Skip to the record
Mmm.. taste the original NoosaWatch™

Original source · versioned page text

MCU12/0041 Development Application part 2 of 2 Plans and covering letters 429 Kennedys Rd Pomona

of 36

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (21.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
2.    BROODSTOCK MANAGEMENT
      2.1. Collection Methods
      Broodstock would be collected fi..om a number of different
waterways throughout the Mary River Catchment, thus ensuring genetic
diversity. These would include, but not be limited to tributaries, such as
Obi Obi, Six Mile, Coondoo and Tinana. Brood stock sourced from the
Coomera and Pine River systems would be utilised for non
environmental stockings outside the Mary River Catchment. Collection
methods such as Electro fishing, Lure and Line fishing, and gill netting
would be utilised. Best fish handling practises would be as rigorously
adhered to once captured, with the use of non abrasive nets and slings.
      2.2. Handling Treatments
      Once captured the fish will be transported back to the hatchery in
suitably sized tanks with ample clean, fresh water and oxygen. Once back
at the hatchery the fish would be anesthetised with Clove Oil, sexed and

a "PIT"tag placed in the right shoulder. This information would then be

collated in the form of a "Brood stock register"(See Fig 4).
The brood stock would then be placed through a rigorous, veterinary
prescribed, prophylactic treatment regime. The treatment regime would
be carried out in specifically isolated and covered 2000 litre tanks, away
from the main production area.
       2.3. Holding Tanks in Hatchery

       During the hot summer months the Brood stock would be removed
from the ponds and individually housed in 3300 litre tanks inside the
Hatchery Building. These tanks will be linked to a Re-circulated water
treatment system, maintaining optimal water quality parameters. Each

tank will have its own hide/pipe for cover. A detailed "Indoor Brood
stock Placement" register (SeeFig 5)would be established, documenting
tank number, fish PIT tag number, sex and size.
      2.4. Pond Placement
      Brood stock will be placed into ponds when water temperatures
allow, generally around MarchiApril. The ponds will be prepared with
four breeding pipes, of at least two metres in length per pond. These
pipes will be lined with a hard plastic liner and fly screen for the capture
of eggs. Two pairs of similarly sized Brood stock, from varying capture
locations, will be placed into the ponds on the same day to try to alleviate
territorial fighting. A detailed "Pond Placement" register (See Fig 6)will
be established.



                  Prepared for Aquaculture Extension Officer
       Department ofEmployment, Economic Development and Innovation
                              18 February 2012
                             By Darren Knowles
Log in to download the original file

MCU12_0041 Development Application part 2 of 2 Plans and covering letters 429 Kennedys Rd Pomona.pdf · 21.8 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.