Original source · versioned page text
20230023-231215-Rev C
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
PROPOSED UNIT DEVELOPMENT
206 DAVID LOW WAY PEREGIAN BEACH QLD 4573
LOT 54 P9319
CIVIL WORKS
SCHEDULE OF DRAWINGS
DWG No. TITLE
WAY
001 COVER SHEET & LOCALITY PLAN
OW
002 GENERAL NOTES
ID L
003 EXISTING LAYOUT PLAN
010 OVERALL LAYOUT PLAN
DAV
020 BULK EARTHWORKS LAYOUT PLAN
021 BULK EARTHWORKS SECTIONS
030 EROSION AND SEDIMENT CONTROL LAYOUT PLAN SAND
PIPER
031 EROSION AND SEDIMENT CONTROL DETAILS CCT
040 SITEWORKS AND DRAINAGE LAYOUT PLAN
041 STORMWATER LONGITUDINAL SECTION
045 STORMWATER CATCHMENT LAYOUT PLAN LOT 54
060 VEHICLE SWEPT PATHS PLAN - SHEET 1 OF 8
ON P9319
061 VEHICLE SWEPT PATHS PLAN - SHEET 2 OF 8
T
AER S
062 VEHICLE SWEPT PATHS PLAN - SHEET 3 OF 8
063 VEHICLE SWEPT PATHS PLAN - SHEET 4 OF 8
064 VEHICLE SWEPT PATHS PLAN - SHEET 5 OF 8
PLOV
065 VEHICLE SWEPT PATHS PLAN - SHEET 6 OF 8
066 VEHICLE SWEPT PATHS PLAN - SHEET 7 OF 8
Y
WA
067 VEHICLE SWEPT PATHS PLAN - SHEET 8 OF 8
068 VEHICLE SWEPT PATHS VERTICAL PLAN - SHEET 1 OF 2
OW
069 VEHICLE SWEPT PATHS VERTICAL PLAN - SHEET 2 OF 2
ID L
DAV
LOCALITY PLAN
SCALE 1:1000
North Point Approved Project Address Title
206 DAVID LOW WAY COVER SHEET & LOCALITY PLAN
N
PEREGIAN BEACH QLD 4573
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 31.03.23 OPW ISSUE QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
001 C
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK the revision description.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.
Full text of sections 2 to 6 (of 22)
Section 2
GENERAL NOTES ANDSTOCKPILE ON SITE OR REMOVE FROM SITE AS DIRECTED. STRUCTURAL FILL. REQUIREMENTS OF THE GEOTECHNICAL ENGINEER. TEMPORARY
19. DRAWINGS TO BE READ IN CONJUNCTION WITH ARCHITECT, SURVEYOR, 3. UNSUITABLE NATURAL MATERIALS SUCH AS SATURATED, LOOSE OR UNSURCHARGED CUTS IN LOOSE TO VERY LOOSE SAND TO TYPICALLY
1. ALL DIMENSIONS SHOWN ARE IN METERS UNLESS OTHERWISE SHOWN. HYDRAULICS, ETC. CONSULTANT AND CONTRACTOR DRAWINGS. SOFT MATERIALS ENCOUNTERED SHOULD BE REMOVED DURING BE FORMED AT 1V:2H, AND IN MEDIUM DENSE SAND AT 1V:1H FOR
SUBGRADE PREPARATION FOR BULK EARTHWORKS. ALL UNSUITABLE BATTERS UP TO 3M IN HEIGHT. DEEPER CUTS ARE TO BE ASSESSED BY
2. ALL SETOUT ON SITE IS THE SOLE RESPONSIBILITY OF THE 20. CONTRACTOR TO PREPARE AND HAVE APPROVED BY RELEVANT MATERIAL TO BE REMOVED FROM SITE AT CONTRACTORS EXPENSE. THE GEOTECHNICAL ENGINEER.
CONTRACTOR. CONTRACTOR TO ALLOW FOR ALL MEANS NECESSARY AUTHORITY: ROAD OPENING PERMIT AND TRAFFIC MANAGEMENT PLAN
TO ACCURATELY SETOUT THE WORKS. FOR ALL WORKS WITHIN COUNCIL ROAD RESERVES. CONTRACTOR TO 4. COMPACTION OF THE EXPOSED SAND SUBGRADE REQUIRES 21. WHERE THE ABOVE TEMPORARY BATTER SLOPES CAN NOT BE
ALLOW FOR ALL COSTS ASSOCIATED WITH IMPLEMENTATION OF THE SUBSTANTIAL VOLUMES OF WATER COMBINED WITH VIBRATORY ACHIEVED, TEMPORARY SHORING WILL BE REQUIRED UNDER THE
3. ALL WORKS TO BE CONSTRUCTED IN ACCORDANCE WITH PROJECT TMP. COMPACTION EQUIPMENT. CARE MUST BE TAKEN TO ENSURE THERE ADVICE OF A SPECIALIST SHORING CONTRACTOR.
