Original source · versioned page text
6. Appendix C - Noosa Assessment Benchmark Assessment
Specific Outcomes Accepted Solutions Heading
Urban development reduces the including gardening, irrigation,
need for mains water by ponds and outdoor cleaning.
capturing and utilising run-off
from appropriate areas on site.
O3 S3.1 The proposal complies with the
Urban development reduces the Planting is in accordance with acceptable outcome because
need for mains water by PSP 3 Landscaping Plans and plants endemic to the local area
eliminating requirement for Guidelines. are proposed.
irrigation via the use the
endemic plant landscaping
design
O4 S4.1 The proposal complies with
Backflow devices or similar A suitable backflow prevention the acceptable outcome
systems are installed, where device is installed to protect the because backflow devices will
necessary, to ensure water drinking water within the be used if required.
reuse facilities have no impact reticulated water supply in
on the quality of the town mains accordance with AS/NZS
water. 3500:2003 Plumbing and
Drainage
Shire Business Centre No probable solution The proposal complies with the
performance outcome because
O5
all treatment devices are
Within the Shire Business Centre contained within the
site, as shown on Map SBC run- development area.
off treatment is contained within
the developable areas of the site
and drainage lines are only used
for final polishing of run-off; AND
O6 No probable solution The proposal complies with the
Within the Shire Business Centre performance outcome because
site, as shown on Map SBC, on- all detention devices are
site detention measures are contained within the
contained within the developable development area.
areas of the site, clear of
drainage lines and Open Space
Precincts.
Use of natural treatments and S7.1 The proposal complies with
systems No probable solution the performance outcome
O7 because gross pollutant traps
and treatment devices are
Natural treatment strategies, utilized. Bio-retention devices
including grass swales and bio- are not proposed due to
retention systems, vegetated limited space and
filtration strips and gross unfavorable topography.
pollutant traps, are used
wherever possible.
3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.