                     ENERGY EFFICIENCY
            TO MEET MINIMUM 6 STARS BERS RATING                                                                                                                                                                                                                                                                                                                                                                        Scale 1:100
                                                                                                                                                                                                                                                                                                                                                                                                                                     1    0           1   2      3        4       5m

            GENERAL NOTES
    ·       CONFIRM ALL DIMENSIONS ON SITE TO EXISTING
            RESIDENCE PRIOR TO COMMENCEMENT OF ANY
            WORK.
    ·       SUPPLY & INSTALL 'BIFLEX CHEMICAL TERMITE
            TREATMENT (UNLESS OTHERWISE APPROVED) TO
            COMPLY WITH AS3660.1 AND MANUFACTURER'S
            SPECIFICATIONS
    ·       ALL BRICKWORK (INCLUDING BRICK VENEER),
            SHALL BE IN ACCORDANCE WITH AS3700-
            MASONRY CODE                                                                                                                                                                                                                                                                                                                                            existing laundry annex to be demolished
    ·       ALL TIMBER FRAMING SHALL BE IN ACCORDANCE
            WITH AS1684. - UNLESS OTHERWISE APPROVED
            ROOF FRAMING SHALL BE OF TRADITIONAL FRAMED
            CONSTRUCTION.
    ·       FOR ALL STRUCTURAL MEMBERS, FOOTINGS &                                                                                                                                                                                                                                                                                                                  existing kitchen niche to be removed
            LOAD BARING WALLS REFER TO STRUCTURAL
            DOCUMENTATION PREPARED BY ENGINEERS.
    ·       ELECTRICIAN TO SUPPLY AND INSTALL APPROVED
            HARDWIRED SMOKE ALARMS IN ACCORDANCE
            WITH AS3786 (NEW LOCATIONS TO BE INDICATED                                                          enclosed bedroom annex to be
            SD)
    ·       ALL ELECTRICAL WORK TO BE CARRIED OUT IN
                                                                                                               demolished from main structure
            ACCORDANCE WITH AS3000.
    ·       ALL PLUMBING & DRAINAGE WORK TO BE CARRIED
            OUT IN ACCORDANCE WITH AS3500.



            DEMOLITION NOTES (AS APPLICABLE)
·           CAP OFF EXISTING PLUMBING AND ELECTRICAL
            WORKS AS NECESSARY BY CERTIFIED
            TRADESPERSON.
                                                                                                                                                                                                                                                 subfloor setout
·           MATERIALS REMOVED FROM SITE MUST BE
                                                                                                                                                                                                                                                   (indicative)
            DISPOSED OF AS PER COUNCIL REGULATIONS.                                                                                                                                                                                                                                                                                                                              existing timber & concrete steps
·           INVESTIGATON SHOULD BE UNDERTAKEN BEFORE
            ALL WORKS THAT REQUIRES EXCAVATION.                                                                                                                                                                                                                                                                                                                                  to entry to be removed
·           DEMOLITION WORK TO BE CARRIED OUT AS PER
            WHS REGULATORY REQUIREMENTS




             FLOOR PLAN NOTES
        •    APPLIANCES/FURNITURE (NOT FIXED) ARE NOT
             INCLUDED WITHIN BUILD CONTRACT UNLESS
             OTHERWISE SPECIFIED
        •    ALL PLUMBING FIXTURES TO BE WELS RATED
        •    DOOR FRAME HEIGHTS INT. 2090 EXT. 2135
        •    BULKHEAD MAY BE REQUIRED TO ACCOMMODATE                                                                                                                                                                                                                                                                                                                existing hot water unit
             SERVICES AND STRUCTURAL DESIGN. FINAL
             LOCATION & SIZE TO BE DETERMINED ON SITE.
        •    PROVIDE ADDITIONAL NOGGINGS @ 1200mm FOR                                                                                                                                                                                                                                          HW
                                                                                                                                                                                                                                                                                               HWS
             TOWEL RAIL & 800mm FOR TOILET ROLL HOLDER
             WHERE APPLICABLE.

