Council archive · source document
Planning Report & Code Assessment · MCU13/0199
Specific Outcomes Probable solutions Proposal
designed to address any waterfront The site does not have a waterfront
aspect and to contribute positively to aspect.
the waterfront character.
O49 Buildings and structures take the S49.1 Buildings do not contain more Complies
form of small separate buildings, rather than 4 attached dwelling units. The development comprises only 2
than large single bulky developments. attached dwelling units.
Garages and carports
O50 Garages, carport structures and S50.1 Garages and carports— Complies
vehicle manoeuvring areas are designed a) have a front boundary setback of at Garages are integrated in the building
and sited to— least 6m; and design and are not visible from the
a) provide for resident and visitor b) present a minimum width to the street. The garages are setback more
parking; streetscape (the total width of garage than 6m from the front boundary.
b) visually integrate with the building doors is no more than 6m or 50% of the
and to not dominate the street front; frontage width, whichever is the lesser,
c) allow opportunity for landscaping to where the structure faces the street); or
screen vehicle parking and manoeuvring c) that are visible from, but do not face
areas; the street, include windows or other
d) minimise the number of driveway articulation and have a 6m vegetated
accesses; and buffer between the structure and the
e) allow safe and efficient access to and road frontage.
egress from the premises. AND
S50.2 Where multiple lock up garages Complies
face the street garage doors are Garages do not face the street.
stepped back a minimum of 600mm
from each other, in relation to the
frontage or are separated by at least
1.5m;
AND
S50.3 Garages, carports and uncovered Complies
spaces are designed to allow vehicles to Vehicles are able to exit the site in a
enter and exit the site in a forward gear forward motion.
through a 3-point turn maximum;
AND
S50.4 The development provides for Complies
shared driveways to minimise the One access is provided to the street
number of access points, except on sites frontage.
with more than one street frontage,
where garages or carports in the
development front separate streets.
Front fences & walls
O51 Front fences and walls are S51.1 Front fences or walls are setback Complies
designed and sited to— an average of 1 metre and are The proposed front fence is setback 1m
a) contribute to the attractiveness of the articulated to provide visual interest by from the boundary and screened by
street; stepping the design at maximum 5m landscaping.
b) be compatible with the existing intervals.
streetscape character; AND
c) relate to the architectural period of
the building; S51.2 The area of land between the Complies
d) avoid interference with the fence and the front property boundary The area in front of the fence is
movement of surface stormwater; shall be densely landscaped to screen screened with landscaping.
e) allow for casual surveillance from the any fencing from the street.
street or on main roads, mitigate traffic AND
noise;
f) provide for planting in front of high S51.3 Any fencing on the boundary Complies
solid fences and walls; and which is not screened by vegetation is All boundary fences are screened by
g) ensure planting between the front either less than 1.2m high or of an open vegetation, with the exception of the
fence and the footpath does not create construction. built to boundary garage.
an impediment for pedestrians using the
footpath.
See the original