Council archive · source document
0714 Noosa VIC Construction Set 12.06.08 · 132004.4078.09
Attached to the e-mail Owners Consent for Application for Minor Change 132004.4078.09.msg.
Attached to the e-mail Changes Application - Tourist Information Centre - 132004.4078.09.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
1 2 3 5
SLSC Redevelopment 4,800* 4,800 4,800* Boardwalk Existing Resort Development
*Grid Reference Dimensions
apply as viewed from Gridline D
Overall Height Line RL 11.40
Fall 51.9°
Fall 47.6°
Fall 53.9°
td td td
Fall 25.0°
9°
ll 31.
Fa
td
td Fall 60.5°
td
pc pc pc Fall 5°
pc
W.26 W.25 W.24 W.23 W.22 W.21 W.20
Base Of Upper Level Clerestory Joinery Line RL 5.40 fc
tc tc co
Joinery Line RL 5.20
Window Head Height tc tc
2400mm above FFL Public Beach Access Boardwalk
D.01 W.05 W.04
as per CD.08 and Scope of Works
Interactive Existing Rockwall With
Touchscreen 'Servery' W.03
New Timber Bench Seating
Na tur al Gr ou nd Lin As Per Specification
e Seat h: 450mm above FFL rb tc
Finished Floor Line RL 2.20 tc Netanya
1 2 3 5
South Elevation
Scale 1:100
5 3 2 1
5 4
4.800 3,487*
4,500 SLSC Redevelopment *Grid Reference Dimensions
apply as viewed from Gridline C
12,749
Overall Height Line RL 11.40
'Art-Wall' As Per Future Detail
Overall Height Line RL 10.80
ps ps
sl
W.40 W.39 W.38 W.37
5° W.40 W.39 W.38 W.37 W.36 W.35 W.34 W.33 W.32 W.31 W.30
fc pc
Base Of Upper Level Clerestory Joinery Line RL 6.20
tc Line Of Northern Elevation fc
Concealed By Surfclub
Head Height Underneath: 3000mm above FFL 2°
W.12 W.11
Spitter Pipe
Window Head Height Window Head Height RL 5.20 Future Fan Core Unit
Refer to Hydraulic
2400mm above FFL Documentation
tc Existing Rockwall With
tc New Timber Bench Seating
As Per Specification
Merchandise
W.07 D.07 rb rb
Finshed Floor Line RL 2.20 rb fc Finished Floor Line RL 2.20
Modified Ground Line
5 4 5 3 2 1
North Elevation North Elevation 2
Scale 1:100 Scale 1:100 For Construction
www.barkdesign.com.au
07 5471 0340
07 5471 0343
0418 876 394
0412 127 904
Email [email protected]
Australia 4567
Use figured dimensions
Noosa Heads
Bark Design Architects
Notes Rev. Date Description Rev. Date Description Project Drawing Title Project No.
in preference to scale. All
Bal-1
fc
Balustrade as per Scope of Works
Fibre Cement Sheeting
A 12.06.08 Issue for Construction dimensions to be verified
and checked on site. Noosa VIC North & South 0714
fx
gs
Fixed Glazing Panel
Gas Strut Hopper
These designs,drawings,
specifications and the
Elevations Drawing No.
lvr Louvre Gallery copyright thereof are the
o/x Fixed Glazing Panel/Opening Panel property of Bark Design
RAIA Member
28409
Noosa Heads CD.10
Steve Guthrie
pc Polycarbonate Multiwall Roof Sheeting Pty Ltd and must not be Noosa Council
PO Box 1355
Queensland
Lindy Atkin
Tourism Noosa
Telephone
ps Ply Sheeting used, retained or copied Architects
R
Revision
Facsimile
rb Rendered Blockwork without the written Registration No.
td TrimDek Ultra Roof Sheeting authority of Bark Design 3664 (LA)
Date June 2008 Scale 1:100 @ A2
A
Web
tc Timber Chamferboards Pty Ltd. 3668 (SG)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0714 Noosa VIC Construction Set 12.06.08.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.