Original source · versioned page text
2 David Low Way - Attachment 6 - UXO Assessment - OPEC
Attached to the e-mail Reconfiguration of a Lot (1 lot into 6) - RAL17/0501.
OPEC - 2 David Low Highway, Castaways Beach
Rev 02 – AFU – 10 Aug 2017
RECOMMENDED ACTIONS
The following summarises recommended mitigations that should be considered for development of
this Site:
Conduct general UXO education and awareness for personnel working at the Site.
Develop ‘Safe Working Procedures’ for work undertaken to include, for example:
o Restrictions on entry into specific areas (e.g. defining ‘No Go’ areas);
o Protocols to ensure that the number of personnel entering or working near UXO areas
are kept to the minimum necessary to effectively perform the work;
o Definition of safe/unsafe areas, safety distances, ‘Wait Times’, etc;
o Actions to be taken if UXO encountered or observed;
o Medical Response Plan for UXO-related injuries; and
o Reporting and internal investigation requirements.
Undertake 100% surface visual/detector-assisted UXO search to identify any surface or
shallow buried EO items.
Undertake 100% UXO investigation/remediation work of all areas where ground-intrusive
work is planned
Review risk assessment(s) as new data from field work comes to hand or when EO items are
found/reported. Ongoing re-evaluation of risks is a key aspect of an effective risk
management system.
------------------------- END OF DOCUMENT -------------------------
For use only in relation to the specified project
© 2017 Copyright BOZ Technical Services Pty Ltd Page 22 of 22