Council archive · source document
0714 Noosa VIC Construction Set 12.06.08 · 132004.4078.09
Attached to the e-mail Owners Consent for Application for Minor Change 132004.4078.09.msg.
Attached to the e-mail Changes Application - Tourist Information Centre - 132004.4078.09.
Original PDF page 19, section 1. The text section number identifies this passage in the reader.
Location Name Display Area Display Area Service Entry Staff Room Manager's Office
7,200 3,750
2,510 1,945
3000 mm Above 2,440 2,510 1,945
Finished Floor Level Doors Stack Here
1,350
900 900
450 900
2400 mm Above
Finished Floor Level
Size (mm)
3,000
3,000
Note: All dimensions
2,400
2,400
2,400
are nominal only and must
be confirmed on site
prior to commencement
of fabrication and
construction
Item Name D.01 D.02 D.03 D.04 D.05
Overall Size: 3000mm x 7200mm Overall Size: 3000mm x 3750mm Overall Size: 2400mm x 900mm
Description Configuration: 03 Panels, Surface Slider Configuration: Surface Slider and Fixed Panel Configuration: Single Leaf - Swing Overall Size: 2400mm x 1350mm Overall Size: 2400mm x 900mm
Construction: Hardwood Timber Construction: Hardwood Timber Construction: Steel Framed - Solid Timber Core Configuration: Double Leaf - Swing Configuration: Single Leaf - Swing
Finish: Penetrative Oil Finish: Penetrative Oil Finish: Paint Finish Construction: Timber Framed - Hollow Core Construction: Timber Framed - Hollow Core
Glazing: Clear Float Glazing: Clear Float Glazing: Nil Finish: Paint Finish Finish: Paint Finish
Screens: Nil Screens: Nil Screens: Nil Glazing: Nil Glazing: Nil
Hardware: Flush Pulls - Internal Locking Only Hardware: Flush Pulls - Internal Locking Only Hardware: Lever Handle with Key Lock Hardware: Lever Handle Hardware: Lever Handle with Key Lock
Weather Seals: As Required Weather Seals: As Required Weather Seals: As Required Weather Seals: Not Required Weather Seals: Not Required
Door Leaf to be rebated.
Notes Flush Bolt into Overhead Sill
Location Name VIC WC Staff Room Acc. WC Male Urinal Male WC Female WC Female WC Public Amenities Gate
1,600
900 2,400 42x19mm
Timber
817
2400 mm Above 850 750 750 750 750 Battens With
Finished Floor Level
42mm Gap
42x19mm
793
Timber
Size (mm)
2,871
Battens With
19mm Gap
2,400
2,400
1,950
1,950
1,950
1,950
1,950
2,100
2,100
2,100
2,100
2,100
180x270mm 180x180mm 180x180mm 180x180mm 180x180mm
Note: All dimensions 180x270mm Facemounted Facemounted Facemounted Facemounted Facemounted 42x19mm
are nominal only and must Facemounted Access Signage Access Signage Access Signage Access Signage Access Signage Timber
1,261
be confirmed on site Access Signage Plate Plate Plate Plate Plate Battens With
prior to commencement Plate As per Scope of As per Scope of As per Scope of As per Scope of As per Scope of 42mm Gap
of fabrication and As per Scope of Works - Access Works - Access Works - Access Works - Access Works - Access
construction Works - Access Requirements Requirements Requirements Requirements Requirements
150
150
150
150
150
Requirements
Item Name D.06 D.07 D.08 D.09 D.10 D.11 D.12 G.01
Description
Overall Size: 2400mm x 900mm Overall Size: 2400mm x 2400mm Overall Size: 2100mm x 850mm Overall Size: 2100mm x 750mm Overall Size: 2100mm x 750mm Overall Size: 2100mm x 750mm Overall Size: 2100mm x 750mm Overall Size: 2871mm x 1600mm
Configuration: Single Leaf - Swing Configuration: 02 Leaf Surface Slider Configuration: Single Leaf - Swing Configuration: Single Leaf - Swing Configuration: Single Leaf - Swing Configuration: Single Leaf - Swing Configuration: Single Leaf - Swing Configuration: Single Leaf - Swing
Construction: Timber Framed - Hollow Core Construction: Extruded Aluminium Construction: Compressed FC Partitioning System Construction: Compressed FC Partitioning System Construction: Compressed FC Partitioning System Construction: Compressed FC Partitioning System Construction: Compressed FC Partitioning System Construction: Timber Battens on 50mm SHS Frame
