                 Specific outcomes                         Probable solutions (if code assessment)                                  Comments
Safety and security                                      S5.1   For Installations and Towers—the use is       Complies with O5
O5     Infrastructure Uses are secure and potential      fenced with security fencing;                        The proposed powerline infrastructure will be
impacts from vandalism are minimised.                                                                         located underground and will therefore not be
                                                         AND                                                  impacted by potential vandalism.

                                                         S5.2     For other Infrastructure Uses—no
                                                         probable solution
Artificial lighting                                      S6.1     Lighting associated with the use is         O6 is not applicable
O6       The generation of spill light by development,   designed, installed, operated and maintained in      No artificial lighting is proposed as part of this
which gives rise to annoyance, discomfort, distraction   accordance with Section 3 of AS4282 The              application.
or a reduction in the ability to see essential           Control of the Obtrusive Effects of Outdoor
information, is avoided.                                 Lighting.
Mechanical plant and equipment                           S7.1     Plant and equipment are—                    O7 is not applicable
O7       Mechanical plant and equipment                        located more than 2m from any property         No permanent plant or equipment are proposed as
(including air conditioning equipment) are—                    boundary; and                                  part of this application.
       positioned to minimise adverse impacts on the           screened by dense vegetation or fencing
       amenity of any residential premises;                    (i.e. 1.5m wide vegetated buffer area);
     designed and positioned to visually integrate       OR
     with the building and roof design; and
     appropriately screened.                             S7.2     Plant and equipment are located within
                                                         a building.
Environment & heritage values                            No solution provided                                 Complies with O8
O8     There are no significant adverse effects on the                                                        The proposed access track, powerline infrastructure
biodiversity, natural vegetation, native wildlife,                                                            and tree clearing that is the subject of this
habitats, landscape quality, water quality or heritage   Editor’s Note:                                       application will not result in adverse impacts on
values, including those related to—                      PSP24 – Effluent Disposal details requirements       biodiversity, natural vegetation, native wildlife,
      changes to natural drainage;                       for the design and siting of effluent disposal       habitats, landscape quality, water quality or
     disturbance to any of the wetland                   systems where located outside a sewerage             heritage. Only three small trees are to be removed
                                                         service area.                                        to establish access. No vegetation disturbance or
     systems;
                                                         Compliance with PSP24 will be considered as          removal will occur as a result of the power
     management of landslide and fire risk;              part of Council’s assessment of the plumbing         installation.
     erosion and the transport of sediments off- site;   and drainage application
     unmanaged public access;
     effluent disposal;



                                                                                         Project 226420 File Appendix D – Code Assessment 2019-12-10 Revision 2 Page 36

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix D Code Assessment.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.