4.6 Sustainable Building Design Code
An assessment against the Performance Outcomes (PO8) of the Sustainable Building Design
Code is provided below.
Performance Outcome Comment
orientates buildings and The design includes glazing and inside outside connection
windows to make the most of which allows good flow through ventilation. Kitchen, living
prevailing winds, natural and deck areas of both units face north and west and make
ventilation, and cross breezes; use of the winter sun and cooling summer breezes.
maximises shade to east and The upper floor and veranda roofs act to shade walls and the
west walls; orientation minimises the effect of the west afternoon sun with
wide balcony roofs.
contains an open and The design creates good flow and permeability to the large
permeable built form that decks which create an inside outside feel to the living areas,
connects indoor and outdoor particularly the use of glazing enhances the indoor outdoor
spaces in an integrated design; connection.
retains existing vegetation and Although not retaining trees, the design proposes large
natural shading where possible; plantings throughout the site demonstrated by the proposal
having more landscaping than that required by the zone
code.
incorporates The architecturally designed proposal has strategically
passive building design to placed openings, masonry walls and LOS to help with thermal
reduce the need for auxiliary comfort. Most units have a northern aspect and east facing
heating and cooling; POS and LOS to maximise the northern and eastern aspect
of the western facing lot.
uses low toxic internal and A mix of low toxic internal and external materials are
external building materials; incorporated for the construction which will ensure long
lasting design that does not require regular maintenance.
uses natural light rather than Natural light is provided through the strategically located
artificial light, and may include opening and glazing on both levels.
skylights, atriums and light
wells;
provides a minimum floor to The design proposes 2.7m floor to ceiling heights allow for
ceiling height of 2.7 metres; and good room air circulation.
enables efficient operation and The design allows for medium density living and privacy to
use of the building. each of the dwellings, while also allowing for users to easily
flow between the main living and bedroom levels.
4.7 Works Codes
Recor Engineers include preliminary earthworks, stormwater and traffic turning plans in accordance
with the relevant works codes. Stormwater is collected along the northern boundary and treatment
methods seek the removal of water contaminants of the building and driveways within an
underground rainwater tank.
Page 10 of 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
planning report bottlebrush 17.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.