Original source · versioned page text
Effluent Disposal Approval northern unit
Advanced Enviro-septic Design Calculator V8.8 ©
Leader in Passive Solutions
Site
53 Martins Road Cooroy QLD 4563 State QLD Post Code 4563
Address
Client
MAIN BED Date of Site Visit
Name
Designer Lic
Designers Designers Ph
Chris Taylor | Director | Taylor Environmental (Aust) Mb,0400 301 364 Number 15055672
Name Number
Lic (eg.QBCC)
Plumber Ph Plumb / Drainer
Plumber TBA TBA TBA
Number Lic Number
Name
Council Designers AES
Sunshine Coast QLD00011 Date 23/4/21
Area Cert Number
This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.
System Designers site and soil calculation data entry IMPORTANT NOTES
Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 >> This design is for an ADVANCED SECONDARY system
Is this a new installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of person 4 a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constrants 2 >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS1547
Design Loading Rate based on site & soil evaluation DLR (mm/day) 12 >> Soil conditioning may be necessary. Ref AS1547 & Comments.
Bore log depth below system Basel area 600 >>Min depth below basel area 600mm check water table/restrictive layer
Enter System footprint Slope in % for std AES systems to calc extension 0
Is this design a gravity system with no outlet filter? Y or N y >> A House Vent & LOW VENT required on this system
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES
40
COMMENTS :- " The outcome must be important to everyone. "
- Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Plumbers are reminded that good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions
AES System Calculator Outcomes AES dimensions
Total System load - litres / day (Q). 480 l/d AES System System Extension
Min Length of AES pipe rows to treat loading 8.0 lm Lth m : (L) 9.6 9.6
Number of FULL AES Pipe lengths per row 3 lths Width m:(W) 1.35 2.82
Sand
Total Capacity of AES System pipe in Litres 1272 ltr. 0.75 0.15
Depth :
AES Additional infiltration extension required 27.0 m2 Area m2 13.0 27.0
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) y
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre
AES INFILTRATION FOOT PRINT AREA - L = Q / ( DLR x W) Length Width Minimum AES foot print required .
for this Basic Serial design is 9.6 x 4.17 = 40.0 m2 total
Code AES System Bill of Materials. Chankar Environmental Use Only
AES-PIPE AES 3 mtr Lths required 6 lths Digitally signed by
AESC AESC Couplings required 4 ea Steve Dennis
DN: cn=Steve
AESO AESO Offset adaptors 4 ea
Dennis, o=Chandar
AESODV AES Oxgen demand vent 1 ea Enviromental,
AES-IPB AES 100mm Inspection point base 2 ea
ou=Resign Review,
“Nature's Wastewater Solutions” email=designrevie
AES Equ AES Speed Flow Equaliser ea w@enviro-
AES DESO Double Offset Adaptors ea septic.com.au,
c=AU
TOTAL SYSTEM SAND REQUIRED (Guide Only) 17 m3
Date: 2021.04.23
PLEASE email your AES CALC and Drawings to 15:39:49 +10'00'
[email protected] [email protected]
> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil
conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer.
> Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter lths only.
AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty ltd 14/3/2016
Document Set ID: 21598877