Skip to the record
Noosa's #1 Council Tracker.

Council archive · source document

15320 RevA A1 signed · OPW16/0161

Attached to the e-mail OPW16/0161 - Operational Works Application.

of 1

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Lionel Ferris
RPEQ 5938
2016.07.29 09:40:39
+10'00'


[OCR of page images]
 

 

 

S
ge
7 £
SP #40
ZB
e Zz
be
OG #42 9
i we = wo
B sew Su Hix
“Spe BB *
S Yon whe a7 N »
& Sy FES Z Ss @
ge a dD
»-

iw

U1004745, i
2 OY
eS
™

—
oO

 

het eS

cas

2 gh
LP257575_\\~ ~ ooh \
9! 2
= B wr? \%
\ \%
\~%
3
\S
\9
\
ro
Q\y’
EX 300AL 30 ¥ IN 16LV
wi o® _
\ a7
\ aq
\ \ 7 our
) sar
Lae v
\ “7 - $C762502
Lage «)
27 27
2 2
C o-7
863938 pa

EXISTING & PROPOSED LV SCHEMATIC

 

 

 

 

 

HAND SINK
DANGER LIVE 11kV

& LV CABLES

 

 

 

 

 

 

 

#1

©
& “7
\e QV,
ww ro
SY ae 2 eee
ae ay & BE BOER
w \ #8 oS eee BS
ZEB < ee
C2 Sp Ze
% Ce
%
SCALE 1:1000
20 0 20 40 60 80 100 METRES

jt ls

SCALE 1:1000 (BEFORE REDUCTION)

* ASSUMED EXISTING

CONDUIT ARRANGEMENT

SCALE 1:2500

NOTES

SUPPLY TO BE MADE AVAILABLE TO
PROPOSED LOTS 1 & 2 AS PER THE ENERGEX
REQUIREMENTS & EMAIL 24/6/2016.

2. AT STN’S 2, 3, 4 & 5 HAND EVACUATE &
LOCATE THE ASSUMED EXISTING X/RD
CONDUITS.

3. CONFIRM IF EXISTING CONDUITS ARE SUITABLE
& CONTINUOUS TO INSTALL THE 16(LV)
X/ROAD CABLE AS PER ENERGEX EMAIL
24/6/2016.

IF ADDITIONAL BORED CONDUITS ARE
REQUIRED, THE OWNERS ARE TO BE NOTIFIED
OF ANY WORKS & VARIATION TO COSTS.

4. AT STN’S 2 & 4, HAND EXCAVATE & INSTALL
16(LV) CABLES AND BRIDGE IN.

5. DANGER - EXISTING MAJOR SERVICES IN ALL
AREAS. CHECK CLEAR WITH ALL SERVICES &
LOCATE TO IDENTIFY.

6. NOTIFY EXISTING CUSTOMERS AT #7 & #13 OF
PROPOSED DATE & TIMES FOR INTERRUPTION
TO SUPPLY.

7, REINSTATE FOOTPATH TO COUNCIL
REQUIREMENTS.

 

Underground Legend

 

Existing

Proposed

Recovered Description

 

 

|] © ondllv.

6

O
2000 BR

@ 260 kv

@
4

HV U/G Pole Termination

LV U/G Pole Termination
U/G Disconnect Links

Pillar
Link Pillar

Padmount Transformer

Ring Main Unit

LV Switchboard
Ground Transformer

U/G Mains
Street Light (CFL32)

U/G Conduits (Trench X)

Streetlight Conduit
Spare 100mm Conduit
ENERGEX Communication Conduit
Spare 125mm Conduit
@ 240 tv U/G Cable laid in Conduit (LV Or HV)
Electronic Cable Marker

Earth

 

EQUIPMENT SCHEDULE - SERVICE PILLARS

 

STN

LOCATION No

SITE ID

EXIST

REC

INSTALL

SIZE & DESCRIPTION

HIN

COMP
ID

PLANT

No MODEL ID

Qty Lec

REMARKS

 

 

RAVENWOOD DRIVE 2 U30-U

PI

EXISTING 2 WAY ELECTRICITY SUPPLY PILLAR

1 BRIDGE IN 16 Cu 4€ LV.

 

3 U1326236

CROSS ROAD PILLAR,S/L

Pit

LVSP12-6SL 1 LOT 1 AND EX. #7

 

4 U31-1

Pl2

EXISTING 2 WAY ELECTRICITY SUPPLY PILLAR.

1 BRIDGE IN 16 Cu 4C LV.

 

5 U1326237

HK eK

CROSS ROAD PILLAR, S/L

Pil

LVSP12-6SL 1 LOT 2 AND EX. #13

 

 

 

 

 

 

TAPE SET

 

 

 

 

1038-1 1

 

 

 

 

 

 

 

UNDERGROUND CABLE SCHEDULE

 

STATIONS

LOCATION FROM-TO

VOLTS

EXIST

REC | INSTALL

CABLE SIZE/TYPE

CABLE

ROUTE LENGTH (m)

MODEL 1D LENGTH (m)

Lcc

 

NEW REC

REMARKS

 

RAVENWOOD DRIVE 2 --- 3

tomm? CU 4C XL

*

PE/PVC

LVC416XPV 16 20

TRANSFER EX CONSUMERS MAINS OF HOUSE #7 INTO NEW STN 3.
RECOVER EXCESS CABLE ORIGINALLY FROM STN 2

 

4 ---5

Tomm? CU 4C XL

*

PE/PVC

LVC416XPV 20 24

TRANSFER EX CONSUMERS MAINS OF HOUSE #13 INTO NEW STN 5.
RECOVER EXCESS CABLE ORIGINALLY FROM STN &.