SPECIFICATIONS AND WHERE FURTHER DETAILS ARE REQUIRED THE ARE NO IMPACTS ON SURROUNDING STRUCTURES. MATERIAL TO BE
CONTRACTOR SHALL REFER TO NOOSA SHIRE COUNCIL DEVELOPMENT 21. ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH ALL LOCAL COMPACTED IN ACCORDANCE WITH GEOTECHNICAL REPORT AND 22. EXCAVATIONS IN PROXIMITY TO EXISTING STRUCTURES WILL REQUIRE
GUIDELINES, LOCAL WATER AUTHORITY GUIDELINES, ASSOCIATED AUTHORITY APPROVALS RECEIVED FOR THE PROJECT AND IN AS1289. SPECIFIC DESIGN TO PREVENT UNDERMINING WHICH SHOULD BE
STANDARD DRAWINGS AND SPECIFICATIONS U.N.O. ACCORDANCE WITH OPW APPROVALS BY COUNCIL. CARRIED OUT BY A SUITABLY QUALIFIED AND EXPERIENCED RPEQ
5. A MINIMUM 150MM THICK GRANULAR WORKING PLATFORM MAY BE STRUCTURAL ENGINEER.
4. SHOULD ANY OF THE CONSTRUCTED WORKS BE CONSTRUCTED 22. NO WORKS ARE TO BE UNDERTAKEN ON LAND OUTSIDE OF THE SITE REQUIRED ON SOIL SUBGRADES ALONG HAUL ROADS AND LAYDOWN
OUTSIDE OF THE TOLERANCES SPECIFIED WITHIN THE PROJECT BOUNDARY WITHOUT FORMAL APPROVAL BY THE OWNER/CUSTODIAN AREAS TO IMPROVE TRAFFICABILITY. SPECIFIC PLATFORM DESIGN 23. CONTRACTOR'S RPEQ GEOTECHNICAL ENGINEER IS TO CONFIRM THAT
SPECIFICATION AND LOCAL AUTHORITY REQUIREMENTS, THE OF THAT LAND INCLUDING BUT NOT LIMITED TO PRIVATE PROPERTY, WOULD BE REQUIRED PRIOR TO MOBILISATION AND TRAFFICKING OF ANY CONSTRUCTED CUT/FILL BATTERS AND RETAINING STRUCTURES
CONTRACTOR WILL RECTIFY AT THEIR COST INCLUSIVE OF ANY ROAD RESERVE, PARKS/OPENSPACE, EASEMENTS. ANY HEAVY MOBILE PLANT ON THE SITE. ON THE SITE HAVE ACHIEVED ADEQUATE STABILITY WITH A LONG-TERM
ADDITIONAL COSTS INCURRED BY RECOR. FACTOR OF SAFETY AGAINST GEOTECHNICAL FAILURES TO THEIR
23. THE CONTRACTOR SHALL HAVE AN APPROVED SET OF CONSTRUCTION 6. IMPORTED GENERAL FILL MATERIAL SHALL BE SUPPLIED AND SATISFACTION.
5. EXISTING SERVICES HAVE BEEN PLOTTED FROM SUPPLIED DATA AND DRAWINGS AND APPROVALS ON SITE AT ALL TIMES. COMPACTED WHERE UNSUITABLE NATURAL MATERIALS ARE LOCATED
AS SUCH THEIR ACCURACY CANNOT BE GUARANTEED. NO AND AS OTHERWISE NECESSARY TO OBTAIN SUBGRADE/PLATFORM 24. EARTHWORKS LEVELS SHOWN ARE FINISHED SURFACE LEVELS
RESPONSIBILITY IS TAKEN BY RECOR OR THE PRINCIPAL FOR THE LEVEL. IMPORTED GENERAL FILL MATERIAL SHALL BE CLEAN GRADED INCLUSIVE OF TOPSOIL LAYER. REFER TO STRUCTURAL ENGINEERING
24. ALL WATER AND SEWER RETICULATION WORKS TO BE CONSTRUCTED IN
ACCURACY AND COMPLETENESS OF THIS INFORMATION. IT IS THE MATERIAL FREE OF ORGANIC MATTER AND STONES, WITH MAXIMUM DRAWINGS FOR BUILDING SLAB THICKNESSES AND HYDRAULIC
ACCORDANCE WITH THE SEQ WATER SUPPLY AND SEWERAGE DESIGN
RESPONSIBILITY OF THE CONTRACTOR TO ACCURATELY ESTABLISH PARTICLE SIZE OF 100MM AND CAPABLE OF BEING COMPACTED INTO DRAWINGS FOR SUB-FLOOR DRAINAGE FOR DETERMINATION OF
AND CONSTRUCTION CODE (2013).
THE LOCATION AND LEVEL OF ALL EXISTING SERVICES PRIOR THE COHERENT FILLING TO THE SPECIFIED STANDARD. THE MATERIAL REQUIRED BULK EARTHWORKS SURFACE.
COMMENCEMENT OF ANY WORKS. ANY DISCREPANCIES SHALL BE SHALL HAVE A MAXIMUM PLASTICITY INDEX OF 15%, A SHRINK-SWELL
REPORTED TO THE SUPERINTENDENT. CONTRACTOR TO LOCATE AND STANDARD SIGNS AND LINE MARKING NOTES INDEX OF LESS THAN OR EQUAL TO 1% AND A MINIMUM C.B.R. OF 10%. 25. ANY PRELOADING REQUIRED IS TO OCCUR IN ACCORDANCE WITH THE
PROTECT SERVICES AS REQUIRED DURING PROPOSED WORKS. 1. GENERAL GEOTECHNICAL ENGINEERS REQUIREMENTS. CONTRACTOR TO ALLOW
a. ALL SIGNS AND PAVEMENT MARKING IS TO BE IN ACCORDANCE WITH 7. ALL EARTHWORKS TO BE CARRIED OUT AT +/- 2% OPTIMUM MOISTURE FOR THE IMPORT AND REMOVAL OF ALL NECESSARY MATERIAL TO
6. THE CONTRACTOR IS TO CHECK THROUGH LOCATING, POTHOLING AND THE QUEENSLAND TRANSPORT MANUAL OF UNIFORM TRAFFIC CONTENT FOR STANDARD COMPACTION. UNDERTAKE THE PRELOADING OPERATIONS.
