Council archive · source document
15320 RevA A1 signed · OPW16/0161
Attached to the e-mail OPW16/0161 - Operational Works Application.
Lionel Ferris RPEQ 5938 2016.07.29 09:40:39 +10'00' [OCR of page images] S ge 7 £ SP #40 ZB e Zz be OG #42 9 i we = wo B sew Su Hix “Spe BB * S Yon whe a7 N » & Sy FES Z Ss @ ge a dD »- iw U1004745, i 2 OY eS ™ — oO het eS cas 2 gh LP257575_\\~ ~ ooh \ 9! 2 = B wr? \% \ \% \~% 3 \S \9 \ ro Q\y’ EX 300AL 30 ¥ IN 16LV wi o® _ \ a7 \ aq \ \ 7 our ) sar Lae v \ “7 - $C762502 Lage «) 27 27 2 2 C o-7 863938 pa EXISTING & PROPOSED LV SCHEMATIC HAND SINK DANGER LIVE 11kV & LV CABLES #1 © & “7 \e QV, ww ro SY ae 2 eee ae ay & BE BOER w \ #8 oS eee BS ZEB < ee C2 Sp Ze % Ce % SCALE 1:1000 20 0 20 40 60 80 100 METRES jt ls SCALE 1:1000 (BEFORE REDUCTION) * ASSUMED EXISTING CONDUIT ARRANGEMENT SCALE 1:2500 NOTES SUPPLY TO BE MADE AVAILABLE TO PROPOSED LOTS 1 & 2 AS PER THE ENERGEX REQUIREMENTS & EMAIL 24/6/2016. 2. AT STN’S 2, 3, 4 & 5 HAND EVACUATE & LOCATE THE ASSUMED EXISTING X/RD CONDUITS. 3. CONFIRM IF EXISTING CONDUITS ARE SUITABLE & CONTINUOUS TO INSTALL THE 16(LV) X/ROAD CABLE AS PER ENERGEX EMAIL 24/6/2016. IF ADDITIONAL BORED CONDUITS ARE REQUIRED, THE OWNERS ARE TO BE NOTIFIED OF ANY WORKS & VARIATION TO COSTS. 4. AT STN’S 2 & 4, HAND EXCAVATE & INSTALL 16(LV) CABLES AND BRIDGE IN. 5. DANGER - EXISTING MAJOR SERVICES IN ALL AREAS. CHECK CLEAR WITH ALL SERVICES & LOCATE TO IDENTIFY. 6. NOTIFY EXISTING CUSTOMERS AT #7 & #13 OF PROPOSED DATE & TIMES FOR INTERRUPTION TO SUPPLY. 7, REINSTATE FOOTPATH TO COUNCIL REQUIREMENTS. Underground Legend Existing Proposed Recovered Description |] © ondllv. 6 O 2000 BR @ 260 kv @ 4 HV U/G Pole Termination LV U/G Pole Termination U/G Disconnect Links Pillar Link Pillar Padmount Transformer Ring Main Unit LV Switchboard Ground Transformer U/G Mains Street Light (CFL32) U/G Conduits (Trench X) Streetlight Conduit Spare 100mm Conduit ENERGEX Communication Conduit Spare 125mm Conduit @ 240 tv U/G Cable laid in Conduit (LV Or HV) Electronic Cable Marker Earth EQUIPMENT SCHEDULE - SERVICE PILLARS STN LOCATION No SITE ID EXIST REC INSTALL SIZE & DESCRIPTION HIN COMP ID PLANT No MODEL ID Qty Lec REMARKS RAVENWOOD DRIVE 2 U30-U PI EXISTING 2 WAY ELECTRICITY SUPPLY PILLAR 1 BRIDGE IN 16 Cu 4€ LV. 3 U1326236 CROSS ROAD PILLAR,S/L Pit LVSP12-6SL 1 LOT 1 AND EX. #7 4 U31-1 Pl2 EXISTING 2 WAY ELECTRICITY SUPPLY PILLAR. 1 BRIDGE IN 16 Cu 4C LV. 5 U1326237 HK eK CROSS ROAD PILLAR, S/L Pil LVSP12-6SL 1 LOT 2 AND EX. #13 TAPE SET 1038-1 1 UNDERGROUND CABLE SCHEDULE STATIONS LOCATION FROM-TO VOLTS EXIST REC | INSTALL CABLE SIZE/TYPE CABLE ROUTE LENGTH (m) MODEL 1D LENGTH (m) Lcc NEW REC REMARKS RAVENWOOD DRIVE 2 --- 3 tomm? CU 4C XL * PE/PVC LVC416XPV 16 20 TRANSFER EX CONSUMERS MAINS OF HOUSE #7 INTO NEW STN 3. RECOVER EXCESS CABLE ORIGINALLY FROM STN 2 4 ---5 Tomm? CU 4C XL * PE/PVC LVC416XPV 20 24 TRANSFER EX CONSUMERS MAINS OF HOUSE #13 INTO NEW STN 5. RECOVER EXCESS CABLE ORIGINALLY FROM STN &. ALL STREETS AT PILLARS * Tomm? Cu 4C PV C/PVC LVC416XPV - 3 VARIANCE 2% TOTALS ‘tomm? Cu &C XL! PE/PVC LVC416XPV 36 47 NOTES 1. THE CONTRACTOR SHALL MEASURE ACTUAL CABLE LENGTHS REQUIRED AFTER INSTALLATION OF CONDUITS, THEN ORDER CABLE ACCORDINGLY. ALIGNMENT NOTE ) UNDERGROUND SERVICES IDENTIFICATION Work crews who will be excavating at this site are advised to contact the “Queensland Dial Before You Dig” service to determine the extent of existing underground services and the requirements of the appropriate service providers It is the responsibility of the works crews to have all existing services affected by these works located on site to