 

ALL STREETS AT PILLARS

*

Tomm? Cu 4C PV

C/PVC

LVC416XPV - 3

 

VARIANCE 2%

 

TOTALS

 

 

 

 

 

 

‘tomm? Cu &C XL!

 

 

PE/PVC

LVC416XPV 36 47

 

 

 

 

 

 

 

 

NOTES

1. THE CONTRACTOR SHALL MEASURE ACTUAL CABLE LENGTHS REQUIRED AFTER INSTALLATION OF CONDUITS, THEN ORDER CABLE ACCORDINGLY.

 

ALIGNMENT NOTE )

UNDERGROUND SERVICES IDENTIFICATION

Work crews who will be excavating at this site are
advised to contact the “Queensland Dial Before
You Dig” service to determine the extent of
existing underground services and the
requirements of the appropriate service providers
It is the responsibility of the works crews to have
all existing services affected by these works
located on site to avoid any damage during
excavation works. Where services have been shown
on the plan, these locations are indicative only and
no warranty is implied as to their accuracy

DIAL 1100

yf) BEFORE YOU DIG

 

  

 

QLD DIAL BEFORE YOU DIG SERVICE
PHONE 1100 FAX 1300 652 077

YOUR REQUEST SHOULD BE FORWARDED 5 WORKING
DAYS BEFORE PLANNED EXCAVATION DATE.

XN

(— SPECIFICATION IN BRIEF

This Works Plan is to be constructed in compliance with Energex documents:
+ Overhead Construction Manual

+ Underground Distribution Construction Manual

+ Network Labelling and Signage Manual

 

~

The project is to be managed by a Project Manager in accordance with Energex
SWP47.2, who may also be the Electrical Construct Provider (Contractor).

‘As Constructed’ drawings and the Certificate of Completion to be submitted to
Energex by the Project Manager.

EXISTING SERVICES

The Contractor is to confirm positions/locations of all existing services. Where
services have been shown on the plan, these locations are indicative only. The
Contractor shall co-ordinate the installation with relevant utilities and residents.

CROSS ROAD CONDUITS
Unless specified the Civil Contractor will install all cross road conduits.

TELSTRA INSTALLATION

Telstra conduits to be laid in shared trenches with electricity conduits. The Civil/
Electrical Contractor is to notify the Telstra Contractor one week prior to installation
of cross road conduits and two days prior to installation of footpath conduits

EARTHING

Earthing to be carried out in accordance with Energex requirements. For Telstra
plant 15 metres separation shall apply for separate earthing and one metre
separation for common earthing. For further details refer to Telstra earthing policy.

FIRE ANTS

The Contractor is to confirm if this work site is within a Fire Ant Restricted Area.
Refer to DPI Fire Ant Restricted Area Map (www.dpi.qid.gov.au).

For work sites within a Fire Ant Restricted area the Contractor must comply with a
DPI Approved Risk Management Plan. J

 

 

 

 

 

 

 

 

 

A Original Issue D.B. | 27/07/2016

 

ISSUE} REVISION BY DATE

 

 

 

 

ALIGNMENTS REFERENCE

 

ENERGEXOH N/A COUNCIL NOOSA

 

ENERGEXUG — 0-900mm UBDREF SC 9/F13

 

STREET LIGHTS EXISTING PEGGED?

 

 

 

 

( >
COMMISSIONING PLAN

Proposed only and subject to alteration by Energex.

1. AT STN'S 2 & 4 - BRIDGE IN PROPOSED 16 (LV) CABLE
2. LV SWITCHING ONLY REQUIRED.

 

S

 

NK
r >
Millwell Services Pty Ltd

ABN 12 115 160 748
PROJECT DESIGN . OVERHEAD & UNDERGROUND

phone:(07) 5479 1368
fax:(07) 5443 3867

email: [email protected]
web:www.millwell.com.au

PO Box 807
Maroochydore Qld 4558

 

Drafted

Desired DB. N.N.

 

Date

 

Checked P. Jansen 27.07. 2016

 

APPROVED FOR AND ON BEHALF OF MILLWELL SERVICES PTY LTD

Lionel Ferris
AT RPEQ 5938
KL aE

2016.07.29 09:40:39
+10'00'

 

Scale

1:1000

 

Drawing No Issue

15320 1071 | A

 

 

This design and drawing is copyright and is not to be used or reproduced
\_wholy or in part without the written permission of Milwell Services Pty Ltd}

 

 

(Project ~
9 RAVENWOOD DRIVE
NOOSA HEADS, QLD 4567
PROPOSED TWO LOTS

PROPOSED LOTS 1 & 2
CANCELLING LOT 70 - RP217095

 

r
CONTACT DETAILS

Energex Project No

$31000267

 

SOURCE DOCUMENTS

 

AUTHOR

REV

DRAWING No

DRG. NO,

DATE

 

MAX WATTERSON & ASSOC

SURVEY PLAN S$P281580 -

 

NOOSA COUNCIL

DECISION NOTICE REC1S/0023 -

07/01/16

 

 

ENERGEX

 

 

 

MAINS MAP. EMAIL.

 

31/05/16

 

CIVIL ENGINEER

NA

Client

Mr MURRAY LYONS

 

 

SURVEYOR

MAX WATTERSON & ASSOCIATES
Ph: (07) 54 426 121

 

 

Drawing Title

DESIGN FOR
ELECTRICAL RETICULATION

SITE PLAN & LV SCHEMATICS

 

 

XN S

 

 

 

 

 

 

Used in these records

About this file

File size
502 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

15320 RevA A1 signed.pdf · 502 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.