SURVEY ALL CRITICAL CONNECTION POINTS FOR ALL CIVIL WORKS CONTROL DEVICES (CURRENT EDITION).
SHOWN ON THE DRAWINGS INCLUDING ANY POTENTIAL EXISTING 8. ANY PROPOSED RETAINING WALL WORKS MUST BE WHOLLY WITHIN THE
2. SIGNS 26. REFER ARCHITECTURAL DRAWINGS FOR BUILDING SETOUT.
SERVICES CLASHES PRIOR TO COMMENCEMENT OF CIVIL WORKS. PROPERTY BOUNDARY OF THE SUBJECT SITE, INCLUDING REAR OF
a. ALL SIGNS TO BE REFLECTORISED CLASS 1 TO AS1906.1:2007 UNLESS
CONTRACTOR TO IMMEDIATELY REPORT ANY DISCREPANCIES TO RETAINING WALL DRAINAGE INFRASTRUCTURE FOR RETAINING WALLS
RECOR AND AWAIT FORMAL DIRECTION PRIOR TO COMMENCING CIVIL NOTED OTHERWISE.
IN CUT. RETAINING WALLS ARE TO BE PREPARED IN ACCORDANCE WITH
WORKS. b. SIGNS ARE TO BE INSTALLED WITH THE FOLLOWING CLEARANCES TO STRUCTURAL ENGINEERS SPECIFICATIONS, AND IN CONFORMANCE INSPECTIONS:
EDGE OF SIGN: LOCATION CLEARANCE NO KERB 600 BEHIND GUIDE WITH CONSTRUCTION REQUIREMENTS OF GEOTECHNICAL REPORT. THE FOLLOWING INSPECTIONS MUST BE COMPLETED BY RECOR ENGINEERS
7. ON COMPLETION OF SERVICES INSTALLATION, ALL DISTURBED AREAS POSTS BARRIER KERB 300 FROM FACE MOUNTABLE KERB 500 FROM BEFORE ENGINEERING CERTIFICATION WILL BE ISSUED. THE CONTRACTOR
SHALL BE RESTORED TO ORIGINAL LEVEL, INCLUDING KERBS, FACE OF KERB. 9. REFER ARCHITECT/LANDSCAPE ARCHITECT DRAWINGS FOR IS TO PROVIDE A MINIMUM OF 72 HOURS NOTICE TO RECOR FOR REQUIRED
FOOTPATHS, CONCRETE AREAS, GRAVEL AREAS, GRASSED AREAS AND CONFIRMATION OF RETAINING WALL COLOUR AND FINISH. INSPECTIONS. SHOULD THE CONTRACTOR FAIL TO REQUEST AN
ROAD PAVEMENTS. c. PARKING CONTROL SIGNS TO BE MOUNTED TO FACE APPROACHING
INSPECTION, THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL COSTS TO
TRAFFIC AT 45° TO KERB OR CARRIAGEWAY EDGE. ALL OTHER SIGNS TO ALLOW FOR THE WORKS TO BE INSPECTED TO THE SATISFACTION OF
10. ALL EARTHWORKS OPERATIONS SHALL BE CARRIED OUT WITH 'LEVEL 2'
8. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO BE TURNED AWAY BY 5° FROM THE NORMAL TO APPROACHING RECOR. ANY INSPECTIONS THAT FAIL ARE TO BE RE-INSPECTED WITH ALL
SOIL ENGINEERING SUPERVISION IN ACCORDANCE WITH APPENDIX B OF
AUTHORITY/COUNCIL'S INFRASTRUCTURE. SUCH REPAIR OR HEADLIGHT. AS 3798. THE NOMINATED GEOTECHNICAL TESTING AUTHORITY SHALL REINSPECTION COSTS TO BE PAID BY THE CONTRACTOR.
REINSTATEMENT TO BE CARRIED OUT IMMEDIATELY TO THE 3. SIGN SUPPORTS PROVIDE CERTIFICATION THAT ALL GENERAL EARTHWORKS
SATISFACTION OF INFRASTRUCTURE OWNER/MANAGER / a. SLEEVED SIGNS SUPPORTS ARE TO BE PROVIDED IN ALL AREAS OPERATIONS HAVE BEEN CARRIED OUT IN ACCORDANCE WITH THE a. PRESTART
AUTHORITY/COUNCIL. WHERE THEY ARE IN A PAVED SURFACE. DRAWINGS AND SPECIFICATIONS AND THE CONTROLLED FILL IS
4. LINEMARKING SUITABLE FOR PURPOSE TO THE REQUIRED BEARING CAPACITY UNDER b. EARTHWORKS - FINAL STRIPPING OF TOPSOIL, INSTALLATION OF
9. CONTRACTOR TO UNDERTAKE ALL WORKS IN ACCORDANCE WITH ALL a. REDUNDANT LINEMARKING IS TO BE GROUND OFF. THE PLATFORM/STRUCTURES AS SPECIFIED BY THE GEOTECHNICAL SEDIMENT AND EROSION CONTROL MEASURES UNSUITABLE GROUND
WORKPLACE HEALTH AND SAFETY REQUIREMENTS. REPORT.
b. THERMOPLASTIC LINEMARKING TO BE USED FOR ALL CONCRETE.
c. SIDE AND CUT OFF DRAINS
10. WHERE ANY EXCAVATION OR CONSTRUCTION WORKS ARE TO BE IN 11. ALL EARTHWORKS FILL AND EXCAVATED AREAS SHALL BE COMPACTED
CLOSE PROXIMITY TO NEIGHBOURING LOT BOUNDARIES OR JOINTING NOTES TO 98% STANDARD MAXIMUM DRY DENSITY OR A DRY DENSITY INDEX
INFRASTRUCTURE, CONTRACTOR TO ALLOW IN SCOPE OF WORKS TO OF AT LEAST 75% IN ACCORDANCE WITH THE GEOTECHNICAL REPORT d. STORMWATER PIPE LAID ON BEDDING PRIOR TO BACKFILL
PROVIDE ALL MEASURES NECESSARY TO ENSURE THE INTEGRITY OF 1. ALL JOINTING AND CONCRETE TO BE IN ACCORDANCE WITH THE IN LAYERS OF 250MM LOOSE THICKNESS (PRIOR TO COMPACTION).
