Skip to the record
For the highest quality transcripts.

Original source · versioned page text

Effluent Disposal Approval northern unit

of 16

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                  Advanced Enviro-septic Design Calculator V8.8 ©

                                                        Leader in Passive Solutions
                      Site
                              53 Martins Road Cooroy QLD 4563                                                                     State     QLD               Post Code                        4563
                    Address
                     Client
                              MAIN BED                                                                                                                    Date of Site Visit
                     Name
                                                                                                                                                           Designer Lic
                    Designers                                                                            Designers Ph
                              Chris Taylor | Director | Taylor Environmental (Aust)                                             Mb,0400 301 364               Number                15055672
                     Name                                                                                  Number
                      Lic                                                                                                                                   (eg.QBCC)
                                                                                                         Plumber Ph                                       Plumb / Drainer
                    Plumber TBA                                                                                                       TBA                                             TBA
                                                                                                           Number                                           Lic Number
                     Name
                    Council                                                                             Designers AES
                              Sunshine Coast                                                                                       QLD00011                     Date                 23/4/21
                      Area                                                                               Cert Number
                             This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

                                       System Designers site and soil calculation data entry                                                    IMPORTANT NOTES
                    Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary                     30         >> This design is for an ADVANCED SECONDARY system

                                                         Is this a new installation     Y or N                Y         >>     Minimun single vent size is 80mm or 2 x 50mm house vents

                                                                            Number of person                  4                a septic tank outlet filter is NOT RECOMMENDED

                                             Daily Design Flow Allowance Litre/Person/Day                    120

                                         Number of rows required to suit site constrants                      2         >>The maximum length of a single AES pipe run is 30 meters


                    Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY                    5         >> Catagory may require design considerations. Ref AS1547

                      Design Loading Rate based on site & soil evaluation DLR (mm/day)                       12         >> Soil conditioning may be necessary. Ref AS1547 & Comments.

                                                         Bore log depth below system Basel area              600        >>Min depth below basel area 600mm check water table/restrictive layer

                    Enter System footprint Slope in % for std AES systems to calc extension                   0

                              Is this design a gravity system with no outlet filter? Y or N                   y         >>     A House Vent & LOW VENT required on this system

                                PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES
                                                                                      40

                    COMMENTS :- " The outcome must be important to everyone. "
                    - Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.

                    - Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547




                    - Plumbers are reminded that good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions


                                                AES System Calculator Outcomes                                                                                AES dimensions

                                                          Total System load - litres / day (Q).              480        l/d                                AES System          System Extension

                                                Min Length of AES pipe rows to treat loading                 8.0        lm                  Lth m : (L)          9.6                   9.6

                                                    Number of FULL AES Pipe lengths per row                   3         lths              Width m:(W)            1.35                 2.82
                                                                                                                                             Sand
                                                 Total Capacity of AES System pipe in Litres                1272        ltr.                                     0.75                 0.15
                                                                                                                                            Depth :
                                        AES Additional infiltration extension required                      27.0        m2                    Area m2            13.0                 27.0
                               USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y)                              y

                                IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y"                                               Enter Custom Width in metre

                        AES INFILTRATION FOOT PRINT AREA -                   L = Q / ( DLR x W)           Length                 Width            Minimum AES foot print required .

                                                         for this Basic Serial design is                     9.6         x        4.17            =              40.0          m2 total




                      Code                        AES System Bill of Materials.                                                                       Chankar Environmental Use Only

                    AES-PIPE                         AES 3 mtr Lths required                                  6         lths                                                      Digitally signed by
                      AESC                          AESC Couplings required                                   4         ea                                                        Steve Dennis
                                                                                                                                                                                  DN: cn=Steve
                      AESO                            AESO Offset adaptors                                    4         ea
                                                                                                                                                                                  Dennis, o=Chandar
                    AESODV                           AES Oxgen demand vent                                    1         ea                                                        Enviromental,
                    AES-IPB                     AES 100mm Inspection point base                               2         ea
                                                                                                                                                                                  ou=Resign Review,
                                                                                                                                                  “Nature's Wastewater Solutions” email=designrevie

                    AES Equ                         AES Speed Flow Equaliser                                            ea                                                        w@enviro-
                    AES DESO                          Double Offset Adaptors                                            ea                                                        septic.com.au,
                                                                                                                                                                                  c=AU
                                     TOTAL SYSTEM SAND REQUIRED (Guide Only)                                 17         m3
                                                                                                                                                                                  Date: 2021.04.23
                                       PLEASE email your AES CALC and Drawings to                                                                                                 15:39:49 +10'00'
                                       [email protected]                                                                                  [email protected]
                    > The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil

                     conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer.

                    > Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.

                    > AES pipes can be cut to length on site. They are supplied in 3 meter lths only.

                                                                    AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty ltd 14/3/2016

Document Set ID: 21598877
Version: 1, Version Date: 30/08/2021
Log in to download the original file

Effluent Disposal Approval northern unit.pdf · 1.3 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.