Original source · versioned page text
David Moore Noise report
Attached to the e-mail MCU16/0137 Response to NC Information request - 5/8 Selkirk Drve Noosaville.
Gelherdt No 2 Pty Ltd Desk Top Environmental Noise Level Impact Assessment of Proposed Fitness Centre, 5/8 Selkirk Drive, Noosaville Page 9 of 12 Time Varying Noise car driving: 50 dB(A) LAeq,adj,T @ 8 metres – 21 (90 m separation distance) – 12 (intervening commercial/industrial building) = 17 dB(A) LAeq,adj,T; car door closing: 62 dB(A) LAeq,adj,T @ 8 metres – 21(90 m separation distance) – 12 (intervening commercial/industrial building) = 29 dB(A) LAeq,adj,T; car engine starting: 62 dB(A) LAeq,adj,T @ 8 metres – 21(90 m separation distance) – 12 (intervening commercial/industrial building) = 29 dB(A) LAeq,adj,T; people laughing, talking: 62 dB(A) LAeq,adj,T @ 8 metres – 21(90 m separation distance) – 12 (intervening commercial/industrial building) = 29 dB(A) LAeq,adj,T; amplified music: 85 to 90 dB(A) LAeq,adj,T @ 3 metres – 24 (45 m separation distance) – 25 (inside to outside building, external openings closed) = 36 to 41 dB(A) LAeq,adj,T; amplified voice: 85 to 90 dB(A) LAeq,adj,T @ 3 metres – 24 (45 m separation distance) – 25 (inside to outside building, external openings closed) = 36 to 41 dB(A) LAeq,adj,T. All of the above source noise levels comply (amplified music and amplified voice maximum permitted volume is 89 dB(A) LAeq,adj,T) with the evening noise limits at the closest residence on the opposite side of Walter Hay Drive. For noise from within the fitness centre – amplified music and amplified voice, this assumes that all external openings are closed. As the fitness centre will be fully airconditioned there will be no need to open any external doors or windows, albeit that it would appear that all windows are fixed (unopenable) glazing. With respect to the sliding glass doors to the two mezzanine balconies, these are both off office space and only accessible to fitness centre staff. These sliding glass doors must remain closed whenever there is any noise generating activity within the fitness centre. It should also be noted that one of the main potential sources of amplified music/voice is group fitness activities, and this is conducted in a separate room with further noise attenuation to the closest residences, as it is completely walled off from all other parts of the fitness centre (and this additional acoustic isolation has net been accounted for in the above calculations). Night-time During the night-time (2200 to 0700 hours) the estimated lowest background sound level at the closest residences is 40 dB(A), with associated noise limits of: steady sound: 30 dB(A) LA90,T; time varying sound: 35 dB(A) LAeq,adj,T. At the closest residences on the opposite side of Walter Hay Drive the noise level impact of the proposed fitness centre will be: Continuous Noise airconditioning unit: 68 dB(A) LWA + 5 (estimated 3 units, all operating) – 41 (45 m separation distance) – 5 (intervening acoustic barrier) = 27 dB(A) LA90,T; David Moore & Associates Pty Ltd Our reference: R17015/D3218/Rev.0/1.03.17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.