EXISTING BOUNDARIES AND INFRASTRUCTURE. THIS MAY INCLUDE THE REQUIREMENTS OF AS3727.1:2016.
e. STORMWATER TRENCH BACKFILLED PRIOR TO PAVEMENT PLACEMENT
USE OF LOW VIBRATION EQUIPMENT, TRENCH SHORING ETC AS 2. SAW CUT JOINTS MUST BE:
12. COMPACTION TESTING TO BE CARRIED OUT AT A MINIMUM OF TWO
REQUIRED. a. BETWEEN 1 AND 1 OF CONCRETE PAVEMENT DEPTHS. TESTS PER VERTICAL LIFT WHERE STRUCTURAL FILL HEIGHTS EXCEED
4 3 300MM IN ACCORDANCE WITH AS3798. CONTRACTOR TO UNDERTAKE
f. STORMWATER STRUCTURE BASE SLABS
11. PRIOR TO THE CONTRACTOR COMMENCING ANY WORKS DETAILED ON b. CLEARED OF ANY DEBRIS FROM THE CUTTING METHOD. ALL EARTHWORKS TESTING IN ACCORDANCE WITH GEOTECHNICAL
THESE DRAWINGS, THE CONTRACTOR IS TO NOTIFY RECOR AND ENGINEER AND LOCAL AUTHORITY REQUIREMENTS. g. PAVEMENT SUBGRADE
c. PERFORMED WITHIN 6 TO 12 HOURS OF FINISHING CONCRETE POURS.
RECEIVE WRITTEN CONFIRMATION THAT WORKS CAN COMMENCE.
3. DOWELL BARS MUST BE INSTALLED EXACTLY 90° TO THE FACE OF JOINT
13. FINISHED SURFACES TO ALL DISTURBED AREAS ARE TO BE TREATED IN h. PAVEMENT REINFORCING
12. CONTRACTOR TO PROVIDE AS CONSTRUCTED DRAWINGS FOR ALL TO ALLOW EXPANSION AND CONTRACTION MOVEMENTS.
ACCORDANCE WITH LANDSCAPE DRAWINGS.
CONSTRUCTED WORKS IN ACCORDANCE WITH LOCAL GOVERNMENT 4. JOINTING LAYOUT TO BE CONFIRMED BY SUPERINTENDANT PRIOR TO
CONSTRUCTION COMMENCING. LAYOUT SHOULD AVOID ACUTE ANGLES i. PAVEMENT PRIOR TO SEALING (PRESEAL)
REQUIREMENTS. UNLESS OTHERWISE ADVISED BY RECOR 14. ALL NEW WORKS TO MATCH NEATLY INTO EXISTING LEVELS.
CONTRACTOR TO NOTE COUNCILS ADAC REQUIREMENTS. IN THE CONCRETE SLAB AND AVOID MISMATCHED JOINTS.
5. JOINT SEALANTS WHERE USED MUST ADHERE TO SIDE OF JOINT FACES j. RETAINING WALL FOOTING REINFORCING
ONLY AND SHALL NOT EXTEND ABOVE SIDES OF JOINTS ONTO THE SLAB 15. ALL WORKS TO BE CONSTRUCTED IN ACCORDANCE WITH APPROVED
13. CONTRACTOR TO UNDERTAKE ALL WORKS IN ACCORDANCE WITH
SURFACE. MANAGEMENT PLANS.
RELEVANT APPROVALS. k. RETAINING WALL BLOCKWORK PRIOR TO CORE FILL
6. DOWEL BARS ARE TO BE
a. FOR 100MM THICK SLAB, 12MM Ø OF LENGTH 300MM AND SPACED AT 16. CONTRACTOR TO ENSURE SUITABLE EROSION CONTROL MEASURES
14. CONTRACTOR TO ALLOW TO LIASE/CO-ORDINATE WITH ELECTRICAL,
400MM CENTRES ARE INSTALLED INCLUDING BUT NOT LIMITED TO SHAKE DOWNS, SILT l. STEEL REINFORCEMENT OF CONCRETE STRUCTURES
LANDSCAPE AND OTHER SERVICE CONTRACTORS THROUGHOUT CIVIL
b. FOR 125MM THICK SLAB, 16MM Ø OF LENGTH 350MM AND SPACED AT FENCE ETC IN ACCORDANCE WITH EROSION AND SEDIMENT CONTROL
CONSTRUCTION.
PLAN m. PRACTICAL COMPLETION
300MM CENTRES
15. CONTRACTOR TO ORGANISE ALL DEMOLITION PERMITS PRIOR c. FOR 150MM THICK SLAB, 20MM Ø OF LENGTH 400MM AND SPACED AT
17. ADEQUATE SAFETY FENCING/BARRIERS TO BE APPLIED TO ALL
DEMOLITION WORKS COMMENCING ON SITE. 300MM CENTRES n. ON MAINTENANCE
BATTERS OR RETAINING WALLS (TEMPORARY OR PERMANENT) AS PER
RELEVANT AUSTRALIAN STANDARDS AND LEGISLATION.
