Council archive · source document
Planning Report & Code Assessment · MCU13/0199
Specific Outcomes Probable solutions Proposal
Flooding and drainage
O17 Buildings and other works are S17.1 For new buildings or structures Complies
designed and sited to— or additions more than 50m2 gross floor Development will comply with the
a) provide flood free access to premises area to an existing building or structure, minimum floor level requirements. Refer
and flood free habitable areas; floor levels for habitable rooms are not to the accompanying Architectural Plans.
b) allow only minor, short term and less than the specified minimum floor
infrequent flooding of non-habitable levels
areas; AND
c) ensure drainage does not adversely S17.2 Where Council infrastructure is Complies
impact upon other premises; and available— Drainage will flow to existing drainage
d) ensure filling or excavation does not any drainage (including buildings and infrastructure.
adversely impact upon other premises yards) flows to that infrastructure; and
by— the infrastructure has the capacity to
i) causing ponding on the site or accept any additional loading;
nearby land; AND
ii) increasing flooding, which S17.3 for Residential Uses - Complies
adversely affects the safety or use of where slab on ground construction is Filling will not exceed more than 1m
any land upstream and downstream; used, filling does not extend more than beyond the building footprint from the
and 1m beyond the building footprint, outer walls of the building.
iii) adversely affecting the flow of measured from the outer walls of the
water in any overland flow path. building ; or
the design consists of a suspended floor
construction.
AND
S17.4 Car parking and maneuvering Complies
areas are constructed at a level that Car parking and maneuvering areas will
permits the parking area to drain from be constructed at a level that permits
the site by gravity means, without the the parking area to drain from the site
need for mechanical pumping; by gravity means.
AND
S17.5 Basements for residential uses Not applicable
have flood immunity above the Q100 No basement level is proposed.
where alternative means to mechanical
pumping are used to achieve such
immunity; or
S17.6 Basements for non-residential Not applicable
uses have flood immunity above the No basement level is proposed.
Q100 that may be achieved by means of
mechanical pumping where the
mechanical feature is installed with
adequate holding tanks and an
alternative back up power source.
Sloping sites
O18 Development on sloping sites— S18.1 Buildings and associated access Not Applicable
a) is responsive to the natural ways are not constructed on land with a The site is not a ‘sloping site’.
topography of the site and minimizes slope greater than 25% (1 in 4);
cut and fill; AND
b) does not visually dominate the hill S18.2 Buildings are of split level design
slope or interrupt the skyline; that step down the slope or have
c) is integrated with the natural site suspended floor construction;
characteristics including vegetation; and AND
d) for Multiple housing, takes the S18.3 Cut or fill is less than 2m in
form of small separate buildings; depth;
AND
S18.4 The distance between the
ground and the lowest part of the floor
of the building does not exceed 3m to
avoid large under building areas;
AND
S18.5 Buildings present no more than 3
storeys at any one point.
O19 On sites which are visible from the S19.1 No solution provided Not applicable
major road network, areas of public The site is not visible from the major
open space, the Noosa River or the road network, areas of public open
beaches new buildings and structures space, the Noosa River or the beaches.
including outbuildings, are designed so
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Report & Code AssessmentRelated documentApplication case desk ↗
About this file
- File size
- 917 KB (small file)
- File type
No other editions are linked here.