dp dp
1 Electrical Plan
dp
Not to Scale
dp
dp
ex
dp dp
t
t
dp
tv
u
tv
u
u
dp
dp
tv t
dp
dp
t
dp
W D
u
dp dp
dp
dp
dp
dp
HWS
ELECTRICAL LEGEND NOTES
ALL SMOKE ALARMS ARE TO BE
PHOTOELECTRIC TYPE COMPLYING WITH
QTY QTY QTY AS3786 - 2014
5 NOTES
SINGLE GPO POINT 0 DOUBLE PARAFLOOD LIGHT
8 CEILING FAN 3 BLADE PROVIDE ENERGY EFFICIENT LIGHTING TO
80% OF TOTAL FLOOR AREA AS PER
40 DOUBLE GPO POINT 4 IXL LIGHT SUSTAINABLE HOUSING REQUIREMENTS. 15 Ross Cresent, Sunshine Beach
ELECTRICAL POWER POINT IN CEILING FOR
u 0 CEILING FAN/LIGHT 3 BLADE Queensland, 4567
dp
3 0 ARIAL BOOSTER IF REQUIRED
UNDER BENCH GPO POINT EXTERNAL BUNKER @ 2400
The designs and drawings shown on these plans are copyrighted
ELECTRICAL NOTES and remain the property of Mark Bain Constructions,
u SINGLE BATTEN FLUORESENT
1 DOUBLE GPO POINT 3 1. ALL MATERIALS AND WORKMANSHIP Unauthorized copy/distribution of these plans is prohibited.
LIGHT WITH DIFFUSER
GAS
2 CEILING FAN STAINLESS 3 BLADE SHALL BE IN ACCORDANCE WITH AS 3000.
ex DOUBLE BATTEN FLUORESENT 2. ALL WORK SHALL BE PERFORMED BY Client Name
0 EXTERNAL GPO POINT 0 LICENSED ELECTRICAL TECHNICIANS.
LIGHT WITH DIFFUSER Mark Bain Constructions
0 FO FIBRE OPTIC 3. ALL CONDUITS AND WIRING SHALL BE
ex EXTERNAL DOUBLE Project Name
1 0 BONDI ENTRY LIGHT @ 2400 CONCEALED, SIZES SHALL BE IN ACCORDANCE
GPO POINT 0 A/C A/C UNIT WITH AS 3000
4. CONFIRM THE LOCATION OF ALL ITEMS ON
Proposed New Residence
0 PENDANT LIGHT (SEE SPEC.) 0 EXHAUST FAN SITE WITH THE OWNER 95 Hollett Road, Noosaville
1 HWS HOT WATER SYSTEM
5. LIGHT SWITCHES @ 1070 ABOVE FLOOR Qld, 4565
ELEC
LOW VOLTAGE
0 7 SMOKE ALARM 1 GAS GAS BOTTLES 6. NORMAL GPO @ 300 ABOVE FLOOR.
DOWN LIGHT
dp
7. RANGEHOOD GPO @ 1800 ABOVE FLOOR
ENERGY EFFICIENT t 1 METER BOX 8. FRIDGE GPO @ 1600 ABOVE FLOOR.
62 4 PHONE/DATA POINT ELEC Drawing Title:
DOWN LIGHT 9. DISHWASHER GPO @ 450 ABOVE FLOOR
AND IN CUPBOARD
0
OYSTER LIGHT
(Circular Fluro)
3
tv
TV JACK
DUCTED AIR CONDITIONING 10. W/MACHINE GPO @ 1200 ABOVE FLOOR ELECTRICAL PLAN
Positions TBC 11. GARAGE GPO ON CEILING.
11 2 WAY LIGHT SWITCH 20 SINGLE LIGHT SWITCH 12. GPO ABOVE BENCHES @100 ABOVE BENCHES Scale:
Date: 15.10.2018
As Shown @ A3 Size
Status: CD Checked By: NPH
Project No: Drawing No.:
HRN095 CD09
Plot Date: 15/10/2018
See the original
The page text is free to read. Viewing or downloading an original file needs an account.