16. CONTRACTOR TO ALLOW TO DEMOLISH ALL EXISTING STRUCTURES, o. OFF MAINTENANCE
ROADS AND SERVICES WITHIN LIMIT OF WORKS AND REMOVE FROM EARTHWORKS NOTES 18. DUST CONTROL MEASURES ARE TO INCLUDE SPRAYING WATER ON
SITE U.N.O.
1. FOR DETAILED GEOTECHNICAL INFORMATION, REFER GEOTECHNICAL UNPAVED ROADS, ACCESS TRACKS AND STOCKPILES AT A SUFFICIENT p. ANY OTHER INSPECTION AS SPECIFIED BY LOCAL COUNCIL (REFER
INVESTIGATION REPORT BY GEOTECHNICAL ENGINEER. IT IS LEVEL TO SUPPRESS DUST GENERATION. ADDITIONALLY CONTRACTORS DEVELOPMENT APPROVAL)
17. CONTRACTOR TO UNDERTAKE DILAPIDATION REPORT FOR ADJOINING ARE TO COVER OR ENCLOSE STOCKPILES WHERE REASONABLY
RECOMMENDED THAT THE GEOTECHNICAL CONSULTANT BE
PROPERTIES AND COUNCIL ROADS AND VERGES PRIOR TO PRACTICAL TO RESTRICT DUST MOVEMENT.
CONTACTED TO CONFIRM THE SOIL CONDITIONS PRIOR TO
COMMENCEMENT OF ANY WORKS ON SITE.
EARTHWORKS COMMENCING.
19. PRIOR TO THE CONTRACTOR COMMENCING ANY WORKS DETAILED ON
18. CONTRACTOR TO CLEAR AND GRUB ALL VEGETATION ON SITE AS THIS DRAWING, THE CONTRACTOR IS TO NOTIFY RECOR AND RECEIVE
2. GRASS AND TOPSOIL SHALL BE STRIPPED TO A MINIMUM DEPTH OF
IDENTIFIED IN THE APPROVED VEGETATION MANAGEMENT PLAN. WRITTEN CONFIRMATION THAT WORKS CAN COMMENCE.
100MM OVER THE EXTENT OF THE WORKS UNLESS DIRECTED
CONTRACTOR TO ENSURE ALL TREE ROOTS AND STUMPS ARE
OTHERWISE AND STOCKPILED WHERE REQUIRED FOR FILL OF
COMPLETELY REMOVED AND BACKFILLED TO LEVEL 1 SUPERVISION.
LANDSCAPING AREAS. TOPSOIL MATERIALS MUST NOT BE USED IN 20. ALL EXCAVATIONS ARE TO BE CONDUCTED IN ACCORDANCE WITH THE
CONTRACTOR TO ALLOW TO MULCH ALL CLEARED VEGETATION
ENERGY SERVICE PROVIDERS TELECOMMUNICATIONS
SERVICE PROVIDERS elstra Manual of Uniform Traffic Control Devices
BEFORE YOU DIG SERVICE LOCATIONS AGL AUSTRALIA
ERGON. 60
ENERGY
energex ' yes' Telstra
WARNING: OPTIC FIBRE
IT IS THE RESPONSIBILITY OF THE PRINCIPAL visionstream km/h
CONTRACTOR TO CONTACT ALL RELEVANT origin OPTUS
SERVICE AUTHORITIES TO VERIFY THE NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM EXTREME CARE TO BE TAKEN WHILE EXCAVATING IN THE
NOTE: ALL SIGNS & LINE MARKING TO BE IN
LOCATION OF ALL EXISTING SERVICES PRIOR PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED VICINITY OF OPTIC FIBRE CABLES. LOCATIONS ARE TO ACCORDANCE WITH THE MANUAL OF
PRIOR TO START OF CONSTRUCTION. PHONE DBYD PRIOR TO START OF CONSTRUCTION. PHONE DBYD
TO THE START OF CONSTRUCTION SERVICE LOCATIONS ON 1100 FOR DETAILS. SERVICE LOCATIONS ON 1100 FOR DETAILS.
BE CONFIRMED PRIOR TO START OF CONSTRUCTION. UNIFORM TRAFFIC CONTROL DEVICES.
North Point Approved Project Address Title
206 DAVID LOW WAY GENERAL NOTES
PEREGIAN BEACH QLD 4573
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 17.10.23 ISSUE FOR OPW QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
002 C
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK the revision description.
Section 3
Commedunfr
Plott
ow
21.09 21.07 21.33
i nd37m
W
p 20.
18.9
EXISTING TELSTRA
o
T RL
ications
17.99
om recordsWater Reticm
Top Window
RL 20.34m
NOTES:
EXISTING SEWER 1. FOR GENERAL NOTES REFER DWG 002, WHICH IS TO BE REQUESTED AND
SewehrolePlonot found
Man
Top Window
Plotted fro
RL 20.34m VIEWED PRIOR TO COMMENCEMENT OF CONSTRUCTION IF NOT SUPPLIED.
WateredRefrtiocm records
Plott
19.21 19.19
21.07 22.3 2. THE CONTRACTOR WILL MAKE HIMSELF FULLY AWARE OF THE EXISTING
tted From
21.06
FEATURES OF THIS SITE AND ENSURE ANY ADDITIONAL WORKS NOT
T
W
ulatiocnords Edge//o/f/ Bitum ////
SHOWN ON THIS PLAN ARE INCLUDED IN THE CONTRACT.
re
Water
ulation
Meter 18.33 18.32 18.32 18.18
3. LOCATION AND DEPTH OF EXISTING SERVICES BASED ON SURVEY, DBYD
S
Records
55
Yard RL 15.0m AND COUNCIL RECORDS. IT IS THE CONTRACTORS RESPONSIBILITY TO
WM EXISTING SEWER P9319
CONFIRM ACTUAL LOCATION AND DEPTH PRIOR TO CARRYING OUT ANY
Edge of B
Driveway
MANHOLE 18.04
////
W
RL 15.1m EXCAVATION OR TRENCHING WORKS.
