Specific Outcomes                           Probable solutions                            Proposal
                                            S4.2 or S5.1 providing it is accessible for
                                            the purpose of fire fighting at all times
                                            and not used for other domestic
                                            purposes.
Erosion and sediment control
O6 Development does not cause erosion       No solution provided.                         Complies
or result in transport of sediments off-                                                  Development will not cause erosion or
site.                                       Advisory Note                                 result in the transport of sediments off-
                                            Persons    undertaking     development,       site.
                                            including building work, are required
                                            under the Environmental Protection
                                            (Water) Policy 1997 (EPP) to ensure that
                                            sediment and other material including
                                            building waste, sawdust, concrete,
                                            cement or paint are not deposited or
                                            released into a roadside gutter,
                                            stormwater drain or waterway, or into a
                                            place where it could reasonably be
                                            expected to move or be washed into a
                                            roadside gutter, stormwater drain or
                                            waterway and are not washed from the
                                            site. Council enforces the EPP and
                                            penalties may apply.
Safety and security
O7 For Multiple Housing Types 2, 3          S7.1     The building entrance is clearly     Complies
and 4, buildings and outdoor spaces are     identifiable and visible from the street,     The proposed duplex achieves clear,
designed to protect the personal security   footpath and driveway;                        identifiable and visible entrances from
and safety of residents by allowing for                                                   street, footpath and driveway.
natural surveillance.                       AND

                                            S7.2 The internal path network has            Complies
                                            clear sightlines to the dwelling entry and    Pedestrian access to each dwelling unit
                                            street access points;                         entrance has clear sightlines.

                                            AND

                                            S7.3 Visitors have direct access to the       Complies
                                            entrance without passing          through     Direct visitor access to the front door of
                                            private outdoor living areas.                 each dwelling is achieved.
Emergency access
O8 For Multiple housing Type 3, 4 &         No solution provided.                         Not Applicable
5, site design and layout ensures                                                         The proposal is for a Multiple Housing –
efficient access and egress for                                                           Type 2 Duplex development.
emergency vehicles.
Basement drainage
O9 Buildings and access works are           S9.1    Enclosed car parking and              Not Applicable
designed and sited to protect persons       manoeuvring areas are constructed at a        No basement proposed.
and property in the event of a flood and    level that permits the parking area to
power failure.                              drain from the site by gravity means,
                                            without the need for mechanical
                                            pumping.
Separation of incompatible uses
O10 Development is designed to              S10.1 Bedroom windows are at least            Complies
minimise      noise  carrying    between    3m away from shared driveways or              All bedroom windows achieve a
dwelling units or accommodation units       carparking areas of adjacent dwelling         minimum 3m distance facing away from
by locating noise sensitive spaces such     units or accommodation units.                 driveways/ car parking areas and
as      bedrooms    away    from    noise                                                 adjacent dwelling units.
generating areas of the development,
such as carparking areas or mechanic
plant and equipment or recreational
facilities.
Mechanical plant & equipment
O11 Mechanical plant and equipment          S11.1 Mechanical plant and equipment,         Can Comply
associated with Residential Uses are        including pool and spa pumps, pool            Any mechanical plant and or equipment
designed and located so as not have an      heaters, air-conditioning units and           can be visually integrated into the
adverse impact on the visual amenity of     refrigeration units are—                      building plane and roof design and will
the site or surrounding areas.              a) where located at ground level,             not protrude beyond the building height
                                            screened by fencing 1.5m in height or         or when viewed from the street and

Used in these records

About this file

File size
917 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Planning Report & Code Assessment.pdf · 917 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.