Original source · versioned page text
23110 Op Works Issue 20-12-2023
been treated for eradication of leaf hopper by systemic injection of an approved
insecticide to the Local Authority requirements and that the stock is not carrying
leaf hopper - Prior to installation
− Planting Maintenance Program for Superintendent’s approval and Logbook
recording when and what maintenance work has been done and what materials,
including toxic materials, have been used.
− Plant suppliers must be approved by the Superintendent prior to placing orders.
Submit to Superintendent details of proposed supplier(s) including industry
accreditation and third-party assessed QA system. Submit data on sources and
manufacturers of other components for Superintendent’s approval - Prior to
ordering.
Irrigation
− Scaled Design Drawings as specified for coordination and comment - Prior to
installation
− Letter of Certification confirming that design and details comply with this
specification and its Design Intent - Prior to installation
− All necessary local authority permits and approvals prior to installation. This
includes the supply and placement of backflow prevention devices, if required. -
Prior to installation
− Supply product literature, trouble-shooting and industry warrantees on the system
components. This operation manual shall take the form of a hard cover ring binder
- Prior to Practical Completion
− Supply written copy of typical Summer and Winter Irrigation programs - Prior to
Practical Completion
− Carry out a Training Program to ensure that maintenance staff can operate the
system - Prior end of Establishment/ Maintenance period.
6.2 "As Constructed" Drawings
1 x digital copy of each plan to be provided of the following drawings:
Irrigation Works
“As Constructed” Drawings of the irrigation works shall be submitted to the
Superintendent prior to Practical Completion.
“As Constructed” drawings shall include:
− All valve locations
− All pipe locations, sizes and depths
− All wiring and wiring joints
− Spray head locations
− Automatic controllers, rain switches
− All other valving
− Typical valve box assembly
− Irrigation pumps
Electrical services
− “As Constructed” Drawings of the electrical works shall be submitted to the
Superintendent prior to Practical Completion.
Path Network
Including constructed levels for walkways, paths, ramps and stairs
[email protected] David Low Way Duplex LANDSCAPE SPECIFICATION Project No. Drawing Issue NOT FOR CONSTRUCTION
23110 LA6-004 C
9 Fort Lane Issue Date Purpose Drawn Approved
Milton Qld 4064
206 David Low Way, Peregian Beach
A 11-10-2023 DRAFT ISSUE GG AG
PO Box 287
B 12-10-2023 OP WORKS ISSUE GG AG
Paddington Qld 4064
©2023 Wild Studio Australia Pty Ltd. These C 13-12-2023 OP WORKS ISSUE GG AG
urban landscape architecture drawings are protected by copyright and may not
wildstudio.com.au Client: Adam Offermann and Madeleine Swete Kelly be amended or reproduced without authorisation.