Original source · versioned page text
2018-11-12 General Committee Meeting Notes
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
RECOMMENDATIONS ONLY – NOT THE FINAL DECISION OF COUNCIL
GENERAL COMMITTEE MEETING 12 NOVEMBER 2018
90. The courtyard of the manager’s unit situated at 106 Pacific Avenue must not be
used between the hours of 9.00pm and 6.00am.
91. The pool and associated deck area must not be used between the hours of
9.00pm and 7.00am.
Outdoor Lighting Devices
92. Lighting associated with the use must be designed, sited, installed and tested to
comply with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of
the obtrusive effects of outdoor lighting” using a control level of 1.
93. Certification must be submitted to Council from a qualified person which
certifies that all outdoor lighting devices comply with the requirements of this
Decision Notice at the time of commissioning.
For the purpose of certifying outdoor lighting devices for the development, a
qualified person is:
a. Registered Professional Engineer of Queensland;
b. an environmental or electrical design consultant with a minimum of 3
years current experience in the field of outdoor lighting.
WASTE
94. The developer must provide waste storage and disposal facilities in accordance
with Planning Scheme Policy No. 9 "Waste Management Multi-Dwellings and
Commercial and Industrial Premises". The facilities must include an external
impervious area correctly sized for all refuse and recycling containers and
suitably screened from public places and neighbouring properties. A bin wash
area is required with a cold-water tap, hose and drain outlet connected to
sewer, via a bucket trap. The drain outlet must be designed to prevent storm
water entry to the sewerage system. This can be achieved with a nib wall
50mm high and up to 700mm x 700mm wide (max 0.5m2) , or alternatively the
waste area can be roofed, or any other design approved by Council.
95. Refuse containers must be provided in accordance with the requirements of the
Environmental Protection (Interim Waste) Regulation 1996 and (Waste
Management) Regulation 2000, for the storage and collection of refuse.
96. Bins must be provided throughout the site to reduce littering. All bins provided
must be for refuse and recycling and be decanted into the bulk bins by the site
operators.
ENGINEERING
Site Access and Driveways
97. A sealed access driveway must be provided from Pacific Avenue to all parking
and manoeuvring areas of the development. The new works proposed to
access No 106 must be undertaken in accordance with an Operational Works
approval and must include in particular:
a. a driveway crossover generally in accordance with Council’s Standard
Drawings RS-051 and the associated addendum
Page 11 of 13