PP
90°0' 18.1
T
18.1
W
/ / / 4. CONTRACTOR TO LOCATE AND PROTECT ALL EXISTING SERVICES ON SITE
itumen
PP 25.293 PRIOR TO COMMENCEMENT OF WORKS.
EXISTING OVERHEAD
en
15.98m
15.71m
////
ELECTRICITY 16.2
DAVID L
19.22 5. CONTRACTOR TO ORGANISE ALL DEMOLITION PERMITS PRIOR TO ANY
DEMOLITION WORKS COMMENCING ON SITE.
/
16.4
W
OE
6. ALL VEGETATION WITHIN THE LIMIT OF WORKS TO BE CLEARED, MULCHED
OE
////
OW
////
AND REMOVED FROM SITE IN ACCORDANCE WITH APPROVED VEGETATION
T
16.6
W
CLEARING PLAN (BY OTHERS) OR IF SCHEDULED STOCKPILE FOR USE BY
WAY
OE
LANDSCAPER.
EXISTING WATER Garden
16.8 RL 15.75m
////
////
7. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES ON SITE AND MAKE
SUITABLE ARRANGEMENTS TO HAVE DISCONNECTED PRIOR TO
OE
Garden DEMOLITION WORKS BEGINNING.
W
17.0 RL 16.5m
OET
8. PRIOR TO THE CONTRACTOR COMMENCING ANY WORKS DETAILED ON
////
////
W
Ov
17.2 THIS DRAWING, THE CONTRACTOR IS TO NOTIFY RECOR AND RECEIVE
er
EXISTING EDGE 21
hea
19.21 19.2
OF BITUMEN WRITTEN CONFIRMATION THAT WORKS CAN COMMENCE.
P9313
d
17.4
Ele
/
Conc Slab RL 17.46m 9. CONTRACTOR TO UNDERTAKE DILAPIDATION REPORT FOR ADJOINING
ctr
////
////
icit
PROPERTIES AND COUNCIL ROADS AND VERGES PRIOR TO
y
W
COMMENCEMENT OF ANY WORKS ON SITE.
OE
OE
10. CONTRACTOR TO ALLOW TO DEMOLISH ALL EXISTING STRUCTURES,
/
T
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \
W
////
OE
////
ROADS AND SERVICES WITHIN LIMIT OF WORKS AND REMOVE FROM SITE
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \
Bench Mark 54 U.N.O.
EXISTING DRIVEWAY
Nail in Bitumen P9319 21.98
182°13'20"
CROSSOVER TO BE RL 16.78m Pool Area
22.128
REMOVED Carport Eave RL 17.25m 11. WHERE NECESSARY, CONTRACTOR SHALL OBTAIN ALL NECESSARY
/
RL 19.5m
22.303
352°30'
Top Window
Roof Peak RL 24.2m APPROVALS TO CARRY OUT SERVICES RELOCATION OR ALTERATIONS.
RL 21.36m
////
////
W
First Floor
RL 20.13m
T
Ground Floor
W
OE ////
OE
RL 17.49m
519 sq.m
////
23.63
Concrete CP
Driveway SP204267
17.58m
23.55 23.64
Top Window
W
RL 21.59m
////
////
/
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \
LEGEND:
\ \
T
W
OE
OE
23.63
23.53 ADJACENT BOUNDARY
////
////
Concrete Path
23.64
EXISTING MINOR CONTOUR
Water
W
Meter 17.0 EXISTING MAJOR CONTOUR (INTERVAL 0.2m)
Top Window
EXISTING BUILDING, STRUCTURES
RL 21.3m
AND IMPERVIOUS SURFACES TO
////
////
WM BE REMOVED U.N.O EXISTING MINOR CONTOUR (INTERVAL 0.1m)
T
W
FH 18.0m 18.4 21.525
18.13m
/ / EXISTING FENCE
Comms 270°0' 22.0
Pit WM \ \ \ \ \ \ \ \ \ \ \ EXISTING BUILDING
////
////
Water
Meter
OE
OE EXISTING OVERHEAD ELECTRICITY
OE
21.91
W
21.9
Top Wall RL 22.7m
26.46 SW EXISTING STORMWATER
T
W
////
51
////
W EXSTING WATER
WateredRefrtiocm records
Plott
26.47
P9319
Top Wall RL 22.87m
21.87
26.46
FH S EXISTING SEWER
T EXISTING TELSTRA
////
ulation
////
OE
21.9
OE
EXISTING TELSTRA PIT
FH
EXISTING WATER FIRE HYDRANT
Bench Mark
////
////
Nail in Bitumen WM
RL 17.86m EXISTING WATER METER
EXISTING SEWER MANHOLE
EXISTING TREE
OE
OE
1 0 1 2 3 4 5
OE
OE
SCALE (metres)
1 : 100 (FULL SIZE)
North Point Approved Project Address Title
206 DAVID LOW WAY EXISTING LAYOUT PLAN
N
PEREGIAN BEACH QLD 4573
OE
OE
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 17.10.23 ISSUE FOR OPW QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
003 B
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check the revision description.