                                                                                                                                                                                                                                                                                                                                                                    timber bearers




                                                                                                                                                                                                                                                                                                                  M/B
                                                                                                                                                                                                                                                                                                                                                                    existing electrical meter box




                                                                                                                                                                                                                                                   S-01




             NOTES                                                                                                                                                                                                                                                                                                                                                                                                                            SCHEDULE
                                                                                                                                                                                                                                                                                                                                                                                                                                                                   EXISTING STRUCTURE
        •    APPLIANCES/FURNITURE (NOT FIXED) ARE NOT                                                                                                                                                                                                                                                                                                                                                                                                                  (DENOTED BLACK)
             INCLUDED WITHIN BUILD CONTRACT UNLESS
                                                                                                                                                                                                                                                                                                                                                                                                                                                                DEMOLISHED STRUCTURE
             OTHERWISE SPECIFIED                                                                                                                                                                                                                                                                                                                                                                                                                                        (DENOTED RED)
        •    ALL PLUMBING FIXTURES TO BE WELS RATED
        •    DOOR FRAME HEIGHTS INT. 2090 EXT. 2135




                                                                                                                                                      NOTE:                                                                                                                                                                                                                                                                 Job No.
                                                                                                                                                                                                                        GROUND FLOOR - EXISTING / DEMOLITION PLAN NORTH
                                                                                                                                                                                                                                                                                                                                                                                                                                              AD21-002
                                                                            antoniajayne Design                                                       ALL DESIGN, CONSTRUCTION & MATERIALS TO BE IN ACCORDANCE WITH:
                                                                                                                                                      •THE NATIONAL CONSTRUCTION CODE (NCC)
                                                                                                                                                      •THE BUILDING CODE OF AUSTRALIA (BCA)
                                                                                                                                                                                                                                                                                                                                                                                                                            Issue             DEVELOPMENT APPROVAL - client amendments
                                                                                                                            0409 366 854              •THE QUEENSLAND DEVELOPMENT CODE (QDC)
                                                                                                                                                                                                                                                                                                                                                                                                                            Rev               06
                                                                                                                                                      •BUILDING REGULATIONS & LOCAL GOVERNMENT PLANS & POLICIES
                                                                                                             North Booval QLD 4304
                                                                                            [email protected]
                                                                                                                                                      •CURRENT ISSUES OF AUSTRALIAN STANDARDS
                                                                                                                                                      •CURRENT MANUFACTUERER'S SPECIFICATIONS & INSTALLATION DETAILS    AD21-001_13RECTORYSTREET                                                     Kate Mayne & Kent Mayne                                                                                                Date              18/2/22
                                                                                                                                                      FOR MATERIALS USED

                                                                                                               www.ajdesigndp.com                     ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE NOTED
                                                                                                                                                                                                                                                                                                                                                                                                                            Page No.          A.02
                                                                                                                          QBCC: 15133061                                                                                FOR APPROVAL                                                                  13 Rectory Street Pomona QLD 4568
                                                                                                                                                                                                                                                                                                                                                                                                                            Scale @ A3        1:100
        Copyright: This drawings remains the property of antoniajayne Design and is provided for use as noted the recipient(s) of this document is/
        are prohibited from disclosing such information, ideas and concepts to any person without prior written consent of the copyright holder.                                                                       /Users/antoniajayne/Library/Mobile Documents/com~apple~CloudDocs/OBRIEN & DOYLE GROUP_ICLOUD/ANTONIAJAYNEDESIGN_ICLOUD/JOBS/AD21-001_13RECTORYSTREET/ARCHICAD/AD21-001_13RECTORYSTREET_V2.pln        Prepared by       ANTONIA O'BRIEN
Log in to download the original file

Appendix A - Amended Plans.pdf · 5.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.