Original source · versioned page text
Attachment A Soil reports
Attached to the e-mail MCU14/0103 Development Application - Plans Email 2 of 2.
between any irrigation pipe work and the potable water supply. Any pipe work used for the transport of effluent included treated effluent must be lilac in colour Along the boundary of the surface irrigation area there shall be at least two warning signs clearly visible to inform the occupants of the premises that recycled water is used for irrigation. Each sign shall comply with AS 1319 and have: (a) lettering visible at 3m and (b) wording: Recycled Water Avoid Contact DO NOT DRINK Prior to the use of the system, the warning signs and the landscaping and surface preparation must be completed. The Land Application Area must also be inspected and approved for use by Allgo Waste Management Siting of the Land Application Area: The current Code of Practice for On-site Sewerage Facilities provides minimum horizontal/vertical separation distances for Land Application Areas. They are as follows; Sub-Surface or Covered Surface Land Application Areas(ADVANCED SECONDARY) Property Boundaries Upslope from the Area - 2.0m Property Boundaries Downslope from the Area - 4.0m Dwellings Swimming Pools 5 6.0m In-ground Potable Water Tanks = 15.0m Dams, Watercourses or Bores = 10.0m Vertical distance to water table - 0.6m In no instance shall Effluent be used for irrigation of fruit or vegetables. No Vehicle loading or children’s recreational areas to be applied or constructed within the Land Application Area. System Maintenance: The owner of the property shall ensure that all manufacturers maintenance procedures are undertaken in accordance with the local authority and the manufacturers recommendations for what ever system is installed. The system must be inspected/tested on a regular basis in accordance with the manufacturers requirements and all Statutory requirements from relevant local and state government agencies. System Installation: Installation of the system must be undertaken by a qualified plumber in accordance with local authority requirements and in accordance with the relevant Australian Standards and Australian Building Code. Definitions: Design Loading Rate (DLR) The long term acceptance rate (LTAR), reduced by a factor of safety, expressed in L/m?/day or mm/day as applied to the horizontal design area of a land application system. AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 140120(A)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.