OE
DO NOT SCALE, IF IN DOUBT ASK
OE
Section 4
T
W
S
55
WM P9319
////
W
////
PROPOSED PP
GROUTED ROCK
T
W
SCOUR PROTECTION
PP
////
////
DAVID L
W
OE
////
OW
////
T
W
WAY
OE
////
////
W
OET
////
////
W
21
P9313
NOTE:
////
////
EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN DRAWINGS,
W
ALL IN-GROUND SERVICES WITHIN THE PROPERTY BOUNDARY INCLUDING
OE
OE
BUT NOT LIMITED TO: STORMWATER DRAINAGE, SEWERAGE, WATER, GAS,
T
W
PROPOSED 18kL ELECTRICAL AND COMMUNICATIONS TO BE SAFELY BE DISCONNECTED,
////
////
CONCRETE WATER TANK REMOVED FROM SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR
TO ARRANGE ALL NECESSARY APPLICATIONS AND PERMITS WITH THE
RELEVANT AUTHORITIES. SERVICES TO BE CAPPED IN ACCORDANCE WITH
PROPOSED 5.5m WIDE VEHICLE
RELEVANT SERVICE PROVIDER SPECIFICATIONS AND STANDARD DETAILS
////
CROSSOVER IN ACCORDANCE
////
W
WITH IPWEA STD DRG RS 049 AND
RS 050 LEGEND:
T
W
OE ////
OE
////
ADJACENT BOUNDARY
CP
SP204267 PROPOSED BOUNDARY
EXISTING FENCE
W
////
////
\ \ \ \ \ \ \ \ \ \ \ EXISTING BUILDING
T
W
OE
OE
OE EXISTING OVERHEAD ELECTRICITY
////
////
SW EXISTING STORMWATER
W EXSTING WATER
W
S EXISTING SEWER
////
////
WM
T
PROPOSED 600 WIDE
W
DISH DRAIN FH T EXISTING TELSTRA
EXISTING TELSTRA PIT
WM
////
FH
////
EXISTING WATER FIRE HYDRANT
OE
WOE
WM
EXISTING WATER METER
T
W
////
51 EXISTING SEWER MANHOLE
////
MATCH NEATLY TO P9319
EXISTING SURFACE EXISTING TREE
FH
PROPOSED RETAINING WALL
////
////
OE
OE
PROPOSED STORMWATER PIPE
PROPOSED CONCRETE PAVEMENT
////
////
PROPOSED CONCRETE SPOON DRAIN
PROPOSED GROUTED ROCK SCOUR PROTECTION
OE
OE
1 0 1 2 3 4 5
OE
OE
SCALE (metres)
1 : 100 (FULL SIZE)
North Point Approved Project Address Title
206 DAVID LOW WAY OVERALL LAYOUT PLAN
N
PEREGIAN BEACH QLD 4573
OE
OE
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 31.03.23 OPW ISSUE QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
010 C
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check the revision description.
OE
DO NOT SCALE, IF IN DOUBT ASK
OE
Section 5
CUT/FILL DEPTH RANGE CUT/FILL DEPTH RANGE
LOWER VALUE UPPER VALUE COLOUR LOWER VALUE UPPER VALUE COLOUR
-2.20 TO -2.10 m -0.20 TO -0.10 m
-2.10 TO -2.00 m -0.10 TO 0.00 m
-2.00 TO -1.90 m 0.00 TO 0.10 m
-1.90 TO -1.80 m 0.10 TO 0.20 m
-1.80 TO -1.70 m 0.20 TO 0.30 m
-1.70 TO -1.60 m 0.30 TO 0.40 m
-1.60 TO -1.50 m 0.40 TO 0.50 m
-1.50 TO -1.40 m 0.50 TO 0.60 m
-1.40 TO -1.30 m 0.60 TO 0.70 m
-1.30 TO -1.20 m 0.70 TO 0.80 m
C
-1.20 TO -1.10 m 0.80 TO 0.90 m
C21
-1.10 TO -1.00 m 0.90 TO 1.00 m
T
W
-1.00 TO -0.90 m 1.00 TO 1.10 m
-0.90 TO -0.80 m 1.10 TO 1.20 m
S
TOW 17.88 TOW 16.09 TOW 16.10 TOW 17.53 TOW 17.53 -0.80 TO -0.70 m 1.20 TO 1.30 m
WM BOW 15.92 BOW 15.54 BOW 16.20 BOW 16.20
BOW 16.59 -0.70 TO -0.60 m 1.30 TO 1.40 m
////
W
////
H = 1.29m H = 0.17m H = 0.56m H = 1.33m H = 1.33m
PP -0.60 TO -0.50 m 1.40 TO 1.50 m
T
W
PP -0.50 TO -0.40 m 1.50 TO 1.60 m
15
.8
////
16.2
////
BATTER 1 IN 5 -0.40 TO -0.30 m
DAVID L
-0.30 TO -0.20 m
16.2
/
16.4
16
W
OE
.0
////
OW
////
T
16.6
W
WAY
16.4 EARTHWORKS VOLUMES
OE
EARTHWORKS VOLUMES FROM STRIPPER EXISTING SURFACE LEVEL
16.8
////
16.
////
(100mm OF TOPSOIL STRIPPING OF THE EXISTING SURFACE) TO BULK
2
EARTHWORKS SURFACE LEVELS.
