Planning Report & Code Assessment · MCU13/0199
KHA DEVELOPMENT MANAGERS TOWN PLANNING REPORT 13268
Transport, Roads and Drainage Code
Erosion and Sediment Control Code
Existing Services Code
Earthworks Code
Waste Management Code
An assessment of the applicable codes has been undertaken by KHA Development Managers and
included in Attachment A. This code assessment has determined that the proposal generally complies
with all probable solutions and specific outcomes. Where probable solutions are not met, an
alternative solution demonstrating compliance with the specific outcome is provided, with the
exception of specific outcomes O7 and O13 of table 11.16 of the Noosaville Locality Code, relating to
density and gross floor area. The following sections detail the alternative solution and outcomes
provided, including sufficient planning grounds to justify the conflicts with specific outcomes.
6.4.1 CODE ASSESSMENT - ALTERNATIVE SOLUTIONS
Noosaville Locality Code - Specific Outcome 09 Setbacks
The proposal is in part setback less than 6m from the front and rear boundaries, with a section of
wall at 4.5m. The garage of each unit is also setback less than 1.5m from the eastern side boundary
at 0.7m. The setback variations are largely proposed due to the site constraint resulting from the 3m
wide sewer easement along the western boundary.
The front and rear setback variations only relate to half the building width and only to the ground
level component of the building. The upper level fully complies with the 6m setback requirement.
The front boundary fence is setback 1m from the boundary and will allow for dense planting to be
provided, achieving an appropriate buffer to the reduced building setback. Similarly buffer planting
can be provided to the rear boundary along the section of reduced setback.
The garage setback is proposed in accordance with The Queensland Development Code, MP1.3
Design and Siting for Duplex Housing, specifically Acceptable solution A2 (d) of Performance Criteria
P2. The proposal complies The Queensland Development Code as follows:
Performance Criteria Acceptable Solution Compliance
P2 Building and structures – d) Subject to A2(c), class 10a buildings
or parts may be within the boundary
(a) Provide adequate daylight and clearances nominated in A2(a) and (b)
ventilation to habitable rooms; and where –
(b) Allow adequate light and ventilation (i) the height of a part within the Complies
to habitable rooms of buildings on boundary clearance is not more The garage wall has both a maximum
adjoining lots. than 4.5m and has a mean height and mean height of 2.6m
of not more than 3.5m; and
(c) Do not adversely impact on the
amenity and privacy of residents on (ii) the total length of all buildings or Complies
adjoining lots. parts, of any class, within the The garage wall length does not
boundary clearance is not more exceed 9m.
than 9m along any one boundary;
and
(iii) the class 10a buildings or parts Complies
within the boundary clearance are The garage wall has a separation
located no closer than 1.5m to a distance greater than 1.5m to the
required window in a habitable adjoining dwelling.
room of an adjoining dwelling.
Development Application For Material Change Of Use Page 10
Multiple Housing – Type 2 Duplex
43 Elizabeth Street, Noosaville
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Report & Code AssessmentRelated documentApplication case desk ↗
About this file
- File size
- 917 KB (small file)
- File type
No other editions are linked here.