
Regional 3 s Gust Wind Speed for annual probability of exceedance V R= m/s
Wind directional multipliers for the 8 cardinal directions Md =
Terrain/Height multiplier (Mz, Cat) = Shielding Multiplier M s=
Topographic multiplier Mt = Design Wind Speed = m/s
External Pressure Coefficent cpe =
Internal Pressure Coefficent cpi =
Design Roof Live Load =
Building Regulation 2021 * Section 73 and 77 * Form 15 * Version 2 * March 2023 Page 1 of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 2- Engineering.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (small file)
- File type