OE
W
17.0 CUT = 68.05 m³
OET
FILL = 105.14 m³
////
////
W
BALANCE = 37.08 m³
17.2
CUT & FILL VOLUME NOTES
17.4 1. BULK EARTHWORKS LEVEL REPRESENTS
/
TOW 17.25 - 200mm BELOW DESIGN SURFACE LEVEL FOR BUILDING
////
////
BOW 16.50
- 225mm BELOW DESIGN SURFACE LEVEL FOR DRIVEWAY
H = 0.75m
W
2. BULK EARTHWORKS VOLUMES EXCLUDE A NOMINAL 100mm OF
TOW 17.40
TOPSOIL STRIPPING VOLUME WITHIN EARTHWORKS AREA
OE
OE
/ BOW 16.82
T
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \
W
H = 0.58m
////
OE
////
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \
.8
/
B
16
////
////
17.0
W
C21
LEGEND:
T
W
OE ////
OE
17.2
////
ADJACENT BOUNDARY
PROPOSED BOUNDARY
A
W
17.0 EXISTING MAJOR CONTOUR (INTERVAL 0.2m)
////
////
C21
/
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ EXISTING MINOR CONTOUR (INTERVAL 0.1m)
T
W
OE
OE
TOW 17.50
EXISTING FENCE
BOW 17.32
////
H = 0.18m
////
\ \ \ \ \ \ \ \ \ \ \ EXISTING BUILDING
OE EXISTING OVERHEAD ELECTRICITY
W
SW EXISTING STORMWATER
18.2
////
////
WM
T
W
FH .4 W EXSTING WATER
18
18.4
/ /
S EXISTING SEWER
WM
////
////
T EXISTING TELSTRA
TOW 18.39 BATTER 1 IN 4
OE
TOW 18.08 TOW 18.00
WOE
BOW 17.45 BOW 17.90 BOW 17.90 EXISTING TELSTRA PIT
H = 0.63m H = 0.49m H = 0.1m
FH
T
W
////
EXISTING WATER FIRE HYDRANT
////
WM
EXISTING WATER METER
FH
EXISTING SEWER MANHOLE
////
////
OE
OE
EXISTING TREE
17.0 EARTHWORKS CONTOUR MAJOR (INTERVAL 0.2m)
////
////
EARTHWORKS CONTOUR MINOR (INTERVAL 0.1m)
PROPOSED RETAINING WALL
OE
OE
NOTE:
EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN DRAWINGS, ALL IN-GROUND SERVICES
WITHIN THE PROPERTY BOUNDARY INCLUDING BUT NOT LIMITED TO: STORMWATER DRAINAGE,
SEWERAGE, WATER, GAS, ELECTRICAL AND COMMUNICATIONS TO BE SAFELY BE DISCONNECTED,
REMOVED FROM SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR TO ARRANGE ALL
1 0 1 2 3 4 5
OE
NECESSARY APPLICATIONS AND PERMITS WITH THE RELEVANT AUTHORITIES. SERVICES TO BE CAPPED
OE
IN ACCORDANCE WITH RELEVANT SERVICE PROVIDER SPECIFICATIONS AND STANDARD DETAILS SCALE (metres)
1 : 100 (FULL SIZE)
North Point Approved Project Address Title
206 DAVID LOW WAY BULK EARTHWORKS LAYOUT PLAN
N
PEREGIAN BEACH QLD 4573
OE
OE
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 31.03.23 OPW ISSUE QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
020 C
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check the revision description.
OE
DO NOT SCALE, IF IN DOUBT ASK
OE
Section 6
UNIT 2
LOT BOUNDARY
DRIVEWAY GARARE BED LANDSCAPE
LOT BOUNDARY
DAVID LOW WAY CP
SP204267
DESIGN SURFACE
53 58
17. 17.
3.6%
5.4% 3.5%
5.0%
12.5%
17
0.20m
17 17 17
0.20m
.3 .3
.2 7
0.225m
17 .2 5 0 EXISTING SURFACE EARTHWORKS SURFACE
0
.0
2
MATCH NEATLY PROPOSED RETAINING WALL
EXISTING KERB H = 0.38m
A BULK EARTHWORKS
020 SECTION SCALE 1:50
UNIT 1
DRIVEWAY GARAGE BED LANDSCAPE
LOT BOUNDARY
LOT BOUNDARY
DAVID LOW WAY
CP
SP204267
DESIGN SURFACE
.53 .53
9 6.1% 17 17
10.1% 1 7.2
9
16
.0
14.5%
17
.9
7
12.5%
0
.7
0.20m
16
EXISTING SURFACE EARTHWORKS SURFACE
0.225m
PROPOSED RETAINING WALL
MATCH NEATLY H = 0.78m
EXISTING KERB
B BULK EARTHWORKS
020 SECTION SCALE 1:50
LOT BOUNDARY
LOT BOUNDARY
51
LANDSCAPE SWIMMING POOL STAIR UNIT 1 UNIT 2 PATH P9319
55
P9319
PROPOSED RETAINING WALL
H = 2.65m
18 .18 08 3.5
18. 1 IN
DESIGN SURFACE
53 53
17. 17.
0.20m
PROPOSED RETAINING WALL
0.20m
H = 0.55m
EXISTING SURFACE EARTHWORKS SURFACE
15.
53 C BULK EARTHWORKS
020 SECTION SCALE 1:50
PROPOSED RETAINING WALL PROPOSED RETAINING WALL
0.20m
H = 0.66m H = 2.64m
1.0 0 1.0 2.0
SCALE (metres)
1 : 50 (FULL SIZE)
North Point Approved Project Address Title
206 DAVID LOW WAY BULK EARTHWORKS SECTIONS
N
PEREGIAN BEACH QLD 4573
For and on behalf of RECOR Pty Ltd.
C 15.12.23 REISSUED FOR APPROVAL MP AB Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 17.10.23 RFI UPDATE HL BP www.recorconsulting.com | ABN 89 647 469 707 MADELEINE SWETE KELLY PROPOSED UNIT 20230023 A1
A 31.03.23 OPW ISSUE QT BP
AS SHOWN COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This DEVELOPMENT Drawing Number Revision
021 C
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK the revision description.
The text continues on section 7.