Appendix D Code Assessment · MCU16/0099.01
Division 9 — Natural Hazards Overlays Code
Table 4 Specific outcomes for the natural hazards overlay code
Specific outcomes Acceptable solutions Comments
(if accepted development)
Probable solutions
(if code assessment)
Effects of use
General S1.1 The proposed development is not Complies with S1.1
O1 Development is located to ensure it does not located in a landslide hazard area as indicated The proposed access and power installation to the
compromise the safety of people, property or on Overlay Maps OM1.3-OM9.313; approved facility are not proposed within areas of
hazardous materials manufactured or stored in bulk landslide hazard and will therefore not compromise
by increasing risk of landslide; OR the safety of people, property, or hazardous
materials.
AND S1.2 The development site is not subject to
landslide, either internally or from sloping land Complies with S1.2
O2 Development, including access ways is above the site e.g. slopes are less than 1 in The proposed access and power installation to the
designed and constructed to— 10 (10%) approved facility are not subject to landslide as the
minimise impacts on the natural landform; slopes in the subject area are less than 10%.
minimise risk to people and property from AND
landslide; S1.3 is not applicable
S1.3 Development, including necessary The proposal is not located within Precinct F.
avoid any potential instability and associated earthworks within Precinct F of the Noosa
problems, including long term stability of the Springs site, improves the stability of any non-
site and long-term stability of the development. Complies with O2
natural landform so it is not at risk from
The proposed access will have minimal impact on
landslide either on the site or from sloping land
natural landform as only a gravel upgrade is
above the site.
required to provide safe all-weather access for
construction and maintenance vehicles. The
S2.1 No solution provided
proposed power will be installed underground and
will have no impact on landform. Both the proposed
access and power installation to the approved
facility will not increase the risk to people and
property from the original approved routes.
Protection of Infrastructure and Community S3.1 Community Uses and Infrastructure Uses O3 is not applicable
Uses are not located in a landslide hazard area as The proposal does not involve a community use or
O3 Community Uses and Infrastructure Uses, indicated on Overlay Maps OM1.3- OM9.3; an infrastructure use.
Project 226420 File Appendix D – Code Assessment 2019-12-10 Revision 2 Page 25