Finish: Paint Finish Finish: Clear Anodised Finish: Paint Finish Finish: Paint Finish Finish: Paint Finish Finish: Paint Finish Finish: Paint Finish Finish: Paint Finish
Glazing: Nil Glazing: Clear Float Glazing: Nil Glazing: Nil Glazing: Nil Glazing: Nil Glazing: Nil Glazing: Nil
Hardware: Lever Handle with Privacy Set Screens: Nil Screens: Nil Screens: Nil Screens: Nil Screens: Nil Screens: Nil Screens: Nil
& Automatic Closer Hardware: Flush Pulls with Internal Lock Only Hardware: Indicator Bolt with External Key Lock Hardware: Indicator Bolt with External Key Lock Hardware: Indicator Bolt with External Key Lock Hardware: Indicator Bolt with External Key Lock Hardware: Indicator Bolt with External Key Lock Hardware: Hinged, Padlockable
Weather Seals: Not Required Weather Seals: As Required & Automatic Closer & Automatic Closer & Automatic Closer & Automatic Closer & Automatic Closer
Notes
Notes to Window and Door Schedule Shop Drawings:
- All aluminium frames to be select silver anodised aluminium to be installed to Provide Shop Drawings showing the following information
the manufacturers' specifications and details for particular cyclone wind terrain where appropriate to the items:
category. Layout (sectional plan and elevation of complete assembly)
Certification is required for compliance with wind pressures and waterproofing Full size section of members.
for the locale. Methods of assembly, type and location of exposed screws.
- All windows and doors to be on square set plasterboard reveals internally Methods of glazing.
- Sizes are nominal opening sizes only and openings are to be measured on Methods of installation, including fixings, anchorage,
site prior to manufacture. chalking, flashings.
Any discrepancies to be brought to the attention of Bark Design Architects at Provision for expansion (thermal).
that time. Junctions and trim to adjoining surfaces.
- All operational, opening and locking hardware and door and window furniture Fittings and accessories.
to be provided by the sub-contractor and approved by Bark Design. Hardware Sealant: Submit manufacturer's product specifications,
and Keying as scheduled handling, installation / curing instructions, and performance
All hinges to be stainless steel. tested data sheets for each elastomeric product required.
- All operable windows to be pre-hung in frames with hardware and locks
provided.
- No manufacturers' logos or stickers on any part of window or door panels.
- All Louvre windows to contain full Louvre blades (no fixed or 'make-up' panels).
- All louvres to be fully operable Insect screens shall not impede
Louvre blades from opening to full extent.
For Construction
www.barkdesign.com.au
07 5471 0340
07 5471 0343
0418 876 394
0412 127 904
Email [email protected]
Australia 4567
Use figured dimensions
Noosa Heads
Bark Design Architects
Notes Rev. Date Description Rev. Date Description Project Drawing Title Project No.
in preference to scale. All
Legend
x - Open
A 12.06.08 Issue for Construction dimensions to be verified
and checked on site. Noosa VIC Door Schedule1 0714
fg - Fixed These designs,drawings,
specifications and the
& Notes Drawing No.
cl - Clear copyright thereof are the
al - Aluminium property of Bark Design
RAIA Member
28409
Noosa Heads CD.18
Steve Guthrie
Pty Ltd and must not be Noosa Council
PO Box 1355
ob - Translucent, 'Matelux' Glass
Queensland
Lindy Atkin
Tourism Noosa
Telephone
used, retained or copied Architects
R
Revision
Facsimile
t - Timber without the written Registration No.
authority of Bark Design 3664 (LA)
Date June 2008 Scale 1:50 @ A2
A
Web
Pty Ltd. 3668 (SG)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0714 Noosa VIC Construction Set 12.06.08.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.