Council archive · source document
SUPERSEDED - Approved Plans 51988.63.01
Plans and drawings: the text below has words only, no drawings.
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.01 30 MAR 2016
E
D
C
B
PROPOSED ADDITIONS
PROPOSED EXISTING
ADDITIONS BUILDING
23500
A
12 11 10 9 8 7 6 5 4 3 2 1
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
AREA SCHEDULE
SITE PLAN
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
1 1 : 500 NORTH
ADDITIONS GROUND FLOOR
ADDITIONS MEZZANINE
715.86
198.55
EXISTING BUILDING 848.72
Grand total 1763.13
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 SITE PLAN
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 09-Feb-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 4:19:09 PM 1 : 500
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK101 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 6 pages
Page 2
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.01 30 MAR 2016
33085
E
5600
D
C
UP
B
23500 PROPOSED ADDITIONS
29900
PROPOSED EXISTING
R
OVE
ADDITIONS BUILDING
INE
ZAN
715sqm 850sqm
MEZ
UP NORTH
A
12 11 10 9 8 7 6 5 4 3 2 1
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
AREA SCHEDULE
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
ADDITIONS GROUND FLOOR 715.86
GROUND FLOOR PLAN
1 1 : 200
ADDITIONS MEZZANINE
EXISTING BUILDING
198.55
848.72
Grand total 1763.13
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 GROUND FLOOR PLAN
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 09-Feb-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 4:19:10 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK102 1
Page 3
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.01 30 MAR 2016
E
D
C
UP
B
PROPOSED VOID TO NEW VOID TO EXISTING
MEZZANINE GYM BELOW GYM BELOW
LEVEL
198sqm
UP NORTH
A
12 11 10 9 8 7 6 5 4 3 2 1
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
MEZZANINE FLOOR PLAN
1 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 MEZZANINE FLOOR PLAN
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 09-Feb-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 4:19:11 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK103 1
Page 4
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.01 30 MAR 2016
33085
E
5600
D
C
B
23500 PROPOSED ADDITIONS
29900
PROPOSED EXISTING
ADDITIONS BUILDING
A NORTH
12 11 10 9 8 7 6 5 4 3 2 1
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
ROOF PLAN
1 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 ROOF PLAN
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 09-Feb-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 4:19:11 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK104 1
Page 5
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
12 11 10 9 8 7 6 5 4 3 2 1
7500
RL 17.500
5135
RL 15.135 3900
3000 RL 13.900
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
South Elevation
1 1 : 200 29100 EXISTING BUILDING 30250 PROPOSED ADDITIONS
1 2 3 4 5 6 7 8 9 10 11 12
7500
RL 17.500
5135
3900 RL 15.135
RL 13.900 3000
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
North Elevation
4 1 : 200
D D
A B C E E C B A
7500
RL 17.500
5135
RL 15.135 3900
3000 RL 13.900
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
East Elevation West Elevation
3 1 : 200
2 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 ELEVATIONS
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
- COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
NOOSA COUNCIL RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH DRAWN PROJECT No PLOT DATE
09-Feb-16
SCALE
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 4:19:14 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
APPROVED PLAN 5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF
23 PALUMA ST SUNRISE BEACH QLD 4567 DRAWING No REVISION
CONSTRUCTION
51988.63.01 30 MAR 2016 6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK201 1
Page 6
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
12 11 10 9 8 7 6 5 4 3 2 1
7500
RL 17.500
5135
RL 15.135 3900
3000 RL 13.900
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
SECTION A
A 1 : 200
29100 EXISTING BUILDING 30250 PROPOSED ADDITIONS
1 2 3 4 5 6 7 8 9 10 11 12
7500
RL 17.500
5135
3900 RL 15.135
RL 13.900 3000
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
D
SECTION B
B 1 : 200
A B C
7500
6500 RL 17.500
6000
RL 16.500
RL 16.000
3000
RL 13.000
GROUND GROUND
RL 10.000 RL 10.000
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
SECTION C
C 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 SECTIONS
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
- COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
NOOSA COUNCIL RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH DRAWN PROJECT No PLOT DATE
09-Feb-16
SCALE
Paul Hindes 1127 4:19:15 PM 1 : 200
APPROVED PLAN HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF
QBSA Lic 1160074 ‐ ABN 81600841459
23 PALUMA ST SUNRISE BEACH QLD 4567 DRAWING No REVISION
CONSTRUCTION
51988.63.01 30 MAR 2016 6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK203 1
Page 7
PROPOSED ADDITIONS FROM NORTH-WEST
3
VIEW 1
1
PROPOSED ADDITIONS FROM SOUTH-WEST
4
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
VIEW 2
2
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 VIEWS
A3
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
- COMMENCING FABRICATION [email protected]
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
NOOSA COUNCIL RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH DRAWN PROJECT No PLOT DATE
09-Feb-16
SCALE
Paul Hindes 1127 4:19:17 PM
APPROVED PLAN HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF
QBSA Lic 1160074 ‐ ABN 81600841459
23 PALUMA ST SUNRISE BEACH QLD 4567 DRAWING No REVISION
CONSTRUCTION
51988.63.01 30 MAR 2016 6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK601 1
Used in these records
SUPERSEDED - Approved Plans 51988.63.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 769 KB (small file)
- File type
No other editions are linked here.