Specific Outcomes                           Probable solutions                           Proposal
Flooding and drainage
O17 Buildings and other works are           S17.1 For new buildings or structures        Complies
designed and sited to—                      or additions more than 50m2 gross floor      Development will comply with the
a) provide flood free access to premises    area to an existing building or structure,   minimum floor level requirements. Refer
and flood free habitable areas;             floor levels for habitable rooms are not     to the accompanying Architectural Plans.
b) allow only minor, short term and         less than the specified minimum floor
infrequent flooding of non-habitable        levels
areas;                                      AND
c) ensure drainage does not adversely       S17.2 Where Council infrastructure is        Complies
impact upon other premises; and             available—                                   Drainage will flow to existing drainage
d) ensure filling or excavation does not    any drainage (including buildings and        infrastructure.
adversely impact upon other premises        yards) flows to that infrastructure; and
by—                                         the infrastructure has the capacity to
   i) causing ponding on the site or        accept any additional loading;
nearby land;                                AND
   ii)   increasing    flooding,   which    S17.3 for Residential Uses -                 Complies
adversely affects the safety or use of      where slab on ground construction is         Filling will not exceed more than 1m
any land upstream and downstream;           used, filling does not extend more than      beyond the building footprint from the
and                                         1m beyond the building footprint,            outer walls of the building.
   iii) adversely affecting the flow of     measured from the outer walls of the
water in any overland flow path.            building ; or
                                            the design consists of a suspended floor
                                            construction.
                                            AND
                                            S17.4 Car parking and maneuvering            Complies
                                            areas are constructed at a level that        Car parking and maneuvering areas will
                                            permits the parking area to drain from       be constructed at a level that permits
                                            the site by gravity means, without the       the parking area to drain from the site
                                            need for mechanical pumping;                 by gravity means.
                                            AND
                                            S17.5 Basements for residential uses         Not applicable
                                            have flood immunity above the Q100           No basement level is proposed.
                                            where alternative means to mechanical
                                            pumping are used to achieve such
                                            immunity; or
                                            S17.6 Basements for non-residential          Not applicable
                                            uses have flood immunity above the           No basement level is proposed.
                                            Q100 that may be achieved by means of
                                            mechanical      pumping      where     the
                                            mechanical feature is installed with
                                            adequate holding tanks and an
                                            alternative back up power source.

Sloping sites
O18 Development on sloping sites—           S18.1 Buildings and associated access        Not Applicable
a) is responsive to the natural             ways are not constructed on land with a      The site is not a ‘sloping site’.
topography of the site and minimizes        slope greater than 25% (1 in 4);
cut and fill;                               AND
b) does not visually dominate the hill      S18.2 Buildings are of split level design
slope or interrupt the skyline;             that step down the slope or have
c) is integrated with the natural site      suspended floor construction;
characteristics including vegetation; and   AND
d) for Multiple housing, takes the          S18.3 Cut or fill is less than 2m in
form of small separate buildings;           depth;
                                            AND
                                            S18.4      The distance between the
                                            ground and the lowest part of the floor
                                            of the building does not exceed 3m to
                                            avoid large under building areas;
                                            AND
                                            S18.5 Buildings present no more than 3
                                            storeys at any one point.

O19 On sites which are visible from the     S19.1 No solution provided                   Not applicable
major road network, areas of public                                                      The site is not visible from the major
open space, the Noosa River or the                                                       road network, areas of public open
beaches new buildings and structures                                                     space, the Noosa River or the beaches.
including outbuildings, are designed so

Used in these records

About this file

File size
917 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Planning Report & Code Assessment.pdf · 917 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.