16144-Code-Water Sensitive Design Code
Attached to the e-mail Response to Information Request MCU16/0079 (email 1 of 3).
1 Memorial Avenue Tewantin, QLD 4565
Water Sensitive Design Code
Water Sensitive Design Code
Specific Outcome Acceptable Solutions/Probable Solutions Compliance
that allows alternate use of captured (SQID) and discharged to the stormwater
water or the reticulated water supply is network. Refer to SBSWMP.
installed to ensure that there is a
continual supply of water for sanitary
flushing and laundry use.
O4 On-site detention does not adversely impact on water S4.1 No solution provided There is no on-site stormwater detention
requirements downstream of the site planned for this development. Refer
where the water is required to sustain the ecology and SBSWMP.
hydrology of downstream systems
(environmental flows); AND
O5 Within the Shire Business Centre site, as shown on Map S5.1 No solution provided There is no on-site stormwater detention
SBC, on-site detention measures are contained within the planned for this development. Refer
developed areas of the site, clear of drainage lines and Open SBSWMP.
Space Precincts.
Run-off treatment S6.1 & S7.1 Development complies with Development complies with the water
O6 Run-off that leaves the site is treated so as not to the water quality standards in Table 2 of quality standards in Table 2 of the SEQ
adversely impact on the ecology and hydrology of the SEQ Regional Plan Implementation Regional Plan Implementation Guideline
downstream environmental flows; AND Guideline No. 7 for Water Sensitive Urban No. 7 for Water Sensitive Urban Design.
Design.
O7 Within the Shire Business Centre site, as shown on Map
SBC—
a) run-off treatment occurs within the site ; and
b) drainage lines are only used for final polishing
of run-off.
Town water supply connections S8.1 A suitable backflow prevention A suitable backflow prevention device
O8 Backflow devices or similar systems ensure water reuse device is installed to protect the potable will be installed to protect the potable
facilities have no impact on the quality of the town mains water within the reticulated water supply water within the reticulated water supply
water. in accordance with AS/NZS 3500:2003 in accordance with AS/NZS 3500:2003