FOR CONTINUATION REFER TO C309

NOTES:

1. FOR OVERARCHING NOTES REFER C101 & C102 FOR DETAILS

LEGEND:

PROPOSED WHEELSTOP IN fl Y —ExE Exé
ACCORDANCE WITH AS2890 (Vn ‘

EXISTING UNDERGROUND ELECTRICITY

EXISTING SEWER MAIN

EXISTING WATERMAIN

EXISTING UNDERGROUND TELECOMMUNICATIONS
Ex.SWD EXISTING STORMWATER DRAINAGE

EXISTING TOE OF BATTER

EXISTING EDGE OF BITUMEN

EXISTING BUILDING
PL 16.120 e .
on . <¢ 3 . PROPOSED TOP OF BATTER
PROPOSED BUILDING

PROPOSED EDGE OF PAVEMENT

“LK : 0 FINISHED SURFACE CONTOUR
\ a oe S& % " (0.1m CONTOUR INTERVAL)

PROPOSED WHEELSTOP IN ACCORDANCE <>

WITH AS2890, REFER XXX FOR DETAILS. f

| Z|

|

ta

eh

PLA 82
rey

PROPOSED RETAINING WALL TBC

PL16.945¢

DENOTES PAVEMENT LEVEL

oe

S ~ 7
PLAT Fe 8
. -

SL16.945¢ DENOTES SURFACE LEVEL

of

PL16.4608%

\

HATCHING LEGEND

EXTENT OF CONCRETE PATHWAY, REFER
C101 & C102 FOR SPECIFICATIONS

EXTENT OF CONCRETE PAVEMENT,
REFER C101 & C102 FOR SPECIFICATIONS

EXTENT OF FLEXIBLE PAVEMENT ,
REFER C101 & C102 FOR SPECIFICATIONS

 

x

\ S
w \ s “

\ e we

\ .o"
Sh. ae | » x

ROPOSED PWD PARKING IN
—— ACCORDANCE WITH AS2890

 

 

 

ext

PL16.460—

(Vos
=

PL16.4608

 

FOR CONTINUATION REFER TO C312

 

NOOSA COUNCIL
APPROVED PLAN
OPW24/0125.01 29 JULY 2025

 

 

 

ALL EXISTING SERVICES LOCATED
WITHIN PROPOSED WORKS ARE
TO BE RELOCATED BY OTHERS

LEVEL DATUM

PSM 78213
LEVEL DATUM RL 21.597 AHD DERIVED

 

FIRE TRACK NOTE

FIRE ACCESS TRACK WORKS ARE NOT
PART OF THIS OPERATIONAL WORKS.

 

ATTENTION: FOR BEST RESULTS AND

ACCURATE UNDERSTANDING OF THESE

D AN DRAWINGS, PLEASE PRINT IN COLOUR.
PROPOSED

ACACIA BUILDING.
FFL 16.500

ALL EXISTING SERVICES LOCATED
WITHIN PROPOSED WORKS ARE
TO BE RELOCATED BY OTHERS

 

EXISTING SERVICES

ALL EXISTING SERVICES ARE TO BE
LOCATED BY THE CONTRACTOR PRIOR
TO COMMENCEMENT OF WORKS

 

EXISTING LEVELS
THE CONTRACTOR IS TO VERIFY ALL
LEVELS PRIOR TO COMMENCEMENT OF
WORKS. ANY DISCREPANCIES TO BE
: REPORTED TO THE SITE

~~ SUPERINTENDENT FOR DIRECTION
FOR CONTINUATION REFER TO C313

 

IN ASSOCIATION WITH

WOOLLAM CONSTRUCTIONS — -
Praek OZCARE NOOSA

Susanne AR Aso Date JUN 2024 “00 0 1 2 5_™_Wo5 number Trawing No Revision
80 COOYAR STREET, NOOSA HEADS S T P Teatbesso Reaeee TON | Checked MW | THSORAWNG is COPYRIGHT @ DO NOT STP24-0253 0311 1
CAIRNS WHITSUNDAYS SIZE. THIS DRAWING IS NOT TO BE USED FOR

22/01/2025
1 | FOR CONSTRUCTION ISSUE AS | MCW | 22.01.25
Rev Description By Appd Date

Appro ved MW CONSTRUCTION UNLESS THE APPROVED

FINISHED LEVELS PLAN - SHEET & Pe ets ;

CONSULTANTS

Drawing Title:
AMENDMENTS q

 

Document Set ID: 23476195
Version: 1, Version Date: 22/01/2025

C\Users\aaron\OC\ACCDocs \STP Consultants \STP24-0253 Ozcare Noosa\Project Files\STP-Civil\STP24-0253-RDP.dwg

Used in these records

About this file

File size
30.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plan - OPW24 0125.01 (As Published).pdf · 30.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.