avoid any damage during excavation works. Where services have been shown on the plan, these locations are indicative only and no warranty is implied as to their accuracy DIAL 1100 yf) BEFORE YOU DIG QLD DIAL BEFORE YOU DIG SERVICE PHONE 1100 FAX 1300 652 077 YOUR REQUEST SHOULD BE FORWARDED 5 WORKING DAYS BEFORE PLANNED EXCAVATION DATE. XN (— SPECIFICATION IN BRIEF This Works Plan is to be constructed in compliance with Energex documents: + Overhead Construction Manual + Underground Distribution Construction Manual + Network Labelling and Signage Manual ~ The project is to be managed by a Project Manager in accordance with Energex SWP47.2, who may also be the Electrical Construct Provider (Contractor). ‘As Constructed’ drawings and the Certificate of Completion to be submitted to Energex by the Project Manager. EXISTING SERVICES The Contractor is to confirm positions/locations of all existing services. Where services have been shown on the plan, these locations are indicative only. The Contractor shall co-ordinate the installation with relevant utilities and residents. CROSS ROAD CONDUITS Unless specified the Civil Contractor will install all cross road conduits. TELSTRA INSTALLATION Telstra conduits to be laid in shared trenches with electricity conduits. The Civil/ Electrical Contractor is to notify the Telstra Contractor one week prior to installation of cross road conduits and two days prior to installation of footpath conduits EARTHING Earthing to be carried out in accordance with Energex requirements. For Telstra plant 15 metres separation shall apply for separate earthing and one metre separation for common earthing. For further details refer to Telstra earthing policy. FIRE ANTS The Contractor is to confirm if this work site is within a Fire Ant Restricted Area. Refer to DPI Fire Ant Restricted Area Map (www.dpi.qid.gov.au). For work sites within a Fire Ant Restricted area the Contractor must comply with a DPI Approved Risk Management Plan. J A Original Issue D.B. | 27/07/2016 ISSUE} REVISION BY DATE ALIGNMENTS REFERENCE ENERGEXOH N/A COUNCIL NOOSA ENERGEXUG — 0-900mm UBDREF SC 9/F13 STREET LIGHTS EXISTING PEGGED? ( > COMMISSIONING PLAN Proposed only and subject to alteration by Energex. 1. AT STN'S 2 & 4 - BRIDGE IN PROPOSED 16 (LV) CABLE 2. LV SWITCHING ONLY REQUIRED. S NK r > Millwell Services Pty Ltd ABN 12 115 160 748 PROJECT DESIGN . OVERHEAD & UNDERGROUND phone:(07) 5479 1368 fax:(07) 5443 3867 email: [email protected] web:www.millwell.com.au PO Box 807 Maroochydore Qld 4558 Drafted Desired DB. N.N. Date Checked P. Jansen 27.07. 2016 APPROVED FOR AND ON BEHALF OF MILLWELL SERVICES PTY LTD Lionel Ferris AT RPEQ 5938 KL aE 2016.07.29 09:40:39 +10'00' Scale 1:1000 Drawing No Issue 15320 1071 | A This design and drawing is copyright and is not to be used or reproduced \_wholy or in part without the written permission of Milwell Services Pty Ltd} (Project ~ 9 RAVENWOOD DRIVE NOOSA HEADS, QLD 4567 PROPOSED TWO LOTS PROPOSED LOTS 1 & 2 CANCELLING LOT 70 - RP217095 r CONTACT DETAILS Energex Project No $31000267 SOURCE DOCUMENTS AUTHOR REV DRAWING No DRG. NO, DATE MAX WATTERSON & ASSOC SURVEY PLAN S$P281580 - NOOSA COUNCIL DECISION NOTICE REC1S/0023 - 07/01/16 ENERGEX MAINS MAP. EMAIL. 31/05/16 CIVIL ENGINEER NA Client Mr MURRAY LYONS SURVEYOR MAX WATTERSON & ASSOCIATES Ph: (07) 54 426 121 Drawing Title DESIGN FOR ELECTRICAL RETICULATION SITE PLAN & LV SCHEMATICS XN S
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
15320 RevA A1 signed.pdfRelated documentApplication case desk ↗
About this file
- File size
- 502 KB (small file)
- File type
No other editions are linked here.