Council archive · source document
Appendix D Code Assessment · MCU16/0099.01
Specific Outcomes Probable solutions Comments
S8.3 Car parking and manoeuvring areas are
constructed at a level that permits the parking
area to drain from the site by gravity means,
without the need for mechanical pumping; or
S8.4 Basements for residential uses have
flood immunity above the 1%AEP defined flood
event where alternative means to mechanical
pumping are used to achieve such immunity; or
S8.5 Basements for non-residential uses
have flood immunity above the 1%AEP defined
flood event that may be achieved by means of
mechanical pumping only where the mechanical
feature is installed with adequate holding tanks
and an alternative back up power source.
Roof form S9.1 The main roof of the building has a roof O9 is not applicable
O9 Rooflines— pitch no less than 5 degrees and has minimum The proposed changes outlined in this change
contribute positively to the local skyline; 600mm eaves to at least 75% of the perimeter of application do not involve any new buildings or
complement the character of the locality; the building; structures and do not involve roofline design.
are articulated, pitched or skillion; AND
avoid low pitched (e.g. less than 5 degrees) or
box profiles/parapets; S9.2 Buildings and structures do not include
do not create opportunities for residents to roof top terraces.
overlook the private open space areas of
neighbouring properties.
Materials and finishes S10.1 Buildings— O10 is not applicable
O10 Buildings and other structures use materials use a mix of lightweight and textured The proposed changes outlined in this change
and finishes that complement the rural character and external building materials, including application do not involve any new buildings or
integrate with the surrounding natural landscape timber, corrugated iron, steel and structures.
weatherboard; or
Project 226420 File Appendix D – Code Assessment 2019-12-10 Revision 2 Page 5